• 제목/요약/키워드: Heating Rate

검색결과 1,912건 처리시간 0.032초

Water film covering characteristic on horizontal fuel rod under impinging cooling condition

  • Penghui Zhang;Bowei Wang;Ronghua Chen;G.H. Su;Wenxi Tian;Suizheng Qiu
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4329-4337
    • /
    • 2022
  • Jet impinging device is designed for decay heat removal on horizontal fuel rods in a low temperature heating reactor. An experimental system with a fuel rod simulator is established and experiments are performed to evaluate water film covering capacity, within 0.0287-0.0444 kg/ms mass flow rate, 0-164.1 kW/m2 heating flux and 13.8-91.4℃ feeding water temperature. An effective method to obtain the film coverage rate by infrared equipment is proposed. Water film flowing patterns are recoded and the film coverage rates at different circumference angles are measured. It is found the film coverage rate decreases with heating flux during single-phase convection, while increases after onset of nucleate boiling. Besides, film coverage rate is found affected by Marangoni effect and film accelerating effect, and surface wetting is significantly facilitated by bubble behavior. Based on the observed phenomenon and physical mechanism, dry-out depth and initial dry-out rate are proposed to evaluate film covering potential on a heating surface. A model to predict film coverage rate is proposed based on the data. The findings would have reliable guide and important implications for further evaluation and design of decay heat removal system of new reactors, and could be helpful for passive containment cooling research.

저온 소결용 PMN-PT-BT 세라믹스의 물성에 미치는 승온 속도의 영향 (Influence of Heating Rate on the Properties of Low-Temperature-Sinterable PMN-PT-BT Ceramics)

  • 임경란;김창삼
    • 한국세라믹학회지
    • /
    • 제42권1호
    • /
    • pp.33-36
    • /
    • 2005
  • 저온 소결용 PMN-PT-BT분말을 $850^{circ}C/2h$ 소결할 때 승온 속도를 분당 5, 10, $20^{circ}C$로 변화하며 물성에 미치는 영향을 조사하였다. PbO(응점 $886^{circ}C$)의 휘발이 미미한 소결온도에서는 분당 $5^{circ}C$로 승은하여 소결한 것이 승온 속도 $10^{circ}C$$20^{circ}C$의 경우에 비하여 보다 균일한 미세구조를 나타내며, 소결밀도 $7.93g/cm^{3}$, 실온 유전을 15300, 유전손실 $0.92\%의 우수한 유전 특성을 나타내었다.

Control of Connectivity of Ni Electrode with Heating Rates During Sintering and Electrical Properties in BaTiO3 Based Multilayer Ceramic Capacitors

  • Yoon, J.R.;Shin, D.S.;Jeong, D.Y.;Lee, H.Y.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권4호
    • /
    • pp.181-184
    • /
    • 2012
  • $BaTiO_3$ based multilayer ceramic capacitors with Ni electrodes can be explained as 2-2 composites with different thermal expansion coefficient and sintering behaviors. To achieve the high capacitance and reliability of MLCCs, a homogenous Ni electrode configuration with high connectivity is required. We controlled the heating rates during sintering to achieve densification by suppressing grain growth. Experimental results revealed that a large heating rate gave high connectivity of Ni electrode, high capacitance, small dissipation factor, high breakdown voltage, and high reliability of MLCC chips.

800℃ 조건에서의 시멘트 경화체의 균열 특성 (Cracking Behavior of Cement and Concrete Damaged by High Temperature of 800℃)

  • 지우람;박지웅;신기돈;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.26-27
    • /
    • 2017
  • In this study, the cracking characteristics of cured pastes at 800℃ were investigated by X-ray CT. The test specimens were fabricated with and without aggregate, and the heating rate condition was applied at rapid heating (10.0℃/min). It is considered that the rapid heating condition does not cause a temperature gradient phenomenon because the temperature difference between the surface and the center of the sample is small due to a low heating rate unlike an actual fire. The cracking condition of the specimens without aggregate was more severe than that of specimens with aggregate.

  • PDF

자기공명영상시스템에서의 의료용 리드선의 전자기적 호환 연구 (Electromagnetic Compatibility Study of a Medical Lead for MRI Systems)

  • 유형석
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2019-2022
    • /
    • 2016
  • In the presence of an electrically conducting medical lead, radio frequency (RF) coils in magnetic resonance imaging (MRI) systems may concentrate the RF energy and cause tissue heating near the lead. A novel design for a medical lead to reduce this heating by introducing pins in the lead is presented. Peak 10 g specific absorption rate (SAR) in heart tissue, an indicator of heating, was calculated and compared for both conventional (Medtronic) lead design and our proposed design. Remcom XFdtd software was used to calculate the peak SAR distribution in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T), 128 MHz (3 T) and 300 MHz (7 T) using a model of an MR birdcage body coil. The proposed design of adding pins to the medical lead can significantly reduce the heating from different MRI systems.

Joule-heating induced crystallization (JIC) of amorphous silicon films

  • Hong, Won-Eui;Lee, Joo-Yeol;Kim, Bo-Kyung;Ro, Jae-Sang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.459-462
    • /
    • 2007
  • An electric field was applied to a conductive layer to induce Joule heating in order to carry out the crystallization of amorphous silicon. Polycrystalline silicon was produced through a solid state transformation within the range of a millisecond. Uniformly distributed grains were obtained due to enormously high heating rate.

  • PDF

급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구 (Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger)

  • 정동화;김주완;백영진;이영수;정대헌
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구 (A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick)

  • 김용기;이태원
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.183-189
    • /
    • 2012
  • Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.

소결과정에 있어서 Bindex Burnout 온도 및 소결온도까지의 가열속도가 MLC의 전기적 특성에 미치는 영향 (The Effect of Binder Burnout Time and Heating Rate on the Electrical Properties of Multilayer Ceramic Capacitors)

  • 김호기;오창섭;김용혁
    • 한국세라믹학회지
    • /
    • 제24권3호
    • /
    • pp.207-214
    • /
    • 1987
  • This paper is to determine the effect of binder burnout time and heating rate on the electrical propertries of type II multilayer ceramic capacitors(MLC). The quality of multilayer ceramic capacitor depends suitable on the binder burnout time, which is determined for at least 24 hours in the PVB-binder system. It is suggested that theelectrical properties of multilayer ceramic capacitor is due to the control of heating rate, with the dipole moment density from grain size distributiion. Comparing the fast firing with slow, we observed a small but consistent improvement in the electrical properties.

  • PDF

90kW급 우드칩 온수 보일러 특성 및 성능 시험 (Measurement of Efficiency and Flue Gas Concentration of 90 kW Woodchip Boiler)

  • 강새별;김종진;최규성;이웅진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.194-197
    • /
    • 2008
  • We measured the efficiency and flue gas concentration of a 90kW woodchip boiler which is for heating water of lodging. At nominal operating condition, the fuel, woodchip is fed into the boiler at a rate of 22.6 kg/h. In order to determine the efficiency of the boiler, we measured the water flow rate, woodchip flow rate, heating value and water content of woodchip, temperature of inlet and outlet of heating water. The results of test show that the power output of the woodchip boiler is 90.0 kW(77,400 kcal/h) and the thermal efficiency of the boiler is 88.5%. By using a gas analyser, flue gas concentrations are measured. The results show that O2 in the flue gas is 10.2%, CO concentration is 393 ppm and NOx concentration is 74 ppm.

  • PDF