• 제목/요약/키워드: Head-roll

검색결과 73건 처리시간 0.028초

북미 법규 강화를 고려한 국내 자동차의 천정강도 시험특성에 관한 연구 (A Study on the Characteristics of Domestic Vehicle on the Roof Crush Test Considering the Enhanced Safety Standard, FMVSS 216)

  • 김은희;이재광;이문구;홍민성
    • 한국생산제조학회지
    • /
    • 제18권4호
    • /
    • pp.348-354
    • /
    • 2009
  • In order to reduce the risk of roll over crash, one of the greatest risk events, National Highway Traffic Safety Administration(NHTSA) issued Notice of Proposed Rulemaking(NPRM) enhancing the safety standard on roof crush resistance, FMVSS No. 216 and changing some part of the test procedure. According to this NPRM, the boundary Gross Vehicle Weight Rating(GVWR) of the vehicles applied by this standard is extended from 2,722kg(6000 lb) to 4,536 kg(10000 lb) and the applied test force is increased from 1.5 times to 2.5 times of Unloaded Vehicle Weight (UVW). Also the current limit on the amount of roof crush, 127mm(5 inch), is replaced with a new requirement of maintaining enough headroom without touching the head of a seated 50% male dummy. In this paper, we carried out the rollover crash test on some domestic cars and investigated their safety due to the KMVSS No. 92 and the enhanced safety standard, FMVSS No. 216, respectively. The result shows that most of them can satisfy the new standards but further tests will be necessary, especially for heavier cars.

  • PDF

Development of Motion Control Camera Design Based on Wires with Anti-sway Method

  • Kim, Tae-Rim;Jung, Sung-Young;Baek, Gyeong-Dong;Kim, Sung-Shin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제10권1호
    • /
    • pp.25-30
    • /
    • 2010
  • This paper is proposed about three axis motion control camera design method based on wires. Original motion control camera consists of track, boom, L-Head, Camera and so on and is enormous and expensive. But proposed motion control camera adjusts wire length using encoders and motors. And position control use position based straight line of straight-line move method for moving precise position. Proposed simple design is able to use various place and inexpensive than original motion control camera. But, camera was vibrated and rotated due to basic property of wire. So we proposed solutions that connected method of wire and using a tensional object for reducing rotation. For proposed algorithm verification, we realized three axis motion control camera based on wire and measured oscillation while moving same trace. We confirmed the results that standard deviation of oscillation was reduced 4.93 degree than before design method.

M-shaped 파형을 이용한 작은 액적의 잉크젯 프린팅 (Inkjet Printing of Small Droplets Using M-shaped Waveforms)

  • 홍송은;최지호;김기은;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.51-56
    • /
    • 2021
  • Using an inkjet printing process, we have investigated a droplet formation of poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) near the orifice of a piezoelectric inkjet head. With an attempt to form the smallest droplet without any satellites, we have applied various waveforms such as the unipolar, bipolar, and M-shaped waveforms. It is found that the droplet velocity and volume vary depending sensitively on the waveform width and voltage. Of those, the M-shaped waveform is shown to provide the smallest droplet volume, followed by the bipolar and then unipolar waveforms. The droplet printed on a PET film roll by the M-shaped waveform has the diameter as small as 46.1 ㎛. It is likely that the second short unipolar in the M-shape waveform increases the droplet velocity gradient, rendering the droplet smaller.

정상성인에서 정적 균형 제어 시 다양한 조건에 따른 하퇴 근육 활성도의 특성 (Electromyographic Activities of Lower Leg Muscles During Static Balance Control in Normal Adults)

