• Title/Summary/Keyword: Heating gun

Search Result 142, Processing Time 0.022 seconds

Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building (오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교)

  • Jung Gun-Joo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.

Design of High Frequency Casting Machine for Dental using Induction Heating System (유도가열 시스템을 적용한 치과용 고주파 주조기 설계)

  • Song, Seung-Gun;Lim, Sang-Kil;Lee, Sang-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.79-87
    • /
    • 2012
  • Currently, The method to produce a brewing body for dentistry supplementation water produces a brewing body by fabrication, burying and it is heat wish in city gas and oxygen. It uses an original judgment found airplane the brewing body uses a spring of the back wait that melting temperature dissolved various alloys in by a blow pipe, and to generate centrifugal force and produces it. In addition, because it uses preheating to dissolve an alloy in general, it is hard to regulate the appropriate melting temperature of the alloy and brewing time and generates a brewing defect hereby same as gas industry and pinhole and shows the defect of the supplementation thing due to the super-heating. In this paper, We developed the high induction heating system which it could set brewing time,temperature and had durability and security,by the kind of the alloy to produce a high quality prosthetic thing brewing body.

Hypersonic Aero-Heating Ground-Test Simulation Technique

  • Li, Ruiqu;Yao, Dapeng;Sha, Xinguo;Gong, Jian
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.50-53
    • /
    • 2015
  • It would encounter some complicated flow fields, such as transition, separation, reattachment and disturbances, in the hypersonic flight. Thus, it is difficult to theoretically analyze the hypersonic aerothermodynamics effects, so that the ground-test simulation is thought of as one of the most important methods to improve the understanding level of the hypersonic aerothermodynamics. However, the aero-heating tests could not simulate all aerodynamics and geometry parameters in the real flight due to the differences between the experimental environments supplied by the ground facilities and the flight, so that the feasible technique for the ground-test simulation of the hypersonic aerothermodynamics effects is required to be advanced. The key parameters that are especially required to simulate for aero-heating tests are analyzed and one detailed approach is suggested to perform the experimental investigation on the hypersonic aero-heating effects in the ground facilities in this paper, and the tests are performed in the FD-20 gun tunnel of CAAA (China Academy of Aerospace Aerodynamics) to give out the data which could be used to confirm the equation from the theoretical analysis.

A Study on the Algorithm for the Occupancy Inference in Residential Buildings using Indoor CO2 Concentration and PIR Signals (실내 CO2 농도와 PIR 신호를 활용한 주거건물의 재실 추정 알고리즘에 관한 연구)

  • Rhee, Kyu-Nam;Jung, Gun-Joo
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.113-119
    • /
    • 2018
  • Occupancy-based heating control is effective in reducing heating energy by preventing unnecessary heating during unoccupied period. Various technologies on detecting human occupancy have been developed using complicated machine learning algorithm and stochastic methodologies. This study aims at deriving low-cost and simple algorithm of occupancy inference that can be implemented to residential buildings. The core concept of the algorithm is to combine the occupancy probabilities based on indoor CO2 concentration and PIR(passive infrared) signals. The probability was estimated by applying different levels of decrement ratio depending on CO2 concentration change rate and aggregated PIR signals. The developed algorithm was validated by comparing the inference results with the occupancy schedule in a real residential building. The results showed that the inference algorithm can achieve the accuracy of 75~99%, which would be successfully implemented to the control of residential heating systems.

Analyses of Heating and Cooling load in Greenhouse of Protected Horticulture Complex in Taean (태안 시설원예단지의 온실 냉난방 부하 분석)

  • Suh, Won-Myung;Bae, Yong-Han;Heo, Hae-Jun;Kwak, Cheul-Soon;Lee, Suk-Gun;Lee, Jong-Won;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.45-52
    • /
    • 2009
  • This study was conducted in the process that the basic plan of the formation of the thermal energy complex in the Iwon reclaimed land of Taean was being made. Targeting for the large-sized greenhouse to be made in this area, it examined the cooling and heating load and the amount of ventilation, and also analyzed the economic efficiency of heating. The research results are as per the below: The minimum ambient temperature of this area was measured on January 7, 2001, which was $-18.7^{\circ}C$, and the maximum ambient temperature of this area was measured on July 24, 1994, which was $36.7^{\circ}C$. The maximum heating load was 39,011 MJ/h, but the date when the maximum heating load was not consistent with the date when the minimum temperature was measured. The maximum cooling load was 88,562MJ/h, It was approximately 2.3 times of the maximum heating load, which was measured at 14:00 hours on September 4, 2000. The maximum amount of ventilation heat was 138,639MJ/h. Assuming the rate of solar heat use as 10%, 20%, 50%, and 100%, the total sum of cost-benefit would be ₩-193,450,000, ₩-634,930,000, ₩-3,372,960,000, and ₩-9,850,420,000, respectively 20 years later. The break-even point of the geothermal heat pump would be about 4 years for 10% use, about 3 years for 20% or 50% use, and approximately 6 years for 100% use. It was found that 50% use would be most advantageous. In case two systems are combined, the break-even point will be 10 years, 8 years, and 11 years respectively.

