• Title/Summary/Keyword: Heated Tube

검색결과 192건 처리시간 0.021초

열처리조건에 따른 Bi-2212 라운드형 선재의 특성 (Characteristics of Bi2212 Round-wire Depending on Heat Treatment Condition)

  • 이남일;장건익;오상수;하동우;김상철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.1-4
    • /
    • 2006
  • The characteristics of Bi2212 round wire was systematically studied depending on different heat treatment conditions. Initial wire was drawn after routine PIT (Powder In Tube) process. The wire was divided into 3 pieces with 10 cm in length and 2.5 mm in diameter. 3 wires were pre-heat treated separately by different heat treatment schedules, heated in air and nitrogen atmosphere and centrifugally melted. Pre-heated wires were annealed at $845^{\circ}C$ for 40 hours in oxygen atmosphere. SEM results indicate that all pre-heated wires showed highly oriented microstructure. However the wire by centrifugally melted process showed higher density and better electric properties as compared with 2 other wires pre-heated in air and nitrogen atmosphere. The critical current of a centrifugally melted wire was about 18 A in 77 K.

Air Bulging을 이용한 열간 알루미늄 성형에 관한 연구 (Study on Al Hot Forming using Air Bulging)

  • 박동환;강성수;김병년
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.145-147
    • /
    • 2009
  • The benefits of hydroforming technology are known as weight and cost savings through part consolidation and reduced post-forming processes such as welding and piercing. Hydroforming technology has some weaknesses in terms of process cycle times. But, as the hydraulic system and process designs are continuously developed, the cycle time is also reduced to acceptable and competitive levels. Hot air bulging is one of recently developed hydroforming techniques. Hot air bulging in order to further extend the forming degrees of Al lightweight material is investigated. A heated tube is placed in a heated die and sealed at the ends by sealing cylinders. The tube is subsequently expanded against the die cavity wall by internal pressure provided by air medium. The result of this study shows that axial feeding speed and air pressure have an effect on formability of Al air bulging at elevated temperature.

  • PDF

형상이 다른 수평 원형 전열관의 응축 성능에 관한 연구 (A Study on the Condensation Performance for the Horizontal Heat Transfer Tubes with Various Fin Attached)

  • 한규일;박종운
    • 수산해양교육연구
    • /
    • 제4권1호
    • /
    • pp.47-61
    • /
    • 1992
  • An experimental study was carried out to investigate the condensation performance for the horizontal cylindrical heat transfer tube with various fin attached using R-11 vapor. The heat transfer tube used in this study was supplied by SUNG HYUNG METAL CO., LTD. Four different types of heat transfer tubes (plain tube, SH-CYR tube, thermocor tube and thermoexcel tube) were used. Each tube was surrounded by circular acrylate tube, and R-11 gas heated by boiler flows into the acrylate tube. Cooling water counter-flows in heat transfer tubes. Heat transfer coefficient of the plain tube from measured data was compared with those of three other tubes. The results are summarized as follows: 1. As the cooling water temperature decreased, the liquid film of R-11 turned to droplet drop on the top surface of the horizontal tube. 2. Heat transfer coefficient calculated theoretically was higher than that obtained from the experimental data. 3. As far as the condensation concerns the thermocor tube is the highest, the SH-CYR tube is the second, and the thermoexcel tube is the third excluding the plain tube.

  • PDF

Effects of Pool Subcooling on Boiling Heat Transfer in an Annulus

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.460-474
    • /
    • 2004
  • Effects of liquid subcooling on pool boiling heat transfer in an annulus with an open bottom have been investigated experimentally. A tube of 19.1mm diameter and the water at atmospheric pressure have been used for the fest. Up to $50^{\circ}C$ of liquid subcooling has been tested and experimental data of the annulus have been compared with the data of a single unrestricted tube. Temperatures on the heated tube surface fluctuate only slightly regardless of the heat flux in the annulus, whereas high variation is observed on the surface of the single tube. An increase in the degree of subcooling decreases heat transfer coefficients greatly both for the single tube and the annulus. Heat transfer coefficients increase suddenly at ${\Delta}T_{sub}\;{\le}\;10^{\circ}C$ and much greater change in heat transfer coefficients is observed at the annulus. To obtain effects of subcooling on heat transfer quantitatively, two new empirical equations have been suggested, and the correlations predict the empirical data within ${\pm}30\%$ error bound excluding some data at lower heat transfer coefficients.

가열된 튜브에서 발생하는 강제 대류열전달 특성에 관한 실험적 연구 (Experimental Investigation on Forced Convective Heat Transfer Characteristic Generated to Heated Tube)

  • 박희호;이양석;김선진
    • 한국추진공학회지
    • /
    • 제10권3호
    • /
    • pp.90-98
    • /
    • 2006
  • 재생냉각 시스템의 냉각제로 사용하는 탄화수소계열 연료인 Jet A-1의 냉각특성과 강제대류 열전달 특성을 파악하기 위해 가열된 직선 튜브를 제작하였다. 냉각제의 입, 출구온도와 튜브의 외벽 온도를 측정하여 강제대류 열전달 특성을 고찰하였다. 결과를 통하여 Jet A-1을 사용한 경우에는 일정 유동조건에 대하여 burnout이 발생하는 최초의 벽 온도를 결정함으로써 냉각제가 수용할 수 있는 최대 열유속을 확인하였다. 냉각제의 유속과 입구온도가 대류열전달 특성에 직접적인 영향을 주는 인자임을 확인하였다.

