• Title/Summary/Keyword: Head Distribution

Search Result 915, Processing Time 0.032 seconds

Enhancement of Image Contrast in Linacgram through Image Processing (전산처리를 통한 Linacgram의 화질개선)

  • Suh, Hyun-Suk;Shin, Hyun-Kyo;Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.345-354
    • /
    • 2000
  • Purpose : Conventional radiation therapy Portal images gives low contrast images. The purpose of this study was to enhance image contrast of a linacgram by developing a low-cost image processing method. Materials and Methods : Chest linacgram was obtained by irradiating humanoid Phantom and scanned using Diagnostic-Pro scanner for image processing. Several types of scan method were used in scanning. These include optical density scan, histogram equalized scan, linear histogram based scan, linear histogram independent scan, linear optical density scan, logarithmic scan, and power square root scan. The histogram distribution of the scanned images were plotted and the ranges of the gray scale were compared among various scan types. The scanned images were then transformed to the gray window by pallette fitting method and the contrast of the reprocessed portal images were evaluated for image improvement. Portal images of patients were also taken at various anatomic sites and the images were processed by Gray Scale Expansion (GSE) method. The patient images were analyzed to examine the feasibility of using the GSE technique in clinic. Results :The histogram distribution showed that minimum and maximum gray scale ranges of 3192 and 21940 were obtained when the image was scanned using logarithmic method and square root method, respectively. Out of 256 gray scale, only 7 to 30$\%$ of the steps were used. After expanding the gray scale to full range, contrast of the portal images were improved. Experiment peformed with patient image showed that improved identification of organs were achieved by GSE in portal images of knee joint, head and neck, lung, and pelvis. Conclusion :Phantom study demonstrated that the GSE technique improved image contrast of a linacgram. This indicates that the decrease in image quality resulting from the dual exposure, could be improved by expanding the gray scale. As a result, the improved technique will make it possible to compare the digitally reconstructed radiographs (DRR) and simulation image for evaluating the patient positioning error.

  • PDF

An Analysis on Changing Pattern of Economic Active Population by Working Life Table for Korean Men (우리나라 노동생명표에 의한 노동력추이 분석)

  • 조진만
    • Korea journal of population studies
    • /
    • v.13 no.2
    • /
    • pp.1-18
    • /
    • 1990
  • This is a study which attempt to analyze changing patierns of economic active popu-lation, t o estimato- future patterns, and exa- mine vartons problems arises by changing c ire u mst ances of t he labor force market in- clunging soici al, economic ic, heathl th and demoi-graph ic aspects. We have constructed series of wotking life table which are useful in syt uiolyioig the lirocess of growth and structural change of labor force. Work i ng life tables represent ihie life eyele of econrmic' activity in hi ypothetical cohorts, that is. gen-erat i on of men Sn bject at eat' b period ot f their lives th given ra to's o mor tali it y and of par-- tici pation in economic activities. The tabloes prot' ide measorues of the alvet'age he ng t able of economically aeti \- e life. and agespecific rates of en trannee' into and retirement from the hahn' force. In const routing working life tables, age-specific activity rates and life tabole popula- titoto which represents contemporary condi-tions of moortality in Korea au'e the basic' maltoerials. We have derived the age-specific rates foorm economically active population survey, whoich were conducted by the Bureau of Statistics, Economic Planning Borard of the Korean government. Working life tables are constructed for men wtable these materi- als in the year of 1970, 1980 and 1988 by a modified Wolfbein-Wool's method. Some of the findings may be summerized as follow : 1) A central part of constructing working life table is calculation of stationary' economic active population, which represents the number of men in the stationtary population extoected to be in the labor force at each age group in the life span. The stationary economic active population by age have generally a universal pattern, where they rise sharply in the early twenties, approach its' peak in the thirties decline thereafter. at first graolually and then more rapidly at an advanced age. Korean men show the same general pa ttern of age distribution of stationary eco-- nomic active population with sharp increase hegining from the age interval of 20 to 24, reaching to maximum level at older age. The population. however, presumably, increased substantially due to increaseing school atte endance rates. Another difference exiSts in the youngest age groups, that is the activity rate in the year of 1988 is lower than that of Japan. The table shows an analysis of changes in the age distrihution of labor force between 1970, 1980 and 1988. 2) It was shown an analysis of changes in the age distribution and cause of separation from labor force. The entrance rate to labor force has increased from 18~\5 persons to 299 persons per 1000 head of stationary population between that of 1980 than that of 1988 for Korean men in 20~24 age group. The entrace rate to labor force shows a rapid entrance appearance concentrated on the 15~24 age group. The separation rate from labor force by retirment in Korea in the year of 1988 shows a great difference of the about four times as much as that of Japan. 3) The functions of table illustrate the patterns of working life of males in Korea in 1970, 1980 and 1988. The average remaining number of economically active years, e at age 15 in 1988 is 46.39 which is 2.12 years of increase compared with that of at age 15 in 1970,1980 and 1988 are 43.90,44.27 and 46.39 respectively, showing steadily increase dur- ing the past double decade the increase in the length of economically active life various age may be considered to have come both from extention of general life expectancy and from increasing entrance rate to economic activity in high age that of working is far greater in 1988 than that of 1980. The gaps between expectation of life and average remaining years of economically active widened due to rapid improvement of mortality level in Ko- rea. This observation together with the population pressure by the appearance of a group of younger population implies that constant increase of economically inactive population among older age group.

