• 제목/요약/키워드: Heating experiment

검색결과 868건 처리시간 0.031초

수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구 (An experimental study on the operating performance of facade installed natural circulation type solar thermal system)

  • 백남춘;이왕제;이진국;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구 (A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage)

  • 김지영;백영진;이영수;장기창;나호상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF

HMA의 세포내 산도증가가 온열과 항암화학 치료의 세포독성에 미치는 효과 (Effect of Increased Intracellular pH by HMA on the Cytotoxicity of Combined Treatment of Hyperthermia and Chemotherapy)

  • 허원주;송창원
    • Radiation Oncology Journal
    • /
    • 제13권2호
    • /
    • pp.121-128
    • /
    • 1995
  • Purpose: The enhanced cytotoxic effect of combined treatment of hyper-thermia and chemotherapy by increasing intracellular acidity with HMA was investigated. Materials and Methods: FSall tumor cells were injected on the hindlegs of female $C_3H$ mice. When the tumor volume reached about 200mm3, experiments were performed on the groups classified as follows: Group I :Control, Group II : Melphalan alone (2.5mg/kg, 5mg/kg, 10mg/kg, 15mg/kg), Group III : Heat alone $(42.5^{\cdot}C$ for 1 hour) Group IV : Melphalan + Heat $(42.5^{\cdot}C$ for 1 hour), Group V : HMA(10mg/kg) + Melphalan(5.0mg/kg) + Heat$(42.5^{\cdot}C$ for 1hour). Each group included 8-12 mice on each experiment HMA (3-amino-6-chloro-5-(1-homopiperidyl )-N-(diaminomethylene) -c-pyrazinecarboxamide), an analog of amiloride which increases intracellular pH(pHi) was dissolved in dimethyl sulfoxide (DMS) and injected into the tumor-bearing mice through the tail vein. 10mg/kg of HMA and each dose of melphalan were injected into peritoneum of the tumor-bearing mice 30 minutes before heating. Tumor growth delay was calculated when the tumor volme reached at $1500mm^3$ Excision assay was performed on each group and repeated 2-4 times. Results : Tumor growth delay of each experimental groups at $1500mm^3$ were 9, 10, 13 and 19 days respectively. In vivo-in vitro excision assay using FSall tumor cells, the cytotoxicity of each experimental groups was $1.2{\times}10^7,\;1{\times}10^7,\;6{\times}10^6,\;1.7{\times}10^6\;and\;1{\times}10^5$ clonogenic cells/gm respectively When HMA was added to the combined treatment of heat and .chemotherapy, the tumor growth was delayed more than combined treatment without HMA i.e., 6 days tumor growth delay at $1500mm^3$ of tumor volume. Conclusion: The combined effect of cytotoxicity by heat and chemotherapy can be much more enhanced by HMA.

  • PDF

Doherty 증폭기의 열 메모리 효과 모델링과 보상 (Thermal Memory Effect Modeling and Compensation in Doherty Amplifier)

  • 이석희;이상호;방성일
    • 대한전자공학회논문지TC
    • /
    • 제42권9호
    • /
    • pp.49-56
    • /
    • 2005
  • RF 전력증폭기 및 Doherty 전력증폭기의 열 메모리 효과는 변조신호의 대역폭과 동작 전력의 레벨에 따라 민감하게 영향을 미친다. 본 논문에서는 전기적인 비선형성을 정확히 모델링하고 열 메모리 효과가 Doherty 증폭기의 왜곡형성에 어떤 영향을 미치는지에 대해 연구하였다. Doherty 증폭기의 열 메모리 특성을 모델링하기 위하여 순시적으로 소모되는 전력과 순시 접합온도의 정확한 관계식을 정립하여 제안하였다. 제안된 모델의 파라미터는 서로 다른 여기상태에 따라 전력증폭기의 특성이 결정되는데, 트랜지스터의 열 메모리 효과는 대역폭이 넓은 W-CDMA 및 UMTS 시스템에서 충분히 고려되어야 한다. 이러한 열 메모리 효과를 사전왜곡 함수에 적응하여 선형화된 전력증폭기의 출력스펙트럼에서 최대 20 dB정도의 ACLR 개선효과를 보인다. 측정결과는 60W급 LDMOS Doherty 전력증폭기로 측정하였으며, 열 메모리 보상기는 ADS로 검증하였다.