  • 우영근;박지원;최종덕;황지혜;김연희
    • 한국전문물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.35-45
    • /
    • 2004
  • The purpose of this study was to investigate the correlation and characteristics between electromyographic (EMG) activities of lower leg muscles and the posturographic assessment of static balance control in normal adults. Twenty-four young, healthy adults(12 males, 12 females) participated in the study. Center of pressure (COP) parameters were obtained using force platform as total path distance, total sway area, X mean frequency and Y mean frequency for 20 seconds in the following conditions: (1) comfortable standing with eyes opened or closed, (2) uncomfortable standing (feet together) with eyes opened or closed, (3) virtual moving surround delivered using Head mount display (HMD) with four different moving patterns. The virtual moving patterns consisted of close-far, superior-inferior tilting (pitch), right-left tilting (roll), and horizontal rotation (yaw) movements. Surface electromyographic activites were recorded on the tibialis anterior, peroneus longus, medial and lateral heads of gastrocnemius muscles under each condition. Correlation between the posturographic measures and EMG activities were evaluated. Total path distance and total sway area of COP were significantly increased during uncomfortable standing. EMG activity of tibialis anterior was significantly more during uncomfortable standing and virtual moving surround stimulation than during comfortable standing. Total path distance and sway area of COP during comfortable standing with closed eyes showed significant positive correlation with the EMG activities of the lateral head of gastrocnemius muscle. Total path distances and total sway area of COP during muscle. Total path distances and total sway area of COP during presentation of virtual moving surround also had significant positive correlations with EMG activities of the lateral head of gastrocnemius muscle under close-far movement.

  • PDF

인공 신경망을 이용한 보청기용 실시간 환경분류 알고리즘 (Real Time Environmental Classification Algorithm Using Neural Network for Hearing Aids)

  • 서상완;육순현;남경원;한종희;권세윤;홍성화;김동욱;이상민;장동표;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권1호
    • /
    • pp.8-13
    • /
    • 2013
  • Persons with sensorineural hearing impairment have troubles in hearing at noisy environments because of their deteriorated hearing levels and low-spectral resolution of the auditory system and therefore, they use hearing aids to compensate weakened hearing abilities. Various algorithms for hearing loss compensation and environmental noise reduction have been implemented in the hearing aid; however, the performance of these algorithms vary in accordance with external sound situations and therefore, it is important to tune the operation of the hearing aid appropriately in accordance with a wide variety of sound situations. In this study, a sound classification algorithm that can be applied to the hearing aid was suggested. The proposed algorithm can classify the different types of speech situations into four categories: 1) speech-only, 2) noise-only, 3) speech-in-noise, and 4) music-only. The proposed classification algorithm consists of two sub-parts: a feature extractor and a speech situation classifier. The former extracts seven characteristic features - short time energy and zero crossing rate in the time domain; spectral centroid, spectral flux and spectral roll-off in the frequency domain; mel frequency cepstral coefficients and power values of mel bands - from the recent input signals of two microphones, and the latter classifies the current speech situation. The experimental results showed that the proposed algorithm could classify the kinds of speech situations with an accuracy of over 94.4%. Based on these results, we believe that the proposed algorithm can be applied to the hearing aid to improve speech intelligibility in noisy environments.

다단 후판압연에서 평면형상 및 실수율 고찰을 위한 수치적, 실험적 연구 (Numerical and Experimental Approach to Investigate Plane-view Shape and Crop Loss in Multistage Plate Rolling)

  • 변상민
    • 대한기계학회논문집A
    • /
    • 제37권9호
    • /
    • pp.1117-1125
    • /
    • 2013
  • 후판압연 중에 발생하는 소재의 평면형상과 손실량을 정확하게 고찰할 수 있는 유한요소에 기초한 접근법을 제시한다. 압연의 패스 수가 증가함에 따른 소재의 선, 후단부의 형상을 연속적으로 모사할 수 있는 3 차원 유한요소모델을 도입하였다. 본 모델의 가장 큰 특징은 다단 압연을 할 수 있도록 롤 갭이 순차적으로 감소됨에 따라 소재의 압연 방향을 바꾸면서 중단 없이 해석 가능하다는데 있다. 유한요소해석에서 요구되는 재료상수는 열간 인장시험에 의해서 실험적으로 얻어졌다. 제시된 유한요소모델의 유용성을 입증하기 위해서 파이롯트 열간 판압연 시험을 실시하였다. 제시된 유한요소모델로 계산된 평면형상과 손실량이 판압연 시험에서 실제 측정된 양과 매우 잘 일치하는 결과를 얻었다. 제시된 모델로 예측한 손실량과 판압연 시험에서 측정한 양 사이의 오차는 5% 이하로 나타났다.