  • PDF

An Investigation on the self-consciousness Symptoms of the Clerical Workers attendant upon Office Automation (사무 자동화에 따른 사무직 근로자의 건강과 연관된 자각 증상에 대한 조사연구)

  • Jung, Mi Wha
    • Korean Journal of Occupational Health Nursing
    • /
    • v.3
    • /
    • pp.54-70
    • /
    • 1993
  • According as the automation of clerical work(OA ; Office Automation) develops, the use of VDT(Visual or Video Display Terminal) is increasing suddenly. But, in proportion to the spread of office automation(OA tendency), the self-conciousness syptom attendant upon the work is appearing also (Kim, Jung Tae, Lee, Young Ook, 1990). The apparatuses of office enable the clerical workers to be convenient and perform mass businesses. But, they are increasing the opportunity to be exposed to VDT syndrom, techno stress, computer terminal disease, pain by muscle strain(RSI), bradycausia of noise nature, and electromagnetic waves, etc. which are referred to as the new type of occupational diseases to the workers. It is the real situation that the workers to use VDT is complaining of the physical inconvenience sense in the recent newspaper and literature, it is the point of time that the sydrome to come from VDT use and computer terminal disease, etc. must be classified into the occupational disease(Lee, Kwang Young 1990, Lee, Kyoo Hak 1990, Lee, Won Ho 1991, Lee, Si Young 1991, Lee, Joon 1991, Choi, Young Tae 1991, Heo, Seung Ho 1989). In addition, it is the real situation that the scientifitic study result about the scope that electromagnetic waves has influence on the human body has not been suggested yet, and criticism on the stable exposure permission standard about electromagnetic waves to be emitted from VDT and on the problem in the health about electromagnetic waves is continuing. (IEEE Spectrum, 1990). In addition according to the experience of nursery business of industry field, it is the real situation that the patients who consult complaining of physical and mental inconvenience sence, among the users of apparatus of office automation, are reaching 10% of the patients coming to doctor's room. Therefore, it is necessary to confirm the self-consciousness symptom that the clerical workers complain of multilaterally with the actual state examination about the use of the apparatuses of offices automaton. Thus, this study was tried as th basic data for the cosultation and education for the maintenance and furtherance of the health of workers as the nurse of industry field, by confirming the contents of self-consciousness symptom attendant upon the use of the apparatus for office outomation making the financial institution in which the spparatus for office automation in most frequently used as the subject, and by examining whether there is the difference according to the subject of study, the data were collected, by using the questionnaire method, making 200 workers who consented to the study participation as the subject, among the persons who have spent over 3 months since they used the apparatuses for office automation and didn't receive the treatment in hospital due to the clerical disease for recent 3 years. The period of data collection was from Oct. 9, 1991 to Oct. 12. As for the measurement instrument about the complaint if self-consciousness symptom attendant upon the use of apparatuses fo office automation, the question item on the complaint symptom of health problem attendant upon the treatment of VDT that Kim(1991) developed and on CMI health problem and the question items on the fatigue degree due to industry were used by previous examination to 25 persons. Collected data were analyzed with the statistical method such as percentage, arithmetic mean, Person correlation coeffient, Kai square verfication, t-test, ANOVA, etc. by using SPSS/PC+ program, and the result is as follows : 1. The self-consciousness symptom that the clerical workers complained of most frequetly appeared high in 'My eyes are tired'(99.4%), 'I feel fatigue and weariness'(99.4%), 'I feel that my head is heavy5(90.0%), 'eyesight fell'(88.8%), 'I have a stiff neck'(88.8%), 'I fell pain in the shoulder'(85.0%), 'I feel cold and painful in the eyes'(76.9%), 'I feel the dry sense of eyeball'(76.2%), 'My nerves are edgy, and I an fretful, (75.6%), 'I feel pain in the waist'(73.2%) and 'I fell pain in the back'(72.8%). It emerged that the subject use the apparatuses for office automation complained of self-consciousness symptoms related to visual symptoms and musculoskeletal symptoms. 