TOWARD A NEXT GENERATION SOLAR CORONAGRAPH: DEVELOPMENT OF A COMPACT DIAGNOSTIC CORONAGRAPH FOR THE ISS

  • Cho, K.S.;Bong, S.C.;Choi, S.;Yang, H.;Kim, J.;Baek, J.H.;Park, J.;Lim, E.K.;Kim, R.S.;Kim, S.;Kim, Y.H.;Park, Y.D.;Clarke, S.W.;Davila, J.M.;Gopalswamy, N.;Nakariakov, V.M.;Li, B.;Pinto, R.F.
    • 천문학회지
    • /
    • 제50권5호
    • /
    • pp.139-149
    • /
    • 2017
  • The Korea Astronomy and Space Science Institute plans to develop a coronagraph in collaboration with National Aeronautics and Space Administration (NASA) and to install it on the International Space Station (ISS). The coronagraph is an externally occulted one-stage coronagraph with a field of view from 3 to 15 solar radii. The observation wavelength is approximately 400 nm, where strong Fraunhofer absorption lines from the photosphere experience thermal broadening and Doppler shift through scattering by coronal electrons. Photometric filter observations around this band enable the estimation of 2D electron temperature and electron velocity distribution in the corona. Together with a high time cadence (<12 min) of corona images used to determine the geometric and kinematic parameters of coronal mass ejections, the coronagraph will yield the spatial distribution of electron density by measuring the polarized brightness. For the purpose of technical demonstration, we intend to observe the total solar eclipse in August 2017 with the filter system and to perform a stratospheric balloon experiment in 2019 with the engineering model of the coronagraph. The coronagraph is planned to be installed on the ISS in 2021 for addressing a number of questions (e.g., coronal heating and solar wind acceleration) that are both fundamental and practically important in the physics of the solar corona and of the heliosphere.

Analysis on the Formation of Li4SiO4 and Li2SiO3 through First Principle Calculations and Comparing with Experimental Data Related to Lithium Battery

  • Doh, Chil-Hoon;Veluchamy, Angathevar;Oh, Min-Wook;Han, Byung-Chan
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권3호
    • /
    • pp.146-151
    • /
    • 2011
  • The formation of Li-Si-O phases, $Li_4SiO_4$ and $Li_2SiO_3$ from the starting materials SiO and $Li_2O$ are analyzed using Vienna Ab-initio Simulation (VASP) package and the total energies of Li-Si-O compounds are evaluated using Projector Augmented Wave (PAW) method and correlated the structural characteristics of the binary system SiO-$Li_2O$ with experimental data from electrochemical method. Despite $Li_2SiO_3$ becomes stable phase by virtue of lowest formation energy calculated through VASP, the experimental method shows presence of $Li_4SiO_4$ as the only product formed when SiO and $Li_2O$ reacts during slow heating to reach $550^{\circ}C$ and found no evidence for the formation of $Li_2SiO_3$. Also, higher density of $Li_4SiO_4$(2.42 g $ml^{-1}$) compared to the compositional mixture $1SiO_2-2Li_2O$ (2.226 g $ml^{-1}$) and better cycle capacity observed through experiment proves that $Li_4SiO_4$ as the most stable anode supported by better cycleabilityfor lithium ion battery remains as paradox from the point of view of VASP calculations.

콘크리트 수화발열 및 자기수축 특성의 정량적 분석을 위한 통계적 방법 (The statistical method for quantitative analysis of hydration heat and autogenous shrinkage of concrete)

