유전 알고리즘을 활용한 전기 자동차 배터리 방열성능 향상을 위한 가이드 베인 최적설계 (Optimal Design of Guide Vane for Improvement of Heat Removal Performance of Electric Vehicles Battery Using Genetic Algorithm)

  • 송지훈;김윤제
    • 자동차안전학회지
    • /
    • 제14권1호
    • /
    • pp.55-61
    • /
    • 2022
  • Along with global environmental issues, the size of the electric vehicle market has recently skyrocketed. Various efforts have been made to extend mileage, one of the biggest problems of the electric vehicles, and development of batteries with high energy densities has led to exponential growth in mileage and performance. However, proper thermal management is essential because these high-performance batteries are affected by continuous heat generation and can cause fires due to thermal runaway phenomena. Therefore, thermal management of the battery is studied through the optimal design of the guide vanes, while utilizing the existing battery casing to ensure the safety of the electric vehicles. A battery from T-company, one of a manufacturer of the electric vehicles, was used for the research, and the commercial CFD software, ANSYS CFX V20.2, was used for analysis. The guide vanes were derived through optimal design based on a genetic algorithm with flow analysis. The optimized guide vanes show improved heat removal performance.

Urban Thermo-profiles and Community Structure of Quercus mongolica Forests along an Urban-rural Land Use Gradient: Implications for Management and Restoration of Urban Ecosystems

  • Cho, Yong-Chan;Cho, Hyun-Je;Lee, Chang-Seok
    • Journal of Ecology and Environment
    • /
    • 제32권3호
    • /
    • pp.167-176
    • /
    • 2009
  • Land cover changes associated with urbanization have driven climate change and pollution, which alter properties of ecosystems at local, regional, and continental scales. Thus, the relationships among urban ecological variables such as community composition, structure, health, soil and functioning need to be better understood to restore and improve urban ecosystems. In this study, we discuss urban ecosystem management and research from a futuristic perspective based on analyses of vegetation structure, composition, and successional trends, as well as the chemical properties of soils and the distribution of heat along an urban-rural gradient. Urban thermo-profile analysis using satellite images showed an obvious mitigating effect of vegetation on the Seoul heat island. Community attributes of Quercus mongolica stands reflected the effects of urbanization, such as pronounced increases in disturbance-related and pollution-tolerant species, such as Styrax japonica and Sorbus alnifolia. Retrogressive successional trends were detected in urban sites relative to those in rural sites. Changes in the urban climate and biotic environment have the potential to significantly influence the practice and outcomes of ecological management, restoration and forecasting because of the associated changes in future bio-physical settings. Thus, for management (i.e., creation and restoration) of urban green spaces, forward-thinking perspectives supported by historical information are necessary.

A Study on Development of a Plugging Margin Evaluation Method Taking Into Account the Fouling of Shell-and-Tube Heat Exchangers

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1934-1941
    • /
    • 2006
  • As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.

다관원통형 열교환기의 파울링 현상을 고려한 관막음 여유 평가법 개발 연구 (A Study on the Development of Plugging Margin Evaluation Method Reflected the Fouling of a Shell-and-Tube Heat Exchanger)

  • 황경모;진태은
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1384-1389
    • /
    • 2004
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of domestic nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions as a means of heat exchanger management. Except for the fouling level generated in operation of heat exchangers, also, all of the tubes of heat exchangers have been replaced when the number of plugged tubes exceeds the plugging criteria based on design performance sheet. This paper describes the plugging margin evaluation mettled reflected the fouling of shell-and-tube heat exchangers, which can evaluate the thermal performance for heat exchangers, estimate the future fouling variations, and reflect the current fouling level. To identify the effectiveness of the developed method, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

LSC를 이용한 생활용품의 발열량 특성에 관한 연구 (A Study on the Heat Release Characteristic of Household Items using LSC(Large Scale Cone Calorimeter))

  • 박영주;백창선;이해평;홍이표
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.38-44
    • /
    • 2015
  • For this study, fire tests were performed targeting household items (Sofa, Drawer, Refrigerator, Washing machine) using a large cone calorimeter (Large Scale Cone Calorimeter, LSC). The data were obtained focusing on the fire characteristic of the data when the actual fire occurs. The study results showed the following mean HRR of the household items; drawer 2843 KW, sofa 2939 KW, washing machine 719 KW, refrigerator 2907 KW, and THR is found in sofa 2202 MJ, drawer 1559 MJ, refrigerator 1193 MJ, washing machine 627 MJ. From the result, it could be found that the sofa can cause significant heat generation when the fire occurs, and the flashover tendency was found relatively high in compartment fire. In addition, a weight of the four our household items was reduced sharply in a similar time (20min before and after) degree after ignition. The drawer and sofa which has a high heat release can be considered to speed up the fire spread as their weight decrease rapidly and showed relatively weak to the fire compared to the refrigerator and washing machine.

이산화탄소 에어컨 시스템을 이용한 연료전지 자동차의 스택 냉각성능에 대한 실험적 연구 (Experimental Studies on the Stack Cooling Performance Using a $CO_2$ Air Conditioning System in Fuel Cell Vehicles)

  • 김성철;김민수;원종필
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.87-93
    • /
    • 2008
  • The $CO_2$ air conditioning system installed in fuel cell vehicles could be used either for stack cooling or for cabin cooling, and thus was used for the stack cooling when additional stack heat release was required over a fixed radiator capacity for high power generation. This study investigated the performance of the stack cooling system using $CO_2$ air conditioner at various operating conditions. Also, the heat releasing effectiveness and mutual interference were analyzed for the stack cooling system using an air conditioner and compared with the conventional radiator cooling system with/without cabin cooling. The heat release of the stack cooling system with the aid of $CO_2$ air conditioner increased up to 36% more than that of the conventional radiator cooling system with cabin cooling. Furthermore, the heat release of the stack cooling system using $CO_2$ air conditioner increased more by 7% than that of the conventional radiator cooling system without cabin cooling.

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권3호
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

PC를 이용한 공정관리시스템 개발 (Process Management System using a PC)

  • 송준엽;이승우;이현용
    • 산업공학
    • /
    • 제6권2호
    • /
    • pp.171-181
    • /
    • 1993
  • In this study, a process management system is designed that can automatically control the heat treating atmosphere, and a managment software is developed to monitor and control continously the heat treating process using a n interface device. Especially, a communication protocol is developed to control and monitor atmosphere condition, temperature, surrounding gas, and time. The developed interface device, called COMPORT SELECTOR is to send and receive information from PID controllers and PLC via RS-232C communication. This system will reduce manufacturing cost and cycle time, and improve the effectiveness of working process and quality.

  • PDF

에너지 절약(節約) 방안(方案)과 이용(利用)에너지 (A Study on Energy Conservation and Availability)

  • 함효준
    • 품질경영학회지
    • /
    • 제12권1호
    • /
    • pp.31-34
    • /
    • 1984
  • The industrial sector is the largest energy consumer, accounting for 44% of the total energy consumption of Korea in 1981. Energy conservation in the industrial processes is one of the most important strategies to the energy conservation to the nation. This paper introduces principles of energy conservation which is the maximum thermodynamic efficiency in energy use. Two important factors considered are how much heat is available and how good is the heat available (the quality of energy).

  • PDF