• Title/Summary/Keyword: Hazardous area

Search Result 394, Processing Time 0.022 seconds

A Study on Indoor Environment Safety Level Certification of Educational Facilities and School Safety Level Evaluation (교육시설 안전 등급 인증과 학교 안전도 심사에 대한 연구)

  • Myoung-Kwan Kim;Young-Guk Kwon
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.2
    • /
    • pp.17-28
    • /
    • 2023
  • This study aimed to verify the validity of the evaluation items and weight determination of the indoor environmental safety area, which has the most frequent accidents, among the safety certification evaluations of educational facilities by the Ministry of Education of the Republic of Korea, which has been conducted since May 2021. As a preceding study, the evaluation items of the school safety evaluation checklist being implemented in the US state of Vermont were compared, and the causes of accidents judged by teachers in the accident experiences written by 200 Korean teachers were compared with the safety certification evaluation items belonged to the Ministry of Education. In addition, research literature using the AHP analysis technique on safety risks of elementary and secondary schools in China and safety evaluation index study cases of 539 elementary school children in Indonesia were analyzed. Through these preceding studies, measures to add and adjust evaluation items were derived and the validity and importance rankings of evaluation items were calculated through AHP questionnaires to teachers and safety experts. In addition, a survey was conducted on 104 ordinary people to verify the results of expert analysis. As a result of expert AHP analysis, 'safety education and disaster response training (.396)' was the highest priority for the relative importance of the first layer, followed by 'safety measures (.387)' and 'building materials'. Safety (.216)' was found to be the highest priority. In the overall importance ranking of the 13 second-tier screening items, safety accident prevention education had the highest priority and disaster preparedness training ranked second, proving that the Ministry of Education's review weight was underestimated. In addition, slip and collision accident countermeasures, which were not in the existing Ministry of Education review items, ranked 4th, laboratory practice room safety measures ranked 6th, and sanitation, cleanliness, hazardous substance management, and cafeteria/cooking room safety measures ranked 9th, indicating a significant level of importance. Referring to the importance ranking, which is the result of this study, it is suggested that it is necessary to review the weight of each review item again.

Analysis of Non-Biodegradable Organic Matter Leakage Characteristics and Correlation Analysis in Paldang Lake and its Upper Reaches (팔당호와 팔당호 상류의 난분해성 유기물질 유출 특성 분석 및 상관성 분석)

  • Chaewon Kang;Kyungik Gil
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.221-229
    • /
    • 2023
  • Extracted from the metropolitan area, the Paldang Lake, which supplies approximately 8 million tons of water, has achieved a BOD (Biochemical Oxygen Demand) of 1.1 mg/L as a result of water quality preservation policies. However, concerning the COD (Chemical Oxygen Demand) component that encompasses refractory organic matter, there has been an observable upward trend in concentration. The introduction of refractory organic matter into the water source of Paldang Lake brings potential increments in BOD, generates off-putting tastes and odors in tap water, increases THM (Trihalomethane) formation, and triggers algae proliferation. Moreover, if residual hazardous refractory pollutants persist in aquatic environments, they may induce endocrine disruption and phenomena such as antibiotic resistance. In this study, a monitoring campaign was executed to discern the concentration of refractory organic matter emissions from point and non-point sources within Paldang Lake and its upstream region, with the aim of managing refractory organic matter in Paldang Lake. By comparing refractory organic matter emission concentrations across monitored areas, the elimination efficiency at wastewater treatment plants was assessed. Additionally, employing the Pearson correlation correlation analysis technique, correlations among refractory organic matter indices, antecedent wet days, and antecedent dry days were explored. The concentrations of refractory organic matter in rivers and Paldang Lake exhibited a similar pattern. Wastewater treatment plant effluents exhibited higher concentrations compared to rivers and Paldang Lake. The assessment of refractory organic matter removal at wastewater treatment plants indicated a removal efficiency of 65.73%. However, no significant correlation emerged between refractory organic matter emission concentration and antecedent wet days or priory antecedent dry days. This absence of correlation is attributed to data scarcity, underscoring the need for long-term monitoring and data accumulation.

Health Assessment for Glass Fibre Landfill at Gozan-dong, Inchon (인천시 고잔동에서 제기된 유리섬유에 의한 건강피해 역학 조사)

