• 제목/요약/키워드: Heat Test

검색결과 4,877건 처리시간 0.034초

압전 액츄에이터를 이용한 열전냉각 시스템 성능 향상에 관한 연구 (A Study on Enhancement of Thermoelectric Cooling System Performance by Piezoelectric Actuator)

  • 양호동;윤희성;오율권
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.13-19
    • /
    • 2009
  • The thermoelectric cooling system consisted of the thermoelectric module, a heat sink and a cooling fan, respectively. Also, the piezoelectric actuator was applied to improve the performance of thermoelectric cooling system and investigate the heat transfer phenomenon. The temperature distribution of test section was measured to investigate cooling characteristics of thermoelectric cooling system. The flow phenomenon of test section was visualized using visualization device. When the piezoelectric actuator was applied to the heat transfer process of thermoelectric cooling system, acoustic streaming was occurred in test section. The acoustic streaming was occurred forced convection flow, and was regularly formed the temperature distribution in test section. The results clearly show that the acoustic streaming is one of the prime effects to enhance the convection heat transfer and can enhance the performance of thermoelectric cooling system.

룸코너 시험기의 발열량 측정에 대한 불확도 산정 (Calculation of Uncertainty in Measuring Heat Release Rate in Room Corner Test)

  • 노광철;김치훈;이승철;이덕희
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.16-22
    • /
    • 2012
  • 화재시험에 있어서 정확한 발열량의 측정은 시험체의 화재 안정성을 결정하기 위한 중요한 정보이다. 발열량 측정값은 측정 인자들의 오차에 기인하여 영향을 받는다. 본 연구에서는 한국철도기술연구원에 설치된 룸코너 시험기에 대한 불확도의 인자를 분석하였고 이를 이용하여 KTX 내장재 화재시험의 발열량 측정 불확도를 계산하였다. 화재 발열량 불확도 계산 결과, 화재시작단계에서 불확도가 매우 높은 값으로 나타났고 화재가 성장하면서 불확도는 점차적으로 감소하였다. 불확도 인자들 중 산소 농도가 발열량 측정 불확도에 가장 크게 기여하는 것으로 나타냈다.

Thermomechanical Properties of Thermal-Stress Relief Type of Functionally Gradient Materials

  • Watanabe, Ryuzo
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 1993년도 추계학술강연 및 발표대회강연 및 발표논문 초록집
    • /
    • pp.2-2
    • /
    • 1993
  • The present status of the thennomechanica1 evaluation of functionally gradient materials(FGMs) for space plane application was reviewed, in which research activities and the cooperation of the national project team organized to study FGM science were demonstrated. The project team was divided into three working groups; de singing, processing and evaluation, each of which had their own tasks in the project cooperation. The testings details of the various thennomechanical tests for the FGM samples fabricated by the processing groups were described, along with their corresponding heating conditions of the real environments in the space plane application. For small-sized samples, laser beam heating test and burner heating test were well applied to study the heat shielding and heat resisting properties. Arc-heated wind tunnel test and high temperature!high velocity gas flow test were used for large-sized panel assemblies having cooling structures. The criteria for the evaluation of the heat shielding and heat resisting properties of the FGMs, as well as a crack activation mechanism in their differential temperature heating, were proposed on the basis of the observation in the burner heating test.

  • PDF

모세관을 이용한 멀티형 열펌프의 신뢰성에 관한 실험적 연구 (An Experimental Stuff on the Performance of Multi-type Heat Pump using Capillary Tubes)

  • 권영철;장근선;이윤수;김대훈;전용호;이상재
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.749-755
    • /
    • 2002
  • In order to develop a multi-type heat pump system with two indoor units of non-uniform capacities, the optimum refrigerant circuit was developed using capillary tubes. The refrigerant circuit was composed of four main parts, a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The system characteristics of multi-type heat pump was investigated through the rating test and the reliability test, using the multi-type psy-chrometric calorimeter. The results of the rating test showed that the capacity of the multi-type heat pump was about 93% of the design value. In particular, the capacity of cooling single mode was about 13% higher than the design value, and the capacity of heating multi mode was about 5% higher than the design value. The reliability of the multi-type heat pump was verified by various reliability tests (overload, extension tube, freeze up, under/over charging, sweat, flood back). The optimal amount of refrigerant charge and compressor capacity were determined from the present work.

해양플랜트 복사열 차폐막의 차폐성능에 관한 연구 (Study on Performance of Radiant Heat Shields for Offshore Installations)

  • 김봉주
    • 한국해양공학회지
    • /
    • 제33권4호
    • /
    • pp.330-339
    • /
    • 2019
  • Radiant heat shields are normally installed on offshore oil and gas platforms to protect personnel, equipment, and structures from the thermal radiation emitted by a flare system. A heat shield should be individually designed to reduce the thermal radiation to the target level, and then manufactured and installed after the performance verification. However, in general, a heat shield is designed and manufactured by trial and error based on the performance test. For this reason, it is difficult to develop and design radiant heat shields in the Korean shipbuilding and marine equipment industry because of the lack of performance test data and limited experience. In the present study, the results of experiments conducted to verify the performances of radiant heat shields were analyzed, and the thermal radiation characteristics and performance characteristics of the radiant heat shields were investigated. The insights and conclusions developed in the present study will be useful in terms of the design and development of radiant heat shield, as well as in their performance verification tests.

