• Title/Summary/Keyword: Heating methods

Search Result 1,007, Processing Time 0.022 seconds

A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System (중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구)

  • Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.

  • PDF

The Electronic Laser Interferometry and Laser Heating Method for Residual Stress Determination

  • Kim, Koung-Suk;Kang, Young-June;Rho, Kyung-Wan;Ryu, Weon-Jae
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.7
    • /
    • pp.715-721
    • /
    • 2000
  • Residual stress is one of the causes which makes defects in engineering components and materials. These residual stresses can occur in many engineering structures and can sometimes lead to premature failures. There are commonly used methods by which residual stresses are currently measured. But these methods have a little damage and other problems; therefore, a new experimental technique has been devised to measure residual stress in materials with a combination of electronic laser interferometry, laser heating and finite element method. The electronic laser interferometer measures in-plane deformations while the laser heating and cooling provides for very localized stress relief. FEM is used for determining the heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heat-up and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, the ambiguity problem for the fringe patterns has solved by a phase shifting method.

  • PDF

Study on the Generalization of the Equivalent Point Method for Thermal Evaluation (Equivalent Point Method의 일반적 이용을 위한 연구)

  • Rhim, Jong-Whan
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.575-581
    • /
    • 1990
  • The existence of the equivalent point for a thermal processing system was demonstrated using arbitrarily chosen ideal direct heating curves. i.e. isothermal heating curves at $120^{\circ}C$ for 10min and at $135^{\circ}C$ for 10sec. Under these conditions, G-values and F-values were calculated at various values of Ea- and z-values by applying the Arrhenius and the Bigelow models respectively. The equivalent time and equivalent temperature were determined by both line intersection and linear regression methods. The equivalent points estimated by both the line intersection and the linear regression methods were consistent and their values were the same as the heating time and temperature of the ideal direct heating curves.

  • PDF

Quality Characteristics of Freeze-Dried Soymilk Powder (동결건조한 두유 분말의 품질 특성)

  • Kim, Yong-Sun
    • The Korean Journal of Food And Nutrition
    • /
    • v.27 no.1
    • /
    • pp.89-98
    • /
    • 2014
  • In this study, soybean is used to produce soymilk according to various extracting methods and heating time. Specifically, the soy slurry is being filtered before being heated, or heated before being filtered. Following that the soymilk produced is freeze-dried to be powdered, and then, the quality characteristics of the powdered soymilk are mutually compared to determine the applicability of various food additives. The freeze-dried soymilk powder shows 2.03~6.35% of moisture content, and in terms of unit quantity, retained more proteins, which suggests that the ratio of protein extraction is higher than any other nutrients. Accordingly, the protein coefficient is significantly higher in soymilk powder being heated and processed than in raw soybeans. In particular, protein coefficient is the highest in the soymilk which is heated for 20 minutes before being filtered (SHBF20). The longer the heating time was, the trypsin inhibitor (TI) tended to be far less active. Such an inactivation seems to be more apparent in the "SHAF" soymilk powder than "SHBF" soymilk powder. Because protein had to be denaturated by heating for soymilk, the nitrogen solubility index (NSI) of soymilk powder is decreased considerably, while the protein digestibility, water absorption, emulsification and foaming activity all increase. Oil absorption tends to decrease slightly. As discussed above, the soymilk heated for 10 minutes after being filtered (SHAF10) and the soymilk heated for 20 minutes before being filtered (SHBF20) show optimum processing conditions for soymilk powder.

Flow Properties of Gelatinized Cowpea Flour Dispersion (동부 앙금 호화액의 흐름 성질)

  • 이애랑;김성곤;이신영
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.2
    • /
    • pp.181-185
    • /
    • 1993
  • The effects of concentrations (6~9%), heating temperatures (80, 85, 90 and 95$^{\circ}C$) and heating methods (continuous, method A and instantaneous, method B) on the flow properties of cowpea flour (air-dried sediment) at 6$0^{\circ}C$ were studied. The gelatinized cowpea flour dispersions by method B had higher values of yield stress and consistency index but lower value of flow behavior index compared to those values of method A. The log values of consistency index were positively correlated with the concentration and heating temperature for both methods. The rate of increase in the consistency index value by method B at the same concentration was greater in all heating temperatures than that by method A.