2. As for the general feature of examination subjects, the result to see the distribution by classifying into sex, age, school career, use career of apparatuses for office automation, skillfulness degree of the use of apparatus for office automation, use hours of the apparatuses for office automation per 1 day, type of business of the apparatus for office automation, rest hours during the use of apparatus for office automation, satifaction degree of business of office automation, and work circumstance, etc. emerged as follows : As for the sex of subjects, the distribution showed that men were 58.8% and women were 41.3%, Age was average 26.9. As the distribution of school career, the distribution showed that4below the graduation of high school' was 58.8%, 'graduation from junior college-university' was 35.0%, and 'over graduate school' was 6.3%. In the question to ask the existence or non-existence of experience of health consultation in connection with the work of office automation, the response that I had the consultation exprience and I feel the necessity emergerd as 90.1% And, the case that the subject who didn't wear the glasses or lens before using the OA apparatus wear glasses or lens after using OA apparatus emerged as 28.3% of whole. As for the existence or non-existence of use career of OA apparatus, the case under 3 years was highest as 52. 7%. As for the skillfulnness degree about the use of apparatus for office automation, most of them are skillful with the fact that 'common' was 44.4%, 'skill' was 42.5%, and 'unskillful' was 13.1% As for the use average hours of the apparatus for office automation per 1 day, the distribution showed that the case under 3-6 hours was 33.1%, the case under 6-9 hours was 28.1%, the case under 3 hours was 30.6%, and the case over 9 hours was 8.1% Main OA business and the use hours for 1 day showed in the order of keeping and retrieval, business of information transmission(162min), business of information transmission(79.3 min), business of document framing(55.5 min), and business of duplication and printing(25.4min). as for the rest during the use of apparatus for affice automation, that I take rest occasion demands the major portion, but that I take after completing the work emerged as 33.8%. Though the subiness gets to be convenient by the use of the apparatus for of office automation, respondents who showed the dissatisfaction about the present OA business emergd high as 78.1%. The work circumstances of each office was good with the fact that the temperature of office was 21.8, noise was average 42.7db, and the illumination was average 364.4 lx, in the light of ANSi/HFS 100 Standard. 3. Sight syptom, musculoskeletal symptom, skin and other symptoms showed the significant difference according to the extent of skillfulness of the apparatus for office automation. All the symptoms exept skin symptom showed the difference according to the use hours of the apparatus for office automation. All the question items exept the sytoms of digestive organs and the rest hours during the apparatus for office automation showed the signicant difference. The question item which showed the signicant difference from the satisfaction degree of present OA business showed the significant difference from all the question item classified into 6 groups. But, age and school career didn't significant difference from the complaint of any self-consciousness symptoms.