  • 이의배;이형준;구경모;나철성;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.645-648
    • /
    • 2008
  • 본 연구에서는 초기재령 고강도 콘크리트의 수화발열 특성 및 자기수축 특성의 직접적인 상관관계를 분석하기 위한 기초연구로서, 우선 초기재령 콘크리트의 수화온도와 자기수축의 발현 특성을 정량적으로 표현할 수 있는 통계적 방법에 대해 고찰하였다. 우선 수화발열 특성 및 자기수축 특성을 표현할 수 있는 정량적인 계수로서 수화온도와 자기수축이 급격하게 증가하는 구간의 기울기인 수화발열상승속도와 자기수축증가속도를 설정하였으며, 이 두 계수는 통계적 수법을 활용하여 일정범위의 결정계수를 갖는 회귀계수로 산정하는 것으로 제안하였다. 또한 설정된 통계적 분석방법의 유효성을 검증하기 위해 실제 측정된 수화온도 및 자기수축 데이터를 분석하였으며, 그 결과 초기재령 고강도 콘크리트의 수화발열 특성 및 자기수축 특성을 보다 정량적으로 분석할 수 있었으며, 두 가지 특성의 상관관계를 정량적인 수치로 비교 분석하는 것이 가능하였다.

  • PDF

스위칭 속도 및 온도 제어를 사용한 고압용 정지형 무효전력 보상장치의 안정화 (Stabilization of High-Voltage Static Var Compensator Using Switching Velocity and Temperature Control)

  • 김용태;이창석
    • 한국지능시스템학회논문지
    • /
    • 제23권2호
    • /
    • pp.107-112
    • /
    • 2013
  • 본 논문에서는 고압용 정지형 무효전력 보상장치의 스위칭 모듈의 속도 제어 및 온도 제어 기법을 제안한다. 지속적인 전력 수요의 증가에 따른 발전 설비 및 송 배전설비의 신규 건설이 요구되고 있으며, 전력수송설비의 신 증설로 전력수송로의 병목현상에 따른 문제점이 나타나고 있다. 따라서 기존설비의 이용률을 극대화하고, 신규건설 없이 송전용량을 증대시키는 방안이 연구 되고 있다. 기존의 정지형 무효전력 보상장치 제어 방식에서는 전원입력회로에서 전위 검출하여 SCR를 직접 스위칭 동작하게 되어 있어서 노이즈가 발생하게 된다. 제안한 방법은 SCR 양단의 전위차를 바탕으로 스위칭 제어하여 스위칭 속도가 향상되고 노이즈가 감소하게 된다. 또한 스위칭 속도 증가로 발생하는 발열을 실시간 온도 제어함으로 안정성을 향상하였다. 실제 실험 환경을 구성하여 제안한 고압용 정지형 무효전력 보상장치의 속도 및 온도 제어를 실험하고, 실제 현장에서 성능을 검증하였다. 제안한 고압용 정지형 무효전력 보상장치의 스위칭 모듈을 통한 온도 제어를 실험하고, 실제 현장에서 성능을 검증하였다.

300MW급 Shell형 1단 분류층 가스화기 성능에 대한 전산수치해석 : 석탄·바이오매스 혼합비에 따른 CO2 가스화 반응 (Numerical Study on 300 MW Shell-Type One-Stage Entrained Flow Bed Gasifier : Effect of Coal·Biomass Blending Ratio on CO2 Gasification)

  • 홍정우;박상신;송지훈;황정호
    • 한국수소및신에너지학회논문집
    • /
    • 제23권3호
    • /
    • pp.274-284
    • /
    • 2012
  • Recently, gasification technology for coal blended with biomass has been an issue. Especially, An advantages of coal blended with biomass are 1) obtaining high cold gas efficiency, 2) obtaining syn-gas of high-high heating value (HHV), and 3) controlling occurrence of $CO_2$. In this study, the efficiency and characteristic of 300 MW Shell type gasifier were predicted using CFD simulation. The CFD simulation was performed for biomass coal blending ratios of 0~0.2, 0.5, 1 and $O_2$/fuel ratios of 0.5~0.84. Kinetic parameters (A, $E_a$) obtained by $CO_2$ gasification experiment were used as inputs for the simulation. In results of CFD simulation, residence times of particle in 300MW Shell type gasifer presented as 7.39 sec ~ 13.65 sec. Temperature of exit increased with $O_2$/fuel ratio as 1400 K ~ 2800 K, while there is not an effects of biomass coal blending ratios. Considering both aspects of temperature for causing wall slagging and high cold gas efficiency, the optimal $O_2$/fuel ratio and blending ratio were found to be 0.585 and 0.05, respectively.

물-공기 지열 멀티형 열펌프 시스템 실증연구 (Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System)

  • 김철우;김병국;이평강;임효재;강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.