Specific Heat Measurement of Insulating Material using Heat Diffusion Method

  • Choi, Yeon-Suk;Kim, Dong-Lak
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.32-35
    • /
    • 2012
  • The objective of the present work is to develop a precise instrument for measuring the thermal property of insulating material over a temperature range from 30 K to near room temperature by utilizing a cryocooler. The instrument consists of two thermal links, a test sample, heat sink, heat source and vacuum vessel. The cold head of the cryocooler as a heat sink is thermally anchored to the thermal link and used to bring the apparatus to a desired temperature in a vacuum chamber. An electric heater as a heat source is placed in the middle of test sample for generating uniform heat flux. The entire apparatus is covered by thermal shields and wrapped in multi-layer insulation to minimize thermal radiation in a vacuum chamber. For a supplied heat flux the temperature distribution in the insulating material is measured in steady and transient state. The thermal conductivity of insulating material is measured from temperature difference for a given heat flux. In addition, the specific heat of insulating material is obtained by solving one-dimensional heat diffusion equation.

잠열재를 사용한 결합재의 수화발열 특성에 관한 실험적 연구 (Experimental Study on the Generation of Hydration Heat of Binder using Latent Heat Material)

  • 김용로;김도수;길배수;김욱종;이도범
    • 한국건축시공학회지
    • /
    • 제9권3호
    • /
    • pp.103-107
    • /
    • 2009
  • It is necessary to develop a new technology for effectively controlling thermal crack caused hydration heat according to the increasing construction of large size massive concrete structures such as mat foundation of high-rise building. Therefore, to develop a new technology for reducing hydration heat of large size massive concrete in this study, it was investigated hydration heat generation properties of binder using latent heat materials. As a test result, it was confirmed that latent heat materials were advanced on the reduction of hydration heat and control of thermal crack. It is expected to be applied as the excellent technology on the management of hydration heat and thermal crack in large size massive concrete structures.

친수지역 강변여과수 열원을 활용한 냉난방시스템 개발 (Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront)

  • 조용;김대근;문종필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

수평 평활관 및 전열촉진관내 대체 냉매 R-407C의 응축 열전달 특성에 관한 연구 (Heat Transfer Characteristics of R-407C During Condensing Inside Horizontal Smooth and Micro-Fin Tubes)

  • 노건상;오후규
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.210-217
    • /
    • 1999
  • This paper reports the experimental results on heat transfer characteristics of R-22 and R-407C(HFC-32/125/134a 23/25/52 wt%) condensing inside horizontal smooth and finned tubes. The test condensers used In the study are double pipe heat exchangers of 7.5 mm ID, 9.5 mm OD smooth tube, and 60 finned micro-fin tube with 8.53 mm ID, 9.53 mm OD. Each of these tubes was 4 000 mm long tubes connected with an U-bend. These U type two-path test tubes are divided In 8 local test sections for the identification of the local condensing heat transfer characterisitcs and pressure drop, U-bend effects on condensing flows. Inlet quality is maintained 1.0, and refrigerant mass velocity is varied from 102.0 to $301.0kg/m^2{\cdot}s$. From the results, it was found that the pressure drop of the R-407C Increased, and heat transfer coefficient decreased compared to those of R-22. In comparison condensing heat transfer characteristics of micro-fm tube with those of smooth tube, increasing of condensing heat transfer coefficient was found outstanding compared to the increasing ratio of pressure drop. Furthermore, pressure drop In U-bend showed at most a 30 % compared to the total pressure drop in the test section.

구획공간 화재의 열유속 특성 - 축소 실험 (Characteristics of Heat Flux in a Compartment Fire - Reduced Scale Test)

  • 김성찬;고권현
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.128-133
    • /
    • 2011
  • 본 연구는 구획공간화재에서 화재특성과 위치에 따른 공간내부의 열유속 특성을 파악하기 위해 ISO-9705 표준화재실의 40 % 크기로 축소된 공간에서 화재 실험을 수행하였다. 열유속의 측정은 Schimit-Boelter type 열유속계를 이용하였으며 화재실의 내부와 출입구쪽의 중앙바닥면에서 열유속이 각각 측정되었다. 실험에 사용된 연료는 천연가스, 헵탄, 톨루엔, 에탄올, 폴리스틸렌 등이다. 실험결과 화재발열량과 상층부의 온도가 증가함에 따라 화재실 내부 바닥에서의 열유속이 출입구쪽에 비해 상대적으로 높게 나타났다. 또한 그을음의 생성이 많은 연료일수록 화재실 바닥면에서 열유속의 공간적인 편차가 상대적으로 크게 나타났다. 본 연구를 통해 공간내 하층부에서의 열유속 분포는 화재가 성장함에 따라 화염 및 상층부에서 방출되는 복사열과 밀접한 관계가 있고 이는 상층부의 온도뿐만 아니라 연소가스의 조성이나 그을음 농도(soot concentration), 환기조건 등과 같은 화재특성에 크게 영향을 받는다는 사실을 파악하였다.