뇌기능 장애 환자의 가상 환경 움직임(Virtual Moving Surround) 자극에 따른 자세 균형 제어 (Postural Control During Virtual Moving Surround Stimulation in Patients with Brain Injury)

  • 김연희;최종덕;이성범;김종윤;이석준;박찬희;김남균
    • 감성과학
    • /
    • 제5권4호
    • /
    • pp.67-75
    • /
    • 2002
  • 뇌기능 장애 환자에서 자세균형 제어능력의 저하는 보행 및 일상생활동작 수행 등에 어려움을 초래하며 이에 대한 정확한 평가 및 치료를 위하여 일상의 환경변화와 유사한 상황을 제공하고 이에 따른 자세균형 조절 능력을 파악하는 것이 중요하다. 본 연구는 뇌기능 장애 환자에서 가상적 움직이는 환경에 따른 자세균형 조절 기능을 정확히 평가하고 환경의 움직임이 자세균형 조절에 미치는 영향을 분석하였다. 15명의 뇌기능 장애 환자들과 정상인 15명을 대상으로 실생활과 유사한 환경의 조성을 위하여 HMD를 이용한 가상 환경 움직임(Virtual Moving Surround)을 네 가지 다른 패턴으로 제공하였다. 자세동요의 정도는 힘판을 이용하여 신체압력중심의 변화를 전체이동거리, 동요주파수, 최대 빈도 COP 위치로 측정하였으며 가상 환경의 차이에 따른 변화를 비교 분석하였다. 연구결과 검사 재검사 신뢰도평가에서 일관된 분석결과를 나타냈고 뇌 기능장애 환자와 정상인의 분석에서는 두 그룹간의 차이를 확인할 수 있었다. 특히 전후로 빠르게 변하는 가상 환경에서 가장 큰 자세동요를 나타내었고 통계적으로 유의한 차이가 있었다. 본 연구를 통해 뇌기능 장애 환자에서 가상 환경 변화가 자세균형 조절에 미치는 영향을 확인할 수 있었으며 이러한 환자들을 위한 치료와 평가 환경 조성 등에도 유용한 자료로 쓰일 수 있을 것으로 사료된다

  • PDF

조구등(釣鉤藤)이 일측(一側) 전정기관(前庭器官) 손상(損像) 흰쥐의 전정보상(前庭補償)에 미치는 영향(影響) (Effects of Uncaria Rhynchophylla on Vestibular Compensation in Unilateral Labyrinthectomized Rats)

  • 송진호;이성호;김민선;손인철;박병림;김재효
    • 대한한의학회지
    • /
    • 제20권3호
    • /
    • pp.66-76
    • /
    • 1999
  • The purpose of this study was to asses the etlect of Uncaria rhynchophylla (UR). one of the oriental herbs having a capability to block calcium channels, on affecting vestibular compensation (VC) in Sprague - Dawley rats. Animals were divided into a drug treatment group receiving, UR per oral for 10 days preceding unilateral labyrinthectomy (ULX) and a control group with saline ingestion, To evaluate behavioral changes. horizontal spontaneous nystagmus (SN) and roll head tilt (RHT) were recorded by a video camem with zoom lens in the course of vestibular compensation (VC). Immunohistochemical staining was performed by conventional ABC method to visualize cFos-like immunoreactive (cFLI) neurons in the medial vestibular nuclei (MVN) and cFLI cells were counted by image analyzer. Bodyweight was increased significantly, about 35g, by UR treatment for 10 clays before ULX. Compared with the control group, the drug group showed significant reduction of RHT 6 hrs after ULX as well as fast disappearance of SN at early stages of vestibular compensation. Also, recovery of the spatial and temporal cFLI expressions in the bilateral MVN was accelerated 24 hrs after ULX. These results suggest that Uncaria rhynchophyila has a beneficial effect to ameliorate vestibular compensation in unilateral labryinthectomized rats.

