냉각된 복사천장패널의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling)

  • 이태원;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF

마이크로채널 형상에 따른 PCHE 열유동 수치해석 (Numerical Simulation of Thermal Performance of Printed Circuit Heat Exchangers with Microchannels of Different Shapes)

  • 조연화;이규정;문동주;김윤호
    • 대한기계학회논문집B
    • /
    • 제35권1호
    • /
    • pp.61-66
    • /
    • 2011
  • 새롭게 제안된 형상의 마이크로채널 PCHE는 기존의 상용 열교환기에 비해 고성능, 고효율의 특성을 보이며 열교환을 수행한다. 본 연구에서는 I, Wavy, Beehive, Surf, I-Wavy, I-Beehive, I-Surf 의 형상을 갖는 다양한 마이크로채널을 모델링하였다. 질량유속 변화에 따른 다양한 마이크로채널 내 유체의 유동특성, 열전달, 압력강하를 살펴보았고 그 결과는 마이크로채널의 열전달 능력을 향상시키는데 이용된다. I 채널은 새롭게 적용된 채널 형상과의 성능비교를 위해 해석을 수행하였다. 다양한 레이놀즈수 변화 하에서 고온측과 저온측 유체는 대향류 형태로 열교환이 이루어지도록 하였다. 수치해석 결과 Surf 형상이 다른 형상들보다 열교환 성능이 우수함을 확인하였다.

수소액화용 극저온 열교환기 내 촉매 수소 전환반응에 관한 연구 (A Study on the Catalytic Ortho-Para Hydrogen Conversion in the Cryogenic Heat Exchanger Filled with Catalysts for Hydrogen Liquefaction)

  • 손상호;윤석호
    • 한국수소및신에너지학회논문집
    • /
    • 제32권3호
    • /
    • pp.180-188
    • /
    • 2021
  • This paper conducted a study on the ortho-para hydrogen conversion in the cryogenic heat exchanger filled with catalysts for hydrogen liquefaction by utilizing the numerical model of plate-fin heat exchanger considering catalytic reaction of ortho-para hydrogen conversion, heat and mass transfer phenomena and fluid dynamics in a porous medium. Various numerical analyzes were performed to investigate the characteristics of ortho-para hydrogen conversion, the effects of space velocity and activated catalyst performance.

분무 증발을 이용한 칩 냉각 향상에 대한 수치적 연구 (NUMERICAL STUDY OF CHIP COOLING ENHANCEMENT WITH EVAPORATING MIST FLOW)

  • 노상은;김동철;손기헌
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.9-16
    • /
    • 2013
  • The heat transfer enhancement of heat sink with mist flow is studied numerically by solving the conservation equations for mass, momentum and energy in the continuous and dispersed phases. A Lagrangian method is used for tracing dispersed water droplets in the heat sink and an Eulerian species transport model for air and steam mixture. The continuous and dispersed phases are interacted with the drag and evaporation source terms. The computed results show that addition of evaporating mist droplets enhances the cooling performance of heat sink significantly.

혼합냉매의 성분비 조절을 통한 열펌프의 용량조절 (Capacity Modulation of a Heat Pump System by Changing the Composition of Refrigerant Mixtures)

  • 김민성;김민수;김용찬
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.258-266
    • /
    • 2000
  • Experimental investigation and cycle simulation of a capacity modulation of a heat pump system using a hydrofluorocarbon (HFC) refrigerant mixture, R32/134a as an alternative to R22, have been done. In the cycle simulation, the refrigeration system was operated by assigning the temperatures of the external heat transfer fluids with the heat exchangers generalized by an average effective temperature difference. Heating capacity, cooling capacity, and coefficient of performance (COP) of the system were investigated at several operating conditions. Experimental apparatus which had a refrigeration part and a composition changing part was built, and the performance of the heat pump system filled with R32/134a mixture was investigated. A gas-liquid separator was used in the experiment to change the composition by collecting the vapor and the liquid Phase separately, The mass fraction of the charged refrigerant in the heat pump system was 40/60 and 70/30 by weight percentage. The composition of the refrigerant with initial composition of 40/60 varied from 29/71 to 41/59 in the refrigeration cycle. For the refrigerant with initial composition of 70/30, the composition varied from 65/35 to 75/25.

  • PDF

보텍스튜브 성능향상을 위한 유입노즐 조건에 관한 연구 (Inflow Nozzle Conditions for Improving Vortex Tube Performance)

  • 최훈기;유근종;임윤승
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.68-76
    • /
    • 2018
  • A vortex tube is a simple energy separating device that splits a compressed air stream into a cold and hot stream without any external energy supply or chemical reactions. The efforts of many researchers and designers have been focused on improvement of vortex tube efficiency by changing the parameters affecting vortex tube operation. The effective parameters are nozzle specifications and inflow pressure conditions. Effects of different nozzle cross-sectional area and number of nozzles are evaluated by computational fluid dynamics (CFD) analysis. In this study, CFD analysis of 3-D steady state and turbulent flow through a vortex tube was performed. We investigated the cold air mass flow rate, the cold air temperature, and the cold air heat transfer rate behavior of a vortex tube by utilizing seven straight nozzles and four inflow pressure conditions.