  • Cho, Soo-Hun;Ju, Yeong-Su;Kim, Kyung-Ryul;Lee, Kang-Kun;Hong, Kug-Sun;Eun, Hee-Chul;Song, Dong-Bin;Hong, Jae-Woong;Kwon, Ho-Jang;Ha, Mi-Na;Han, Sang-Hwan;Seong, Joo-Heon;Kang, Jong-Won
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.77-101
    • /
    • 1997
  • In September 1994, residents of Gozan-dong, Incheon City, made a petition to the government about their health problems which might be caused by previous glass fibre landfill nearby 'H' company. In february 1995, at regular academic meeting of occupational and environmental medicine, a research team of 'D' University presented that they had found glass fibres in groundwater of the area through their survey. They were suspicious of probable association between ingestion of groundwater contaminated with glass fibres and skin tumors among residents. A joint research team was formed and carried out the survey of environment concerning groundwater and its glass fibre existence, and health assessment of residents in the area and industrial workers of 'H' company during May to November, 1995. Analysis of groundwater flow system indicates that the flow lines from the glass fibre landfill pass through or terminate at the 6 houses around the landfill. This means that the groundwater of the 6 houses around the glass fibre landfill could be affected by some possible contaminants from the landfill, but the groundwater quality of the other houses was irrelevant to the landfill. The qualitative and qualitative analyses for glass fibres in 54 groundwater samples including those from the nearby 6 houses, were carried out using SEM equipped with EDS, resulting in no evidence for the presence of glass fibres in the waters. Major precipitates, formed in waters while boiling, were identified as calcium carbonates, in particulary, aragonites in needle form. The results of health assessments of 889 residents in Gozan-dong, participated in this study, showed statistically significant differences in past medical histories of skin tumor and respiratory disease between the exposed group (31 persons who inhabited in 6 houses around the landfill) and the control group, but no significant differences in past medical histories of other diseases, such as cancer mortality, current gastroscopic findings, current skin diseases and respiratory diseases, etc. Also, we could not prove any glass fibres in excised specimens of 9 skin tumors in both groups and there were no health problems possibly associated with glass fibres in employees of the 'H' company. After all, we could not authenticate the association, raised by prior investigators, between groundwater streams, assumedly contaminated with glass fibres or not, and specific disease morbidities or common disease/symptom prevalences. That is, we could not find any glass fibres in groundwater as the only exposure factor of this study hypothesis, and there were not enough certain evidences such as increasing disease prevalences, for examples, skin, respiratory and gastrointestinal diseases etc, possibly related to glass fibre exposure, in exposed group. As a matter of course, the conditions for confirming causal association, for example, strength of the association, consistency of the association, specificity of the association, temporality of the association and dose-response relationship etc, have not been satisfied. In conclusion, we were not able to certify the hypothesis that contamination of groundwater with glass fibres might cause any hazardous health effects in residents who used it for drinking.

  • PDF

Adsorption Characteristics of Oxyanions on Ferrihydrite and Mineral Phase Transformation (페리하이드라이트의 산화음이온 흡착 특성과 광물상 변화)

  • Gyure Kim;Yeongkyoo Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.3
    • /
    • pp.301-310
    • /
    • 2023
  • Ferrihydrite is an iron oxide mineral that is easily found in the natural environment, including acid mine drainage, and has a low crystallinity and high specific surface area, resulting in high reactivity with other ions, and can remove environmentally hazardous substances. However, because ferrihydrite is a metastable mineral, there is a possibility of releasing adsorbed ions by phase transformation to other minerals having low surface area and high crystallinity. In this study, the adsorption characteristics of arsenate, chromate, and selenate on ferrihydrite and the oxyanion removal efficiency of ferrihydrite were studied considering mineral phase transformation. At both pH 4 and 8, the adsorption of oxyanions used in the study were in good agreement with both Langmuir and Freundlich adsorption models except for selenate at pH 8. Due to the difference in surface charge according to pH, at pH 4 a higher amount of ions were adsorbed than at pH 8. The adsorption amount were in the order of arsenate, chromate, and selenate. These different adsorption models and adsorption amounts were due to different adsorption mechanisms for each oxyanions on the surface of ferrihydrite. These adsorption characteristics were closely related to changes in the mineral phase. At pH 4, a phase transformation to goethite or hematite was observed, but only a phase transformation to hematite was observed at pH 8. Among the oxyanion species on ferrihydrite, arsenate showed the highest adsorption capacity and hardly caused phase transformation during the experimental period after adsorption. Contrary to this, chromate and selenate showed faster mineral phase transformation than arsenate, and selenate had the lowest retardation effect among the three oxyanions. Ferrihydrite can effectively remove arsenate due to its high adsorption capacity and low phase transformation rate. However, the removal efficiency for other two oxyanions were low by the low adsorption amount and additional mineral phase transformation. For chromate, the efficient removal is expected only at low concentrations in low pH environments.

