• Title/Summary/Keyword: Heat Storage Tank

Search Result 294, Processing Time 0.024 seconds

Fabrication and Characteristics of 150ℓ Class Hydrogen Tank Using Hydrogen Storage Alloy (수소저항합금을 이용한 150ℓ급 수소저장용기의 제작과 특성에 관한 연구)

  • Kang, Kll-Ku;Gang, Sei-Sun;Kwon, Ho-Young;Lee, Rhim-Youl
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.2
    • /
    • pp.110-118
    • /
    • 2002
  • The hydrogen storage vessel having a good heat conductivity along with a simple structure and a low cost for these alloys was designed and manufactured, and then its characteristic properties were studied in this study. The various parts in hydrogen storage vessel consisted of copper pipes and stainless steel of 250 mesh reached the setting temperature after 4~5 minutes, which indicated that storage vessel had a good heat conductivity that was required in application. And also the storage vessel had a good property of hydrogen transport considering that the reaction time between hydrogen and rare-earth metal alloys in storage vessel was found to be within 10 min at $18^{\circ}C$ under 10 atmospheric pressure. It showed that the average capacity of discharged hydrogen volume was found to be $120{\ell}$ for $MmNi_{4.5}Mn_{0.5}$ under discharging conditions of $40^{\circ}C{\sim}80^{\circ}C$ at a constant flow rate of $5{\ell}$/min. It was found that the optimum discharging temperature for obtaining an appropriate pressure of 3atm was determined to be $60^{\circ}C$ for $MmNi_{4.5}Mn_{0.5}$ hydrogen storage alloy.

A Heat Exchanging Characteristics of Organic Rankine Cycle for Waste Heat Recovery of Coal Fired Power Plant (화력발전용 복수기 폐열 회수를 위한 유기랭킨사이클 시스템 열교환 특성 해석)

  • Jeong, Jinhee;Im, Seokyeon;Kim, Beomjoo;Yu, Sangseok
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.1
    • /
    • pp.64-70
    • /
    • 2015
  • Organic Rankine cycle (ORC) is an useful cycle for power generation system with low temperature heat sources ($80{\sim}400^{\circ}C$). Since the boiling point of operating fluid is low, the system is used to recover the low temperature heat source of waste heat energy. In this study, a ORC with R134a is applied to recover the waste energy of condenser of coal fired power plant. A system model is developed via Thermolib$^{(R)}$ under Simulink/MATLAB environment. The model is composed of a refrigerant heat exchanger for heat recovery from coal fired condenser, a drum, turbine, heat exchanger for ORC heat rejection, storage tank, water recirculation pump and water drip pump. System analysis parameters were heat recovery capacity, type of refrigerants, and types of turbines. The simulation model is used to analyze the heat recovery capacity of ORC power system. As a result, increasing the overall heat transfer coefficient to become the largest of turbine power is the most economical.

A Study on the Thermal Analysis for the Robotic Arm of the Cord Blood Storage Tank (제대혈 용기 내부 로봇 암의 열해석에 관한 연구)

  • Yun, Sang-Kook;You, Sam-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.724-729
    • /
    • 2008
  • Umbilical cord blood has been recently considered an attractive potential alternative as a source of stem cell transplantation to curing diseases such as leukemia, cancers, immune disorders. Normally the stored system of the umbilical cord blood specimen is equipped with a computer-controlled robotic arm that enables the samples to locate the identification places in liquid nitrogen tank at regulated temperature as about $-196^{\circ}C$. As the half of robotic arm is in the air and the rest part is submerged in liquid nitrogen, the temperature of robotic arm varies from ambient to liquid nitrogen temperature. In this study the temperature variation of upper part of arm above tank lid was thermally analysed by using the commercial code of Ansys. The result of analysis was that the upper part of robotic arm was seriously frozen due to heat transfer from liquid nitrogen as low as -$120^{\circ}C$. In order to solve the frost problem of robotic arm, small PTFE tube block as resistance material was introduced into the lower part of tank lid instead of the whole stainless steel(SUS) robotic arm. The results showed that the temperature of robotic arm above the lid was higher enough, and this method would be one of the very effective measure to solve the problem.

Adiabatic Performance of Layered Insulating Materials for Bulk LH2 Storage Tanks (대용량 액체 수소 저장탱크를 위한 다층단열재의 단열성능 분석)

  • KIM, KYEONGHO;SHIN, DONGHWAN;KIM, YONGCHAN;KARNG, SARNG WOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.642-650
    • /
    • 2016
  • One of the most feasible solution for reducing the excessive energy consumption and carbon dioxide emission is usage of more efficient fuel such as hydrogen. As is well known, there are three viable technologies for storing hydrogen fuel: compressed gas, metal hydride absorption, and cryogenic liquid. In these technologies, the storage for liquid hydrogen has better energy density by weight than other storage methods. However, the cryogenic liquid storage has a significant disadvantage of boiling losses. That is, high performance of thermal insulation systems must be studied for reducing the boiling losses. This paper presents an experimental study on the effective thermal conductivities of the composite layered insulation with aerogel blankets($Cryogel^{(R)}$ Z and $Pyrogel^{(R)}$ XT-E) and Multi-layer insulation(MLI). The aerogel blankets are known as high porous materials and the good insulators within a soft vacuum range($10^{-3}{\sim}1$ Torr). Also, MLI is known as the best insulator within a high vacuum range(<$10^{-6}{\sim}10^{-3}$ Torr). A vertical axial cryogenic experimental apparatus was designed to investigate the thermal performance of the composite layered insulators under cryogenic conditions as well as consist of a cold mass tank, a heat absorber, annular vacuum space, and an insulators space. The composite insulators were laminated in the insulator space that height was 50 mm. In this study, the effective thermal conductivities of the materials were evaluated by measuring boil-off rate of liquid nitrogen and liquid argon in the cold mass tank.

