• 제목/요약/키워드: Heating methods

검색결과 1,007건 처리시간 0.028초

중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구 (A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.

  • PDF

The Electronic Laser Interferometry and Laser Heating Method for Residual Stress Determination

  • Kim, Koung-Suk;Kang, Young-June;Rho, Kyung-Wan;Ryu, Weon-Jae
    • Journal of Mechanical Science and Technology
    • /
    • 제14권7호
    • /
    • pp.715-721
    • /
    • 2000
  • Residual stress is one of the causes which makes defects in engineering components and materials. These residual stresses can occur in many engineering structures and can sometimes lead to premature failures. There are commonly used methods by which residual stresses are currently measured. But these methods have a little damage and other problems; therefore, a new experimental technique has been devised to measure residual stress in materials with a combination of electronic laser interferometry, laser heating and finite element method. The electronic laser interferometer measures in-plane deformations while the laser heating and cooling provides for very localized stress relief. FEM is used for determining the heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heat-up and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, the ambiguity problem for the fringe patterns has solved by a phase shifting method.

  • PDF

Equivalent Point Method의 일반적 이용을 위한 연구 (Study on the Generalization of the Equivalent Point Method for Thermal Evaluation)

  • 임종환
    • 한국식품과학회지
    • /
    • 제22권5호
    • /
    • pp.575-581
    • /
    • 1990
  • 일정한 열처리 공정에 대해 Equivalent point가 존재함을 이상적인 두가지의 직접가열곡선 즉, $120^{\circ}C$에서 10분간 $135^{\circ}C$에서 10초간의 등온가열 곡선을 이용하여 예시하였다. 이러한 조건하에서 Arrhe nius model을 적용한 경우 임의의 Ea-값을 사용하여 G-값을 결정하고 Bigelow model을 적용한 경우, 임의의 z-값을 사용하여 F-값을 결정하였다. 이들 값을 사용하여 Equivalent time과 Equivalent Temperature를 두가지 방법 즉, 직교좌표법과 회기분석법에 의해 결정하였다. 이들 두 방법에 의해 결정된 Equivalent Point는 서로 일치하였으며 각각의 값은 초기에 가정했던 직접가열곡선의 가열시간 및 온도와 일치하였다.

  • PDF

동결건조한 두유 분말의 품질 특성 (Quality Characteristics of Freeze-Dried Soymilk Powder)

  • 김용선
    • 한국식품영양학회지
    • /
    • 제27권1호
    • /
    • pp.89-98
    • /
    • 2014
  • In this study, soybean is used to produce soymilk according to various extracting methods and heating time. Specifically, the soy slurry is being filtered before being heated, or heated before being filtered. Following that the soymilk produced is freeze-dried to be powdered, and then, the quality characteristics of the powdered soymilk are mutually compared to determine the applicability of various food additives. The freeze-dried soymilk powder shows 2.03~6.35% of moisture content, and in terms of unit quantity, retained more proteins, which suggests that the ratio of protein extraction is higher than any other nutrients. Accordingly, the protein coefficient is significantly higher in soymilk powder being heated and processed than in raw soybeans. In particular, protein coefficient is the highest in the soymilk which is heated for 20 minutes before being filtered (SHBF20). The longer the heating time was, the trypsin inhibitor (TI) tended to be far less active. Such an inactivation seems to be more apparent in the "SHAF" soymilk powder than "SHBF" soymilk powder. Because protein had to be denaturated by heating for soymilk, the nitrogen solubility index (NSI) of soymilk powder is decreased considerably, while the protein digestibility, water absorption, emulsification and foaming activity all increase. Oil absorption tends to decrease slightly. As discussed above, the soymilk heated for 10 minutes after being filtered (SHAF10) and the soymilk heated for 20 minutes before being filtered (SHBF20) show optimum processing conditions for soymilk powder.

동부 앙금 호화액의 흐름 성질 (Flow Properties of Gelatinized Cowpea Flour Dispersion)

  • 이애랑;김성곤;이신영
    • 한국식품영양과학회지
    • /
    • 제22권2호
    • /
    • pp.181-185
    • /
    • 1993
  • 동부앙금(6~9%)을 연속가열법과 순간가열법으로 각 온도(80, 85, 90, 95$^{\circ}C$)에 도달시키고 20분간 유지시킨 다음 호화액의 흐름성질을 회전점도계를 이용하여 회전속도 6~180rpm, 측정온도 6$0^{\circ}C$의 조건에서 분석하였다. 호화액은 항복응력을 가진 의가소성 유체의 성질을 보였고 각 전단속도에서의 전단응력값은 순간 가열호화액이 연속가열호화액 보다 컸다. 순간 가열호화액은 농도와 가열온도에 관계없이 연속 가열호화액보다 항복응력과 점조도 지수값이 컸고 흐름지수 값은 작았다. 점조도 지수의 대수값은 농도와 가열온도와 정의 상관관계 (p<0.05)를 보였다. 동일한 농도에서 순간 가열호화액은 연속 가열호화액보다 가열온도에 따른 점조도 지수의 대수값의 증가 속도가 컸다.