Comparative Analysis on the Perceptions for Food Additives Between Elementary School Teachers and Nutrition Teachers (식품첨가물에 대한 초등교사와 영양교사의 인식 비교)

  • Kim, Jeong-Weon;Lee, Eun-Ju
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.2
    • /
    • pp.74-84
    • /
    • 2016
  • Literacy on food additives of elementary school teachers (ET) and nutrition teachers (NT) could be influential factor on safe dietary education for school children. Therefore, the perceptions and information needs on food additives were surveyed from 351 elementary school teachers and nutrition teachers in metropolitan area of Korea, and the basic data for the promotion of risk communication on food additives among them were obtained. Compared to ET who consider 'taste' (39.1%) as the most important factor while purchasing food, NT considered 'safety' (68.1%) first (p < 0.001). Among the food labelling items, the level of understanding on food additives was the lowest both in ET (3.53) and NT (4.17), and NT showed better levels of understanding overall on food labels. Both ET and NT regarded hazardous factors of food as environmental pollutants, foodborne pathogens, and food additives in order, and tended to select 'no additives' or 'no artificial color' products while purchasing processed food. Although NT answered that they know all food additives had been passed the evaluation of safety and effectiveness tests (100%) and have standards of use (81.9%), majority of them (87.5%) believed the consumption of food additives are harmful on human health. ET (75.2%) also regarded food additives as dangerous materials. Above results suggested the necessity of proper and enough risk communication for both ET and NT. Both ET and NT wanted to have information on the safety or hazard of food additives. Most preferred media to get the information on food additives was TV (3.80) among ET and lecture (3.65) among NT. ET and NT trusted hospital, research institution/universities or the personnels working in these institutions as the provider of information on food additives. The result that the trust levels of ET and NT on government were relative low suggested the weakness of risk communication in Korean government. Although ET and NT answered that they do not trust mass media, their behaviors were affected by them such as reading food labels in ET (39.4%) and reducing the consumption of food additives in NT (50%). They also indicated mass media's problem of sensitive approach on food additives and asked the urgent reaction of government by providing sound information through experts on food additives. Above results revealed that ET and NT have different perceptions and information needs on food additives, therefore, proper risk communication should be provided for them to serve as dietary educators for elementary school children.

Precipitation of $CaCO_3$ Crystals from Variously Supersaturated Solutions (다양한 과포화 조건하에서의 탄산염광물의 합성에 대한 연구)

  • Hyeon Yoon;Kim, Soo-Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.11-21
    • /
    • 2004
  • Crystallization of CaC $O_3$ from the solutions of various degrees of supersaturation was carried out by a spontaneous precipitation method. The solution was kept at $25^{\circ}C$ and pH 6.9∼8.8. The solution compositions were varied in two ways: (1) The total carbonate, [C $O_3$]$_{Τ}$, to total calcium. [Ca]$_{Τ}$, ratios vary as ; [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ >1. [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$=1, and [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$<1. (2) The total calcium concentration, [Ca]$_{Τ}$, held at 0.02 mo1/d $m^3$, 0.2 mo1/d $m^3$, and 0.4 mo1/d $m^3$. We found that the CaC $O_3$ phase crystallized from the solutions of [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ $\geq$ 1 was mostly calcite with less than 1% of vaterite, while the CaC $O_3$ crystals precipitated from low carbonate concentration toward calcium concentration, [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ < 1, were dominated by vaterite crystals. It appears that the polymorph of CaC $O_3$ precipitate was mainly controlled not by the calcium concentration but by the carbonate concentration during the spontaneous precipitation. Also, we found that the surface roughness of vaterite increased with decreasing carbonate concentration from 0.8 or 0.5 of [C $O_3$]$_{Τ}$/[Ca]$_{Τ}$ ratios and the surface area of vaterite increased from 5.64∼7.34 $\mu\textrm{m}$ to 8.39∼10.3 $\mu\textrm{m}$.

Effect of Noise in Human Body (소음이 인체에 미치는 영향)

  • 이영노
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.7-8
    • /
    • 1972
  • The effects of noise exposure are of two types: Nonauditory effects and auditory effects. Nonauditory effects of noise exposure are interference with communication by speech, sleeping and emotional behavior. The noise will cause the high blood pressure and rapid pulse, also that decrease the salivation and gastric juice. in experimentaly showed that the Corticoid hormon: Gonatotropic hormone were decrease and Thyrotropic hormoone is increase. Auditory effect of noise exposure. when the normal ear is exposed to noise at noise at hamful intensities (above 90㏈) for sufficiently long periods of time, a temoral depression of hearing results, disappearing after minutes or hours of rest. When the exposure longer or intesity greater is reached the Permanent threshold shift called noise-induced hearing loss. Hearing loss resulting from noise exposure presents legal as well as medical problems. The otologist who examines and evaluates the industrial hearing loss cases must be properly informed, not only concerning the otologic but also about the physical and legal aspects of the problems. The measurement of hearing ability is the most important part of a hearing conservation, both preplacement and periodic follow-up tests of hearing. The ideal hearing conservation program would be able to reduce or eliminate the hazardous noise at its source or by acoustic isolation of noisy working area and two ear protections (plugs and muff type) were developed for personal protection.

