1 |
Man, Y., Yang, H., Diao, N., Liu, J., and Fang, Z., 2010, A new model and analytical solutions for borehole and pile ground heat exchangers, International Journal of Heat and Mass Transfer, Vol. 53, pp. 2593-2601.
DOI
|
2 |
Baek, S. K., An, H. J., and Lim, S. K., 2007, Development of ground heat exchangers installed in building foundation, Proceedings of the SAREK, pp. 277-282.
|
3 |
Yu, H. K. and Bae, S. H., 2010, Performance monitoring study of building integrated geothermal system in winter, Transactions of the Korea Society of Geothermal Energy Engineers, Vol. 6, No. 1, pp. 23-28.
과학기술학회마을
|
4 |
Min, S., Lee, C., Park, M., Koh, H., and Choi, H., 2010, Numerical study of heat transfer efficiency, performance and mechanical behavior induced by thermal stress of energy pile, Transactions of the Korea Society of Geothermal Energy Engineers, Vol. 6, No. 2, pp. 9-13.
|
5 |
Sohn, B. and Choi, J. M., 2012, Performance prediction of geothermal heat pump(GHP) system with energy piles using simulation approach, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 24, No. 2, pp. 155-163.
과학기술학회마을
DOI
ScienceOn
|
6 |
Katsura, T., Nagano, K., and Takeda, S., 2008, Method of calculation of the ground temperature for multiple ground heat exchangers, Applied Thermal Engineering, Vol. 28, pp. 1995-2004.
DOI
|
7 |
Wood, C. J., Liu, H., and Riffat, S. B., 2010, An investigation of the heat pump performance and ground temperature of a piled foundation heat exchanger system for a residential building, Energy, Vol. 35, pp. 4932-4940.
DOI
|
8 |
Hwang, K. I., Woo, S. W., Kim, J. H., Shin, S. H., and Kim, Y. S., 2007, A study on the seasonal performances evaluation of the horizontal- type geothermal heat exchanger installed in the foundation slabs of complex building, Journal of the Korean Solar Energy Society, Vol. 27, No. 2, pp. 11-17.
과학기술학회마을
|
9 |
Choi, J. M., 2012, Heating and cooling performance of a ground coupled heat pump system with energy-slab, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 24, No. 2, pp. 196-203.
과학기술학회마을
DOI
|
10 |
Kline, S. J., 1985, The purpose of uncertainty analysis, J. Fluids Engineering, Vol. 107, pp. 153-160.
DOI
|
11 |
Laloui, L., Nuth, M., and Vulliet, L., 2006, Experimental and numerical investigations of the behaviour of a heat exchanger pile, Int. J. for Numerical and Analytical Methods in Geomechanics, Vol. 30, pp. 763-781.
DOI
|
12 |
Sohn, B. H., Cho, C. S., Shin, H. J. and An, H. J., 2005, Cooling and heating performance evaluation of a GSHP system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 1, pp. 71-81.
과학기술학회마을
|
13 |
Gao, J., Zhang, X., Liu, J., Li, S. K., and Yang, J., 2008, Thermal performance and ground temperature of vertical pile-foundation heat exchangers: a case study, Applied Thermal Engineering, Vol. 28, pp. 2295-2304.
DOI
|
14 |
Hamada, Y., Saitoh, H., Nakamura, M., Kubota, H., and Ochifuji, K., 2007, Field performance of an energy pile system for space heating, Energy and Buildings, Vol. 39, pp. 517-524.
DOI
|
15 |
Zhang, X., Liu, J., Gao, J., and Li, K., 2008, Research on ground temperature restoration characteristics of large-scale ground source heat pump system, International Journal of Air-Conditioning and Refrigeration, Vol. 16, No. 4, pp. 109-116.
|