등축 유로를 가진 이중진공관형 태양열 집열기의 열성능에 관한 시뮬레이션 연구 (The Performance Simulation of All-Glass Vacuum Tubes with Coaxial Fluid Conduit)

  • 이상진;현명택;박윤철;천원기;이정호
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.27-38
    • /
    • 2004
  • A numerical investigation has been carried out for a solar system, which consists of all glass solar vacuum tubes Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is filled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing all-glass solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show good agreement when compared with other experimental data demonstrating the reliability of the present model.

등축 유로 장착 이중 태양열 진공관의 열적 특성에 관한 수치해석적 연구 (A Numerical Study on the Thermal Characteristics of Double Skin Vacuum Tubes with Coaxial Fluid Conduit)

  • 현준호;박윤철;천원기;이상진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.567-570
    • /
    • 2006
  • A numerical study has been carried out for a solar water heater which consists of double skin solar vacuum tubes. Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is tilled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing double skin solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show a good agreement when compared with other experimental data demonstrating the reliability of the one-dimensional model employed.

  • PDF

R22 대체 냉매의 마이크로 핀관내 흐름 비등 열전달 특성 (Flow Boiling Heat Transfer Characteristics of R22 Alternative Refrigerants in a Horizontal Microfin Tube)

  • 한재웅;김신종;정동수;김영일
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.692-700
    • /
    • 2001
  • Flow boiling heat transfer coefficients(HTCs) of R22, R134a, R407C, and R410A were measured experimentally for a horizontal plain and a microfin tube. Experimental apparatus was composed of 3 main parts: a refrigerant loop, a water loop and a water-glycol loop. The test section in th refrigerant loop was made of a copper tube of 9.52 mm outer diameter and 1 m length for both tubes. The refrigerant was heated by passing hot water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of $5^{\circ}C$ with mass fluxes of 100~300 kg/$m^2$s. Test results showed that at similar mass flux the flow boiling HTCs of R134a were similar to those of R22 for both plain and microfin tube. HTCs of R407C were similar to those of R22 for a plain tube but lower than those of R2 by 25~48% for a microfin tube. And HTCs of R410A were higher than those of R2 by 20~63% for a plain tube and were similar to those of R22 for a microfin tube. In general, HTCs of a microfin tube were 1.8~5.7 times higher than those of a plain tube.

  • PDF

CMP 방법으로 제조한 BSCCO 2212 튜브의 임계전류특성에 미치는 열처리 온도의 영향 (Effects of Heat-treatment Temperature on the Critical Current of BSCCO 2212 Tube Prepared by CMP Method)

  • 최정숙;오성룡;전병혁;김형섭;김혜림;현옥배;김찬중
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.98-103
    • /
    • 2006
  • [$Bi_2Sr_2Ca_1Cu_2O_x$](BSCCO 2212) tubes were fabricated by centrifugal melting process(CMP). BSCCO 2212 powder was melted in a Pt crucible and solidified in a rotating steel mold. The BSCCO 2212 tube samples separated from steel mold were heat-treated at $800^{\circ}C\;and\;810^{\circ}C$ in oxygen flow. The critical current($I_c$) of the samples was measured by transport measurement at 77K, and the microstructure was investigated by scanning electron microscope. The $J_c$ at 77K of the tubes heated treated at $800^{\circ}C\;and\;810^{\circ}C$ were 197 and 240 $A/cm^2$, respectively. It was observed that the plate like grains in BSCCO 2212 tube was more developed in the sample heat treated at $810^{\circ}C\;and\;800^{\circ}C$ heated tube. It is found that the critical current($I_c$) of the BSCCO 2212 sample was dependent on the heating schedule regarding the growth of the BSCCO 2212 grains.

  • PDF

평행류형 마이크로채널 이산화탄소 증발기에서 냉매분배에 관한 연구 (A Study on the Refrigerant Distribution in a Parallel Flow Micro-Channel $CO_2$ Evaporator)

  • 정시영;김대환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1079-1083
    • /
    • 2009
  • In this study, the distribution of $CO_2$ in an evaporator with 10 parallel micro channel aluminum tubes are experimentally investigated. Each tube has 6 circular micro channels with a diameter of 0.8mm. The tubes are heated with electric resistance wires, and the distribution of $CO_2$ into each tube is investigated by measuring the outer wall temperature. The outer wall temperature was found to be higher at the exit part of the top tube. It is thought that the $CO_2$ vapor at the upper part of the header reduces the mass flow rate of $CO_2$ into the top tube.

  • PDF