  • PDF

온열환경과 인삼(Panax Ginseng)이 Rat의 체온, 혈액학적 변화, 면역반응에 미치는 영향 (Effect of Heating Condition and Panax Ginseng on Body Temperature, Hematological Changes, and Immune Response in Rat)

  • 이서라;이인희;김민지;류재환
    • 대한한방내과학회지
    • /
    • 제35권1호
    • /
    • pp.59-69
    • /
    • 2014
  • Objectives : This study was designed to test the effect of heating condition and Panax ginseng on body temperature, hematologicala changes, and immune response. Methods : The extract from Panax ginseng was made by the pharmacy department of Kyung Hee Oriental Medical Hospital. The animals were divided into four groups; control, room temperature Panax ginseng (G), $28^{\circ}C$ heating, and $28^{\circ}C$ heating Panax ginseng (heating G). Each group has 8 Sprague-Dawley rats. We measured body weight & temperature twice a week. After 2 weeks of experiment, serum lipid level, WBC, differential count, lymphocyte proliferation and immune cytokine concentration were measured. Results : 1. Simultaneous application of heating condition and Panax ginseng induced decreased body weight and increased body temperature. 2. Simultaneous application of heating condition and Panax ginseng induced decreased AST, ALT and BUN. 3. Simultaneous application of heating condition and Panax ginseng tended to decrease TNF-${\alpha}$ concentration, while application of room temperature and Panax ginseng tended to increase TNF-${\alpha}$ concentration. Conclusions : Simultaneous application of heating condition and Panax ginseng decreseas body weight, increases, body temperature and has a tendency to decrease TNF-${\alpha}$ concentration.

마이크로파 및 기존 가열 방법에 의한 제올라이트 NaY의 합성 (Synthesis of NaY Zeolites by Microwave and Conventional Heating)

  • 최고열
    • 공업화학
    • /
    • 제18권4호
    • /
    • pp.344-349
    • /
    • 2007
  • 마이크로파 가열(microwave heating)에 의하여 제올라이트 NaY를 합성하였으며, 그 결과를 기존의 가열 방법(conventional heating)에 의하여 합성한 결과와 비교하였다. 같은 승온 속도를 사용하였을 때는 마이크로파에 의하여 가열하였을 때가 기존의 가열 방법에 비하여 NaY 결정 생성의 유도 기간(induction period)이 감소하였으며 결정의 생성 속도가 증가하였다. 또한 마이크로파의 사용 여부와 관계없이 승온 속도가 빠를 때도 유도 기간이 감소하고 결정 생성 속도가 증가하였다. 빠른 승온 속도에서 합성하였을 때 최종 결정의 크기가 크며, 이는 마이크로파의 사용에 의하여 더욱 증가하였다. 빠른 승온 속도에서는 반응 시간이 짧아져서 NaY의 합성에 소모되는 에너지 소모량은 감소하였다. 본 연구의 조건에서는 에틸렌글리 콜조(ethylene glycol bath)를 사용한 기존 가열 방법에서의 에너지 소모량이 마이크로파 가열보다 적게 나타났는데, 이는 마이크로파 에너지를 사용하는 것이 항상 효율적인 것만은 아니라는 것을 말해준다. 그러나 승온 속도를 적절히 조절하면 마이크로파 가열에 의해서 에너지 면에서 보다 효율적으로 NaY를 합성할 수 있다는 것을 알 수 있었다

난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode)

  • 강훈;정현준;주영주;김용찬;최종민
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

FTA를 이용한 볼트 유도가열시스템의 고장 및 전기화재 분석 (Analysis of Failure and Electrical Fire for Bolt Induction Heating System Using FTA)

  • 김두현;김성철;엄한얼;강문수;정천기
    • 한국안전학회지
    • /
    • 제36권4호
    • /
    • pp.12-19
    • /
    • 2021
  • This paper presents a safety assessment method for FTA-based induction heating systems; the failures and causes of electrical fire are first analyzed for each part and module qualitatively, and methods to manage high probabilities of failure and electrical fire are considered, thereby improving the reliability of the induction heating system. The cumulative importance value (ACC) of the minimal cut set is drawn by setting failure as the top event, and STACK and SMPS are observed to account for about 70% of the induction heating system failures. Thus, intensively managing the basic events contained in the minimal cut set of failures for STACK and SMPS is expected to provide effective and stable operation of the induction heating system. When electrical fire is set as the top event, the STACK percentage is 90%. Accordingly, the current IGBT is changed to a FET to increase the applied voltage and prevent induction heating system failure, and a heat sink plane is installed to prevent FET heating caused by switching, thereby preventing an electrical fire. By classifying the parts and modules of the induction heating system in detail and by applying FTA based on actual failure rates and relevant data, more practical and reasonable results may be expected. Hence, continuous research must be conducted to ensure safety when using induction heating systems.

공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구 (A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings)

  • 김오봉;이미경;김광우;여명석
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.