  • PDF

Effect of Heating Condition and Panax Ginseng on Body Temperature, Hematological Changes, and Immune Response in Rat (온열환경과 인삼(Panax Ginseng)이 Rat의 체온, 혈액학적 변화, 면역반응에 미치는 영향)

  • Yi, Seo-Ra;Lee, In-Hee;Kim, Min-Ji;Lew, Jae-Hwan
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.59-69
    • /
    • 2014
  • Objectives : This study was designed to test the effect of heating condition and Panax ginseng on body temperature, hematologicala changes, and immune response. Methods : The extract from Panax ginseng was made by the pharmacy department of Kyung Hee Oriental Medical Hospital. The animals were divided into four groups; control, room temperature Panax ginseng (G), $28^{\circ}C$ heating, and $28^{\circ}C$ heating Panax ginseng (heating G). Each group has 8 Sprague-Dawley rats. We measured body weight & temperature twice a week. After 2 weeks of experiment, serum lipid level, WBC, differential count, lymphocyte proliferation and immune cytokine concentration were measured. Results : 1. Simultaneous application of heating condition and Panax ginseng induced decreased body weight and increased body temperature. 2. Simultaneous application of heating condition and Panax ginseng induced decreased AST, ALT and BUN. 3. Simultaneous application of heating condition and Panax ginseng tended to decrease TNF-${\alpha}$ concentration, while application of room temperature and Panax ginseng tended to increase TNF-${\alpha}$ concentration. Conclusions : Simultaneous application of heating condition and Panax ginseng decreseas body weight, increases, body temperature and has a tendency to decrease TNF-${\alpha}$ concentration.

Synthesis of NaY Zeolites by Microwave and Conventional Heating (마이크로파 및 기존 가열 방법에 의한 제올라이트 NaY의 합성)

  • Choi, Ko-Yeol;Conner, W. Curtis
    • Applied Chemistry for Engineering
    • /
    • v.18 no.4
    • /
    • pp.344-349
    • /
    • 2007
  • NaY zeolites synthesized by microwave heating were compared with those obtained by conventional heating. When the same temperature increasing rates were adopted in both heating methods, the microwave heating shortened the induction period and enhanced the rate of crystallization of NaY zeolites compared with the conventional heating. Irrespective of microwave radiation, the fast temperature increasing rate also shortened the induction time and enhanced the crystallization of NaY zeolites. The crystal sizes of NaY zeolites were large under the fast temperature raise of the reaction mixture and became larger by microwave radiation. At the same time, the fast temperature increasing rate has reduced the energy consumption due to the fast completion of reaction during the synthesis of NaY zeolite. The energy consumption in the conventional ethylene glycol bath was lower than that in the microwave oven with the same temperature increasing rate in this study, which means that the energy efficiency is not always high in microwave heating. If the temperature increasing rate is carefully controlled, however, NaY zeolite can be produced with high energy efficiency in the microwave oven.

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode (난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Kang, Hoon;Jung, Hyen-Joon;Joo, Young-Ju;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

Analysis of Failure and Electrical Fire for Bolt Induction Heating System Using FTA (FTA를 이용한 볼트 유도가열시스템의 고장 및 전기화재 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Eom, Haneol;Kang, Moon-Soo;Jeong, Cheon-Kee
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.4
    • /
    • pp.12-19
    • /
    • 2021
  • This paper presents a safety assessment method for FTA-based induction heating systems; the failures and causes of electrical fire are first analyzed for each part and module qualitatively, and methods to manage high probabilities of failure and electrical fire are considered, thereby improving the reliability of the induction heating system. The cumulative importance value (ACC) of the minimal cut set is drawn by setting failure as the top event, and STACK and SMPS are observed to account for about 70% of the induction heating system failures. Thus, intensively managing the basic events contained in the minimal cut set of failures for STACK and SMPS is expected to provide effective and stable operation of the induction heating system. When electrical fire is set as the top event, the STACK percentage is 90%. Accordingly, the current IGBT is changed to a FET to increase the applied voltage and prevent induction heating system failure, and a heat sink plane is installed to prevent FET heating caused by switching, thereby preventing an electrical fire. By classifying the parts and modules of the induction heating system in detail and by applying FTA based on actual failure rates and relevant data, more practical and reasonable results may be expected. Hence, continuous research must be conducted to ensure safety when using induction heating systems.

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.