    . In conclusion, the self-consciousness symptoms of the subjects to use OA apparatus appeared differently, according to sex distiction, skillfull degree of OA apparatus, use hours of OA apparatus, the rest hours during th use of OA apparatus, and the satiafaction degree of persent business. Therefore, it is necessary that the nurse in the inuctry field must recognize to receive the education about the human technological physical condition which is most proper for te use of OA apparatus and about the proper rest method until they get accustomed to the use of OA apparatus. In addition, the simple exercise relax the tention of muscle due to the repetitive simple movement, and the education for the protection of eyesight are necessary.

  • PDF
  • Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

    • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
      • Journal of Radiation Protection and Research
      • /
      • v.27 no.1
      • /
      • pp.1-10
      • /
      • 2002
    • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

    A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

    • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
      • Journal of radiological science and technology
      • /
      • v.26 no.2
      • /
      • pp.37-42
      • /
      • 2003
    • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

    • PDF

    Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

    • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
      • Progress in Medical Physics
      • /
      • v.23 no.1
      • /
      • pp.15-25
      • /
      • 2012
    • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.

    Dosimetric and clinical review on the application of TOMO_edge mode (토모테라피 Edge 모드를 이용한 임상적 유용성 고찰)

    • Kim, Lizzy
      • The Journal of Korean Society for Radiation Therapy
      • /
      • v.26 no.2
      • /
      • pp.177-182
      • /
      • 2014
    • Purpose : The goal of this study was to compare and analysis the dose distribution and treatment time between Tomotherapy planning with fixed jaw(FJ) and dynamic jaw(DJ). Materials and Methods : Seven patients were selected in the study including five common clinical cases(brain, head and neck(HN), lung, prostate, spine). 1) Helical Tomotherapy plans with FJ and DJ were generated with the same planning parameters such as Modulation factor, Pitch and Field width. 2) Tomo_edge plans with a larger field width were generated to compare to conventional HT delivery with fixed jaw. Dosimetric evaluation indices for target coverage are Dmin, Conformity index(CI) and for whole body including target are $V_{10%}$, $V_{25%}$, $V_{50%}$, $V_{75%}$ using Dose-volume histogram(DVH). Also, Treatment time and Cumulative MU were used for clinical review on Tomo_edge. Results : In case of using the same field width of Tomotherapy planning with FJ and DJ, the averaged variations were $V_{10%}$: -11.91%, $V_{25%}$: -7.6%, $V_{50%}$ :-4.75%, $V_{75%}$: -1.04%. Tomo_edge with a larger field width provides the averaged variations for target coverage: Dmin: -0.72%, CI: -1.25% and also shows the tendency of a sharp $V_{x%}$ decline in low dose area. The clinical improvements in the larger field width with DJ were observed in the treatment time, ranging from -51.21% to -15.11, and the Cumulative MU decrease, ranging from -57.74% to -15.31%. Conclusion : Target coverage achieved by FJ and DJ with the same field width has little differences. But integral doses on whole body efficiently decreased. Compared to the conventional HT delivery, Tomo_edge with a larger field width presents a little worse target coverage. However, it provides faster treatment delivery and improved cranial-caudal target dose conformity. Therefore, Tomo_edge mode is efficient in improving the treatment time and integral dose while maintaining comparable plan quality in clinic.