수평 냉각관 외부를 흘러내리는 $LiBr-H_2O$ 수용액의 유동 및 열/물질 전달 특성에 관한 실험적 연구 (An Experimental Study on Flow and Heat / Mass Transfer Characteristics of $LiBr-H_2O$ Solution Flowing over a Cooled Horizontal Tube)

  • 설신수;이상용
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1085-1096
    • /
    • 2000
  • An experimental study was performed to examine the heat and mass transfer characteristics of $LiBr-H_2O$ solution flowing over a single horizontal tube with the water vapor absorption. Effects of the flow rate and the temperature of the solution at the top of the tube, the absorber pressure and the drainage pattern were considered. The absorption rate depends highly on the absorber pressure at the low flow rate condition while on the solution inlet temperature at the high flow rate condition. Also, when the flow rate is low, the absorption performance with the sheet flow drainage appeared to be higher than that with the dripping/jet drainage. However, at the high flow rate condition, the case became reversed. The liquid film became wavy with the higher absorption rate. The waves were more probable to form with the lower flow rate and temperature of the solution, and with the higher absorber pressure.

정익 후연의 냉각유체분사를 포함한 축류터빈단의 성능해석 (Performance Analysis of an Axial Flow Turbine Stage with Coolant Ejection from Stator Trailing Edge)

  • 김동섭;김재환;노승탁
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.831-840
    • /
    • 1999
  • In this work, an aerothermodynamic calculation model for cooled axial flow turbine blades with trailing edge ejection is suggested and a mean line performance analysis of a turbine stage with nozzle cooling is carried out. A unique model regarding the interaction between coolant and main gas is proposed, while existing correlations are adopted to predict viscous loss and blade outflow angle. The interactions considered are the heat transfer from main gas to coolant and the temperature and pressure losses by the mixing of two streams due to the trailing edge coolant ejection. For a stator blade without ejection, trailing edge loss calculated by the trailing edge analysis is compared with that calculated by loss correlation. The effect of heat transfer effectiveness of coolant passage on the mixing loss is analyzed. For a model turbine stage with nozzle cooling, parametric analyses are carried out to investigate the effect of main design variables(coolant mass flow ratio, temperature and ejection area) on the stage performance.

전산 유체 모델링을 이용한 평판형 고체산화물 연료전지 작동특성 전산모사 (Performance Simulation of Planar Solid Oxide Fuel Cells Characteristics: Computational Fluid Dynamics)

  • 우효상;정용재
    • 전기화학회지
    • /
    • 제7권2호
    • /
    • pp.69-79
    • /
    • 2004
  • 전산모사를 이용하여 특성을 정확하게 모사하기 위해서는 전지 내부에서 발생하는 다양한 물리적, 화학적 현상을 고려하여야 한다. 이를 위해, 본 연구에서는 다양한 전지 내부 현상에 대한 변수를 고려할 수 있는 전산유체 상용코드인 CFD-ACE+를 이용하여 평판형 고체산화물 연료전지의 작동 특성을 분석하였다. 단위 스택에서 발생하는 물질전달과 열전달 및 전기화학 반응에 의한 전하이동을 복합적으로 고려하여, 작동조건 하에서 각 공정적, 구조적 변수 변화에 따른 전지특성을 예측하였다. 이러한 전산모사 방법을 통하여 확산과 유동에 의한 전지 내 반응물과 생성물의 mass fraction 분포와 단위 스택의 내부 온도분포 그리고 전지 특성을 나타내는 polarization curve에 의한 고체산화물 연료 전지의 분극 특성을 정성, 정량적으로 제시하였다. 본 연구를 통해 평판형 단위 스택 내에서의 다양한 변수 변화에 따른 전지의 작동 특성에 대한 효율적 예측이 가능하였고, 고체산화물 연료전지 작동 시 발생하는 현상에 대한 전산모사 접근법을 체계적으로 제시할 수 있었다.

저온 수직평판에서 착상에 대한 운전조건의 영향 (The Effect of Operating Conditions on the Frost Formation in a Vertical Plate at a Low Temperature)

  • 이관수;이태희;김우승
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3305-3314
    • /
    • 1994
  • In this study, the influence of a frost formed on the vertical plate for different operating conditions(the temperature of the air, the humidity of the air, the velocity of the air, and the temperature of the cooling plate) is investigated. The performance of the heat exchanger is examined by introducing a parameter such as the energy transfer resistance. Correlations which relate frost density, frost thickness and energy transfer resistance to Reynolds number, air temperature and humidity, and cooling plate temperature are developed. Static pressure drop and air flow rate are expressed as a function of free flow area of air.