• 제목/요약/키워드: Heat absorption rate

검색결과 247건 처리시간 0.026초

도시의 방사전열에 관한 기초 연구 (A Basic Study on Urban Radiation Heat Transfer)

  • 김종민
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.35-43
    • /
    • 2002
  • This research makes that quantitative radiation property of an actual town ward is obtained in quest of the parameter with regard to a radiation heat transfer property and set up several town ward models that reproduced a solid form of a city along the attribute of the city. A regular trend possibility that is able to evaluate a radiation characteristics of a town ward quantitatively from a town ward guideline and confirmation that is produced about each parameter as a result of a numerical value simulation it obtained. This research shot a coefficient of Gebhart's emission absorption. sky radiation absorption rate direct solar radiation absorption rate the parameter with regard to a radiation heat transfer characteristics of a town ward in each town ward model and a volume rate of a town ward advances case study under regular such condition and shot the absorption rate, direct and others days and calculated an absorption rate and checked about the relation between a town ward and each radiation heat transfer property of a city.

수직 액막형 흡수기의 흡수성능 변화에 미치는 냉각수 유량의 영향 (Effect of the Flow Rate of Coolant on the Absorption Peformance of a Vertical Absorber)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.410-417
    • /
    • 2006
  • The present study predicted the effect of the flow rate of coolant on the absorption performance of a vertical falling film type absorber Heat and mass transfer peformances were numerically investigated. The exit temperatures of solution and coolant were decreased as the flow rate of the coolant was increased at the film Reynolds number of 100. The absorption mass flux was increased and then decreased as the distance from the inlet of the absorber was increased. The distance showing the maximum absorption mass flux was ranged from 0.3 to 0.5m. The heat flux and the absorption mass flux were increased and then slowly decreased as the flow rate of the coolant was increased. The maximum values were obtained at the flow rate of coolant of 2.0L/min.

흡수식 칠러를 장착한 마이크로터빈 구동 열병합시스템의 성능 해석 (Performance Analysis of Micro-turbine CHP System with Absorption Chiller)

  • 윤린;한승동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.540-545
    • /
    • 2007
  • The performance of microturbine CHP system equipped with an absorption chiller was analyzed by modelling of a microturbine and an absorption chiller. The microturbine having recuperator was simulated by the Brayton cycle model. The mass flow rate and available heat energy of the exhaust gas from the microtubune were simulated, and this results were utilized as input values for the generator of the absorption chiller. The absorption chiller is a single-effect air cooled type having solution heat exchanger. When heat input to the generator increased, the heat transfer rate and UA of the heat exchangers of the absorption chiller proportionally increased. Besides, the COP of the absorption chiller increased with increase of the heat input to the generator under the sufficient size of the evaporator condition. When the capacity of the CHP system increased from 30 to 60 kW, the mass flow rate of the LiBr for the absorption chiller increased by two times, and UA values for evaporator and condenser were increased by 3.9 and 3.4 times, respectively, under the same COP condition.

  • PDF

흡수식 칠러를 장착한 마이크로터빈 구동 열병합시스템의 성능 해석 (Performance Analysis of Microturbine CHP System with Absorption Chiller)

  • 윤린;한승동
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.486-491
    • /
    • 2008
  • The performance of a microturbine CHP system equipped with an absorption chiller was analyzed by modeling it. The microturbine with recuperator was simulated with the Brayton cycle model. The mass flow rate and available heat energy of the exhaust gas from the microturbine were simulated. These results were utilized as input values for the generator of the absorption chiller. The absorption chiller is a single-effect air cooled type with a solution heat exchanger. The heat input into the generator was proportional to the heat transfer rate and the UA values of the heat exchangers of the absorption chiller. Furthermore, the COP of the absorption chiller increased with respect to an increase of the heat input into the generator, under the sufficient evaporator capacity condition. When the capacity of the CHP system increased from 30 to 60 kW, the mass flow rate of the LiBr for the absorption chiller doubled, and the UA values for evaporator and condenser increased by factors of x3.9 and x3.4, respectively, under the same COP condition.

LiBr용액량 변화에 따른 수평다관 흡수기의 특성 연구 (An investigation of absorption phenomena in the horizontal staggered tube absorber for various LiBr solution flow rates)

  • 권율;윤상국
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.332-338
    • /
    • 1999
  • An experimental study of absorption phenomena of water vapor into LiBr solution was carried out to find out the optimum solution flow rate. The staggered bundle of horizontal absorption tubes, which are the same configuration as the commercial heat pump, were tested. The results showed that the heat transfer and absorption rate were enhanced with the increase of LiBr solution flow rate. Those values for different absorber pressures showed the same qualitative trends. The optimum flow rate of solution was obtained as three times of the designed flow rate.