    A STUDY OF THE NORMAL & ABNORMAL OCCULSAL PATERNS IN ADULTS USING THE SUPERIMPOSED RUBBER PATTERN METHOD (Superimposed Rubber Pattern법에 의한 성인 정상 및 비정상 교합자의 교합 양상에 관한 연구)

    • Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Young-Hyuk;Choi, Boo-Byung
      • The Journal of Korean Academy of Prosthodontics
      • /
      • v.33 no.3
      • /
      • pp.467-491
      • /
      • 1995
    • In order to analyze the occlusin of intercuspation with maximun bite force, fifteen healthy adult subjects with the ages 23 to 27 were studied(Group1 ; 5-normal occlusion with Angle's Class1, Group2 ; 5-Angle's Class2 malocclusion, Group3 ; 5-Angle’s Class3 malocclusion). Head Position was fixed with occlusal plane paralleling to horizontal line and occlusal registration r cord was made with polyether rubber impression material(Ramitec, ESPECo. West Germany). After all subject were trained for maximum intercuspation at least 5 times, occlusal registration procedure was repeated for this study. Lower posterior rubber occlusal registration records were sliced with 1mm thickness using precision metal sliding channel(Hitachi Ind. Co., Japan). Gross sectional drawings were traced from occluding view of upper and lower posterior teeth on the rubber slices using digitizer, and superimposed for the determination of each drawing distance(Superimposed Rubber Pattern Method). Based on superimposed rubber pattern drawings, total area of occlusal view, sum of each area of the 5 divided occlusal contact provinces and its ratio, total area and number of occlusal contact area were determined to elucidate occlusal stability in the normal and abnormal occlusion groups. The data were analysed by t-test(p=0.05) to determine statistical significance. The obtained results were as follows : 1. Group1 showed the largest standard area with occlusal view of the lower posterior teeth and Group3 showed the smallest area. There was a significant difference between Group2 and Group3(p=0.025), and Gropu1 was not statistically different for both Group2 and Group3. 2. Means and ratio of the under 2.0mm area(D) and ratio showed $197.49mm^2$, 59.76% in Group1, $188,69mm^2$, 56.10% in Group2, and $174.23mm^2$, 55.76% in Group3. The results that Group1 has the most area/ratio and Group3 has the least area/ratio can be considered Group1 is the most advantageous for masticatory effective area, and Group3 is the least adnantageous. 3. Means and ratio of the under 1.0mm area(C) were $198.96mm^2$, 42.65% in Group1, 123.06$mm^2$, 46.58% in Group2, and $92.24mm^2$, 29.52% in Group3. These data means that Group1 is the most advantageous in terms of masticatory effective area and Group3 is the least. 4. Means and ratio of the under 0.5mm area(B) were $86.68mm^2$, 26.68% in Group1, $62.98mm^2$, 18.71% in Group2, and $36.44mm^2$, 11.66% in Group3. These can also be considered Group1 is the most advantageous for masticatory effective area and occlusal stability. 5. Means and ratio of the under 0.05mm area(A) were $30.92mm^2$, 9.21% in Group1, $14.31mm^2$, 4.25% in Group2, and $7.59mm^2$, 2.43% in Group3. The area ratio of the each subject group was(4.1) : (1.9) : (1)and the data of the under 0.05mm area has the intimate relationship with inter-group and intra-group data/ratio. 6. First molar showed the most occlusal contact points in all subject group and Group1 showed somewhat uniformly distributed occlusal contact point except first premolar. In Group2, all contact point in posterior teeth showed significantly reduced distribution except first molar. Group3 showed evenly distributed contace points in first and second molars.

    • PDF

    A Study on Estimation of Caring Demand for Extended Care Facilities by Activities of Daily Living (ADL(Activities of Daily Living)을 이용한 무료노인요양시설 수용노인의 돌봄필요도에 관한 연구)