  • PDF

Key Methodologies to Effective Site-specific Accessment in Contaminated Soils : A Review (오염토양의 효과적 현장조사에 대한 주요 방법론의 검토)

  • Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.383-397
    • /
    • 1999
  • For sites to be investigated, the results of such an investigation can be used in determining foals for cleanup, quantifying risks, determining acceptable and unacceptable risk, and developing cleanup plans t hat do not cause unnecessary delays in the redevelopment and reuse of the property. To do this, it is essential that an appropriately detailed study of the site be performed to identify the cause, nature, and extent of contamination and the possible threats to the environment or to any people living or working nearby through the analysis of samples of soil and soil gas, groundwater, surface water, and sediment. The migration pathways of contaminants also are examined during this phase. Key aspects of cost-effective site assessment to help standardize and accelerate the evaluation of contaminated soils at sites are to provide a simple step-by-step methodology for environmental science/engineering professionals to calculate risk-based, site-specific soil levels for contaminants in soil. Its use may significantly reduce the time it takes to complete soil investigations and cleanup actions at some sites, as well as improve the consistency of these actions across the nation. To achieve the effective site assessment, it requires the criteria for choosing the type of standard and setting the magnitude of the standard come from different sources, depending on many factors including the nature of the contamination. A general scheme for site-specific assessment consists of sequential Phase I, II, and III, which is defined by workplan and soil screening levels. Phase I are conducted to identify and confirm a site's recognized environmental conditions resulting from past actions. If a Phase 1 identifies potential hazardous substances, a Phase II is usually conducted to confirm the absence, or presence and extent, of contamination. Phase II involve the collection and analysis of samples. And Phase III is to remediate the contaminated soils determined by Phase I and Phase II. However, important factors in determining whether a assessment standard is site-specific and suitable are (1) the spatial extent of the sampling and the size of the sample area; (2) the number of samples taken: (3) the strategy of taking samples: and (4) the way the data are analyzed. Although selected methods are recommended, application of quantitative methods is directed by users having prior training or experience for the dynamic site investigation process.

  • PDF

A Study on the Consciousness Survey of Improvement of Emergency Rescue Training -Based on the Fire Fighting Organizations in Gangwon Province- (긴급구조훈련 개선에 관한 의식조사 연구 -강원도 소방조직을 중심으로-)

  • Choi, Yunjung;Koo, Wonhoi;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.440-449
    • /
    • 2019
  • Purpose: Fire-fighting organizations are the very first agencies that take actions at a disaster scene, and emergency rescue training is carried out for prompt and systematic response. However, there is a need for a change due to the limitations in emergency rescue trainings such as perfunctory trainings or trainings without considering regional or environmental characteristics. Method: This study is to conduct theoretical review with regard to emergency rescue training and present a measure to improve the emergency rescue training through attitude survey targeting fire-fighting organizations in Gangwon area. Result: Facilities that cause difficulties when doing emergency rescue activity were mostly hazardous material storage and processing facilities. In terms of the level of emergency rescue and response task, most respondents answered that the emergency rescue was insufficient. The respondents answered that the effectiveness of emergency rescue training was helpful, but some responses showed that the training was not helpful because of scenario-based training, seeming training, similar training carried out every year, unrealistic training, and lack of competent authorities' interest and perfunctory participations. Most respondents answered for the appropriateness of emergency rescue training and evaluation that they were satisfied, however, they were not satisfied with the evaluation methods irrelevant to the type of training, evaluation methods requiring unnecessary training scale, and evaluation methods leading perfunctory participations of competent authorities. Lastly, respondents mostly answered that training reflecting various damage situations are necessary regarding the demand on the improvement of emergency rescue training. Conclusion: The improvement measures for emergency rescue training are as follows. First, it is necessary to set and prepare various training contents in accordance with regional characteristics by reviewing major disasters occurred in the region. Second, it is necessary to revise the emergency rescue training guidelines and manuals for appropriate training plan for each fire station, provide education and training for working-level staff members, and establish training in a way that types, tactics, and strategies of emergency rescue training could be utilized practically. Third, it is necessary to prepare a scheme that can lead participation and provide incentive or penalty from the planning stage of training in order to increase the participation of supporting and competent authorities when an actual disaster occurs. Fourth, it is necessary to establish support arrangements and cooperative systems by authority through training by fire stations or zones in preparation for disaster situations that may occur simultaneously. Fifth, it is necessary to put emphasis on the training process rather than the result for emergency rescue training and evaluation, pay attention to the identification of supplement points for each disaster situation and make improvements. Especially, type or form of training should be considered rather than evaluating the execution status of detailed processes, and the evaluation measure that can consider the completeness (proficiency) of training and the status of role performance rather than the scale of training should be prepared. Sixth, type and method of training should be improved in accordance with the characteristics of each fire station by identifying the demand of working-level staff members for an efficient emergency rescue training.