The Two Cases Report of Bee Venom Injection on Patient with Low Back Pain Maintaining after Heating-Conduction Acupuncture Therapy (전열침 시술에 호전되지 않는 요통환자에 대한 봉독약침 치료 증례보고 2례)

  • Yeon, Chang-Ho;Park, Hyun-Gun;Yi, Woon-Sup;Kim, Jong-Yeon;Chung, Seok-Hee
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.7 no.2
    • /
    • pp.75-81
    • /
    • 2012
  • Objectives : According to previous reports, heating-conduction acupuncture treatment is very effective for sprain and strain of ligament. But there was no report about pain aggravation by heating-conduction acupuncture and relief from bee venom injection. In this article, we report two cases of pain aggravation by heating-conduction acupuncture treatment and relief from bee venom injection. Methods : We used heating-conduction acupuncture treatment on possible sprain of sacroiliac ligament diagnosed by physical examination. Outcomes were measured by Visual Analogue Scale(VAS), Range of Motion(ROM) and Belt test, Goldthwait test. Results : The patient has shown an aggravation on pain and ROM. And after we use subcutaneous bee venom injection, pain has relieved and ROM improved. Belt test, Goldthwait test also changed from positive to negative. Conclusions : In this report, we assured the effect of Bee venom injection. Further well-designed, controlled studies and more cases are needed to differentiate the indication of heating-conduction acupuncture and bee venom injection.

  • PDF

An Experimental Study on Heating Manufacture of Recycled Aggregate by Design of Experiment (실험계획법을 이용한 가열방식의 순환굵은골재 제조를 위한 실험적 연구)

  • Nam, Eun-Yong;Hwang, Sun-Bok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • The use of wasted concrete can settle the environmental pollution and shortage of natural aggregate. However, recycled aggregate includes substantial amount of cement paste, so that these aggregates are more porous, and less resistant to mechanical actions than natural aggregates. Recently, the new manufacturing processes of high quality recycled aggregates were suggested such as heating. In this paper, for the purpose of manufacture of high quality recycled aggregates, the heating processes was considered to the existing process of recycled aggregates. To find the optimum process, the experiment was performed through the statistical design of experiment. The heating temperatures of 4 levels (300, 450, 600 and $750^{\circ}C$) and heating duration time (5, 20, 40, 60minute) were main experimental variables. Through the test results, it was found that the optimum manufacturing condition of coarse recycled aggregate was evaluated to be $600^{\circ}C$ and 40minute.

  • PDF

Insulation Performance and Heating and Cooling Energy Consumption depending on the Window Reveal Depth in External Wall Insulation (외단열 벽체에서 창호 설치 위치에 따른 단열성능 및 냉난방 에너지 소비량)

  • Rhee, Kyu-Nam;Jung, Gun-Joo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.91-98
    • /
    • 2017
  • In this study, the effect of window installation position in the residential building with the external insulation was numerically investigated in terms of insulation performance and heating/cooling energy consumption. For different window positions, 2-D heat transfer simulation was conducted to deduce the linear thermal transmittance, which was inputted to the dynamic energy simulation in order to analyze heating/cooling energy consumption. Simulation results showed that the linear thermal transmittance ranges from 0.05 W/mK to 0.7 W/mK, and is reduced as the window is installed near the external finish line. Indoor surface temperature and TDR analysis showed that the condensation risk is the lowest when the window is installed at the middle of the insulation and wall structure. It was also found that the window installation near the external finish can reduce the annual heating/cooling energy consumption by 12~16%, compared with the window installation near the interior finish. Although the window installation near the external finish can achieve the lowest heating/cooling energy consumption, it might lead to increased condensation risks unless additional insulation is applied. Thus, it can be concluded that the window should be installed near the insulation-wall structure junction, in consideration of the overall performance including energy consumption, condensation prevention and constructability.

Chemical Stability through CO2 Curing of Cement Paste Exposed to High Temperature (고온 환경에 노출된 시멘트 페이스트의 DCG 양생을 통한 화학적 안정화)

  • Kim, Min-Hyouck;Cho, Hyeon-Seo;Lee, Gun-Cheo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.73-74
    • /
    • 2019
  • In order to examine the chemical stabilization through DCG curing of cement paste exposed to high temperature environment, we produced a sample of 40% W/C cement paste and heated it for 180 minutes under the heating temperature of $800^{\circ}C$. The DCG curing time was 6, Three time conditions were divided into 12 and 18 hours. As a result of XRD analysis, Calcite ($CaCO_3$) was found in Theta 29.4, 40, and 46.5o. As the curing time increased, the peak of Calcite also increased, which is due to the increased reaction time with DCG. Therefore, Calcite produced through DCG curing seems to have stabilized chemically by filling the pores generated by heating.

  • PDF

A Study on the 3D Imaging of High Temperature Heating Cement Paste and the Analysis of Variation of the Pore Structure (고온 가열 시멘트 페이스트의 3D 영상화 및 세공구조 변화 분석에 관한 연구)

  • Kim, Min-Hyouck;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.147-148
    • /
    • 2020
  • In case of high temperature damage such as fire, the durability of concrete is reduced due to the collapse of internal pore tissue. Therefore, in this paper, we are going to analyze the pore structure of cement paste hardening agent using MIP analysis and build up 3D data produced using X-ray CT tomography. The test specimen is made of cement paste from W/C 0.4. As the temperature of heating increased, the amount of air gap and the diameter of air gap in cement paste increased. It is judged that the air gap structure inside cement collapsed due to the evaporation of the hydrate, gel count, capillary water, etc. inside the cement due to the high temperature.

  • PDF