  • PDF

수직관(수직관)내를 흘러내리는 액막식흡수기(液膜式吸收器)의 흡수(吸收) 및 열전달(熱傳達) 특성(特性) (제(第)3보(報), 증발기(蒸發器)의 냉동능력(冷凍能力)과 흡수기(吸收器)의 난방능력(暖房能力)) (Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (3rd. Report, Refrigerating Capacity in Evaporator and Heating Capacity in Absorber))

  • 엄기찬;카시와기 타카오;서정윤
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.175-181
    • /
    • 1994
  • This paper deals with the correlation of absorption rate in absorber and evaporation rate in evaporator. The evaporator consists of a copper tube of 10mm dia, and 600mm long and chilled water flowing through the tube is fed by the chilled water circulator. The flowrate of LiBr-water solution in the absorber plays a significant role in determining the magnitude of the heat transfer rate from chilled water to refrigerant There exists a flowrate of solution which has a maximum value of heat transfer. It is interesting to note that the absorption rate of absorber increases with increasing the heat transfer rate of the evaporator. Also, absorption rate increases with evaportation rate, and the ratio(the former/the other) depends on the inlet temperature of LiBr-water solution in the absorber. The heating capacity in the absorber is higher than the refrigerating capacity in the evaporator.

  • PDF

공랭형 수직평판 흡수기 액막에서의 열 및 물질전달에 관한 수치적 연구 (A Numerical Study on Heat and Mass Transfer in a Falling Film of Vertical Plate Absorber Cooled by Air)

  • 김선창;오명도;이재헌
    • 대한기계학회논문집
    • /
    • 제19권4호
    • /
    • pp.1071-1082
    • /
    • 1995
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of the LiBr aqueous solution which is cooled by cooling air. Heat flux at the wall is specified in terms of the heat transfer coefficient of cooling air and the cooling air temperature. Effects of operating conditions, such as the heat transfer coefficient, the cooling air temperature, the system pressure and the solution inlet concentration have been investigated in view of the local absorption mass flux and the total mass transfer rate. Effects of film thickness and film Reynolds number on the heat and mass transfer coefficients have been also estimated. Analyses for the constant wall temperature condition have been also carried out to examine the reliability of present numerical method by comparing with previous investigations.

수평관군 흡수기의 열 및 물질 전달특성에 관한 실험적 연구 (Experimental Study on Heat and Mass Transfer Characteristics in bundles of horizontal absorption tubes)

  • 설원실;정용욱;문춘근;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권3호
    • /
    • pp.113-120
    • /
    • 2000
  • On the absorber of absorption chiller/heater, LiBr solution at high concentration is sprinkled on a bundle of horizontal tube cooled by cooling water. In this case, the conditions of LiBr solution and cooling water have an influence on heat/mass transfer coefficient in this system. Therefor it is important to find optimal operation conditions of absorption chiller/heater to save energy. Heat and mass transfer coefficient increased with the increase of solution flow rate, and also heat and mass transfer rate increased but overall heat and mass transfer coefficient decreased by increasing the solution concentration within the experimental range. The superheating of the solution resulted in superior heat transfer character to a state of equilibrium from the point of heat flux and overall heat transfer coefficient.

  • PDF

암모니아-물 기포분사형 흡수과정에서의 흡수열 제거를 위한 열전달 특성 연구 (A Study on Heat Transfer Characteristics for Removal of Absorption Heat in Absorption Process of Ammonia-Water Bubble Mole)

  • 이재철;이기봉;전병희;이찬호;하종주;김성현
    • 청정기술
    • /
    • 제7권4호
    • /
    • pp.273-280
    • /
    • 2001
  • 흡수기는 흡수식 열펌프 시스템에서 중요한 구성요소일 뿐만 아니라 흡수기의 성능은 전체 시스템에 중요한 영향을 미친다. 본 연구에서는 기포분사형 흡수기에서의 암모니아기체의 흡수열의 효과적 제거를 위한 냉각수 방향으로의 열전달에 대해 실험적 연구를 수행하였다. 흡수기에 유입되는 암모니아 기체의 유속, 암모니아 수용액의 유속, 농도, 온도, 흡수기의 지름, 높이, 기체와 용액의 유입 방향등 여러 가지 변수에 대하여 열전달 성능의 특성을 살펴본 결과, 기체의 주입량, 용액의 주입량 증가는 열전달 성능 향상에 기여하며, 용액의 온도나 농도의 상승은 열전달 성능에 방해요소로 작용하였으며 흐름방향이 향류인 경우 열전달 성능에 향상이 있었다. 본 실험의 데이터를 이용하여 상관관계식을 유도하여 열전달에 대한 복잡한 관계를 일반화 하였다.

  • PDF

확산형 흡수식 냉동기용 기포펌프의 운전특성에 관한 연구 (Operating Characteristics of a Bubble Pump for Diffusion-Absorption Refrigerator)

  • 이현경;김선창;이재헌
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.878-887
    • /
    • 2001
  • Experimental investigation has been carried out to examine the operating characteristics of a bubble pump for diffusion absorption refrigerator. The effects of heat input and delivery height on generation rate of refrigerant vapor and circulation rate of solution have been investigated. as a result heat input and delivery height increase, circulation rate of solution increases. And the smaller the tube diameter, the larger the circulation rate of solution. Pumping ratio increases to a critical point and then decrease with the increase of heat input, and it increases with the increase in delivery height. In this paper, Marcus's analytical theory was also examined. It was found that the Marcus\`s analytical theory of a bubble pump was not appropriate for a bubble pump using ammonia aqueous solution as a working fluid.

  • PDF