A Simulation for the Stratified Thermal Storage System in Residential Solar Energy Application (주거용 태양열 성층축열시스템의 시뮬레이션)

  • Pak, Ee-Tong;Yoo, Ho-Seon
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.44-52
    • /
    • 1991
  • The benefits of thermal stratification in sensible heat storage systems has been considered and studying by several investigators. In this paper, the basic data which is hard to obtain normally through the experiment were obtainable through the computer simulation. The major objectives of the study were to assess the benefits of stratified storage in residential solar water heating application and to suggest the optimum design parameters. From the computer simulation, following results were obtained. 1. The solar load fraction increases with increasing the number of tank segments. In these simulation, the magnitude of the improvement was about 10%. 2. The solar load fraction increases when the ratio of diameter to height of the tank(H/D) increases to 3, but H/D exceed 3 then, the solar load fraction decreases. In these simulation, the magnitude of the improvement was about 3%. 3. Increasing the collector flow rate slightly improved the performance of the mixed storage system(Node=1). But, for the stratified storage system(Node=N), the solar load fraction increases with decreasing flow rate until the point is reached at which the collector outlet temperature reaches the boiloff limit of $100^{\circ}C$ over some portion of the simulation period.

  • PDF

Relation of Concrete Setting Characteristic and Lateral Pressure in Mass Concrete Wall (매스콘크리트 벽체에서 콘크리트 응결 특성과 측압과의 관계)

  • 박찬규;유재현;백승준;정재홍;진용만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.935-938
    • /
    • 2001
  • This paper reports the relation of concrete setting characteristic and lateral pressure in mass concrete wall such as side wall of LNG underground storage tank. In order to estimate the lateral pressure, initial setting time of low heat cement concrete with type of mineral admixture was measured for three concrete mixtures(W/P=41.6%) containing limestone powder, fly ash, and slag powder. As a result, the lateral pressure of the concrete containing limestone powder was the smallest than those of other concretes as well as the initial setting time.

  • PDF

An Experimental Study on the Freezing Temperature of Admixture Agent for Concrete (콘크리트용 혼화제의 동결온도에 관한 실험적 연구)

  • 한경익;이건철;이진규;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.48-51
    • /
    • 1996
  • Recently, frost damage of storage tank for admixture agent caused by low temperature in winter and quality deterioration of admixture agent ofen happened. But, many problems are caused because of no applicable regulations of admixture agent facility and so on. Therefore, this study presents the reference data about using and quality control of admixture agent in practice and the judgement data about working out a counter plan of suitable heat insulation of injecion equipment of admixture agent exposed at outside in winter by measuring the freezing point of admixture agent for concrete.

  • PDF

Analysis for DME FPSO Storage Tank and Experimental Study on the DME Evaporation Rate by Rolling Motion of Ship (DME FPSO선박의 탱크해석 및 Rolling 유동에 따른 증발 실험연구)

  • Yun, Sangkook;Cho, Wonjun;Baek, Youngsoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1010-1015
    • /
    • 2012
  • DME(Dimethyl ether) is the one of the massive energy sources synthesized from natural gas. KOGAS has already developed the commercial-scale production plant of DME and has been doing to obtain overseas resources to meet the domestic needs. This paper presents the DME storage tank design criteria by stress and strain analysis, and the experimental study on the evaporation phenomena of DME by thermal intake and physical rolling movement of DME FPSO or cargo vessel, because the various moving motions along with heat intake cause the evaporation of low temperature liquid. The experimental result shows that the evaporation rate was increased with larger rolling degree and higher liquid level. The rolling motion leads to evaporate about 20% increase with 15 degree rolling based on the evaporation quantity without rolling.

Performance Analysis of Energy-Slab Ground-Coupled Heat Exchanger (에너지슬래브 지중열교환기의 성능 분석)

  • Choi, Jong-Min;Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.487-496
    • /
    • 2012
  • Recently, utilization of building foundations as ground-coupled heat exchangers has attracted much attention because they reduce the cost and enhance the heat transfer. The objective of this study is to evaluate the performance of energy-slab ground-coupled heat exchanger installed in a commercial building. In order to demonstrate the energy transfer characteristics of the energy-slab, experiments were conducted from October 2010 to September 2011. The 1-year measurement results showed that the mean EWTs of brine returning from the energy-slab were $9.6^{\circ}C$ in heating season and $24.9^{\circ}C$ in cooling season, which were in a range of design target temperatures. In addition, the geothermal heat pump system with the energy-slab showed on-off operation according to the setting temperatures of secondary fluid in water storage tank. The results also showed that the energy-slab extracted heat of 198.6 kW from the ground and injected heat of 318.9 kW to the ground, respectively.

A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses (공동주택용 태양열원 급탕시스템의 운전성능 연구)

  • 이윤규;황인주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.