  • PDF

Efficient way to clean Solder Printer Nozzles

  • Kim, Young-Min;Kim, Chi-Su
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권11호
    • /
    • pp.115-121
    • /
    • 2022
  • 표면실장기술(SMT)에서 솔더 크림을 바르는 장비인 스크린 프린터는 패드가 작아지면서 도포 불량이 많이 발생한다. 이를 해결하기 위해 최근에는 젯 프린터를 사용하고 있다. 그런데 젯 프린터 헤드에 적용하는 밸브의 끝단 노즐을 깨끗하게 청소하지 않으면 과납이나 오도포가 발생한다. 이를 방지하기 위해서는 노즐을 주기적으로 청소해줘야 한다. 본 논문에서는 젯 프린터의 안정적인 솔더 크림 도포를 위하여 기존 기술보다 더욱 안정적으로 청소하는 방법을 제시하였다. 이 방법은 35mm 폭의 무진천을 재단하여 롤 형태로 감아 놓고, 반대쪽에 DC 기어드 모터로 회전시켜 닦는다. 그 결과 약 2,000회 도팅 주기로 청소를 했을 때 노즐 표면에 솔더 페이스트가 남지 않고 잘 닦이는 것을 확인하였다.

로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가 (Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife)

  • 정영준;정재홍;임광채;조은주
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 목 적: 로봇 사이버나이프에서 환자의 움직임에 의한 기준점의 위치변화 오차가 위치인식시스템(target location system, TLS) 을 통하여 targeting error값이 정확히 보정(correction)되는지 평가하고자 한다. 대상 및 방법: 본 실험은 targeting의 정확성을 분석하기 위해 head and neck팬텀에 Gafchromic 필름(MD-55)을 삽입한 후, 사이버나이프(CyberKnife Robotic Radiosurgery System G4, Accuray, US)의 6 MV X선을 조사하였다. 필름 분석은 Accuray사에서 제공하는 End to End (E2E) 프로그램을 이용하였다. 기준점의 위치에서 x, y, z방향으로 $0{\pm}0.2\;mm$, roll, pitch, yaw방향으로 $0{\pm}0.2^{\circ}$ 이내로 유지하여 12회 조사한 대조군과 인위적으로 움직임을 주어 실험을 시행한 6회의 실험군의 targeting 오차를 구하고, 대조군과 실험군의 평균값에 대한 유의성을 t-검정을 통해 분석하였다. 또한, gamma-index method (dose difference: 3%)를 통해 2차원적 선량분포의 일치성을 distance to agreement (DTA)를 각각 1 mm, 1.5 mm, 2 mm로 달리하여 정량화하고, 비교 분석하였다. 결 과: E2E test 시행 결과, 기준 필름의 targeting 평균오차 0.405 mm, 표준편차 0.069 mm, 실험 필름의 평균오차 0.413 mm, 표준편차 0.121 mm으로 나왔으며, t-검정 결과 유의확률 P=0.836 (신뢰구간 95%)으로 두 집단에서 유의한 차이를 볼 수 없었다. 또한, DTA를 각각 1 mm, 1.5 mm, 2 mm로 선량분포의 일치성을 비교한 결과 기준필름 3,314개 위치에서 axial필름 평균은 각각 95.04%, 97.56%, 98.13%, sagittal필름 평균은 각각 95.47%, 97.68%, 98.47% 일치하였다. 실험필름과 비교한 결과 3,323개 위치에서 axial필름 평균은 각각 96.38%, 97.57%, 98.04%, sagittal필름 평균은 각각 95.50%, 97.87%, 98.36% 일치하는 것을 확인할 수 있었다. 결 론: 로봇 사이버나이프는 치료 시 환자의 움직임에 의해 발생하는 기준점의 위치변화 오차를 실시간 추적하여 보정하며, targeting 오차를 1 mm 이내, 선량분포는 95% 이상 일치하는 정확성을 확인할 수 있었다.

  • PDF