    • Kim, Chul-Woung;Moon, Ok-Ryun;Lee, Sang-Yi;Yoo, Jae-Won;Yi, Sang-Gu
      • Journal of Preventive Medicine and Public Health
      • /
      • v.31 no.3 s.62
      • /
      • pp.564-578
      • /
      • 1998
    • Most extended care facilities have admitted both the healthy and unhealthy elderly, among which members' average caring demand vary. The Aged Welfare Law, however, currently provides no reasonable basis on the staffing policy for extended care facilities. It just reflects the admitted number of the elderly rather than differences in members' average caring demand among facilities. This study is designed to estimate the need for caring staff on the basis of the correlation between the individual health status measured by various tools including Activities of Daily Living and caring demand by actual service time for each one. The sample included all of the admitted elderly(187 persons) in 4 extended care facilities, two in Seoul and the other two in Kangwon-Do over the survey period October 5 through October 20, 1996. The survey process consisted of 3 stages. (1) The current staffing information was collected through self-completed written questionnaires left for head of official in each facility. (2) Six graduate students at School of Public Health interviewed all residents to collect information on their health status and sociodemographics. The response rate for the interview was relatively high(85%). (3) Information on direct and indirect caring time consumed for each residents came from self-completed written questionnaires given to nurses and helpers in each target facilities. Analysis of the data was made using Pearson's correlation and multiple regression technique through SAS program. Based on this procedure, the following was found. 1. No facility meet the staffing standard in the Aged Welfare Law completely. 2. It is actual service time that is most correlated with ADL(Activities of daily living). 3. When all of the elderly are divided by four groups based on the level of ADL, the mean values of needed caring time in each group are 15, 21, 36 and 88 minutes respectively. 4. There is no significant difference among facilities in distribution of elderly person by group. 5. No facility meets the estimated number of nurses and helpers which reflects health status of the admitted elderly. Therefore, it is required that severity of the admitted elderly be considered in establishing staffing standard for extended care facility.

    • PDF

    Investigation of Habitat and Development of Indoor-rearing Condition of Peacock Butterfly, Inachis io(Linnaeus) (공작나비(Peacock butterfly), Inachis io (Linnaeus)의 서식지 조사 및 실내사육 조건 구명)

    • Lee, Sang-Hyun;Kim, Se-Gwon;Nam, Gyoung-Pil;Son, Jai-Duk;Kim, Nam-ee;Park, Young-Kyu;Kang, Pil-Don;Choi, Young-Cheol
      • Journal of Sericultural and Entomological Science
      • /
      • v.51 no.1
      • /
      • pp.1-8
      • /
      • 2013
    • This study was conducted for investigation of habitat and development of indoor-rearing conditions of peacock butterfly, Inachis io (Linnaeus). Three different region, Mt. Kwangduk-san, Mt. Hae-san and Mt. Taebaek-san in Kangwon-do, was selected for investigation of domestic distribution and ecological environment of peacock butterfly. In result, there are many butterflies in the only two region, Mt. Kwangduk-san and Mt. Hae-san. On 16th April, 4 overwintered butterflies were observed in Mt. Hae-san. At the end of June and early in July, 51 individual next generation's butterflies were observed in Mt. Kwangduk-san and Mt. Hae-san. For development of indoor-rearing conditions, collected each 15 male and female peacock butterflies was reared in a room condition. Female butterflies laid eggs in the egg cluster on the underside of host-plant's leaves, Urtica angustifolia Fisch., in the ovipositioning room. We took 11 egg cluster with average $404.6{\pm}23.6$ eggs. Hatchablity of eggs was 92.3%, and the eggs hatched within $5.1{\pm}0.9$ days from the day of oviposition under high temperature, long day condition($25^{\circ}C$, 14L:10D). The larval period was $18.3{\pm}1.0$ days under high temperature, long day condition($25^{\circ}C$, 14L:10D), showing 81.0% pupal ratio. The head width of each developmental larval stage were $0.37{\pm}0.01mm$(1st instar), $0.66{\pm}0.02mm$(2nd instar), $1.07{\pm}0.05mm$(3rd instar), $1.81{\pm}0.07$(4th instar), $2.76{\pm}0.08$(5th instar). The pupal period was $8.4{\pm}0.6$ days, and the emergence rate was 87.5%.


    (34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
    Copyright (C) KISTI. All Rights Reserved.