• Title/Summary/Keyword: Harris hip score

Search Result 30, Processing Time 0.034 seconds

Hip Arthroplasty Using the Bencox® Hip System: An Evaluation of a Consecutive Series of One Thousand Cases

  • Lee, Joong-Myung;Sim, Young-Suk;Choi, Dae-Sung
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.210-218
    • /
    • 2018
  • Purpose: This is a report on the outcomes associated with a consecutive series of 1,000 cementless hip arthroplasties utilizing the $Bencox^{(R)}$ hip stem-the first Korean-developed hip prosthesis. Materials and Methods: A consecutive series of 1,000 hip arthroplasties using the $Bencox^{(R)}$ hip stem were analyzed, starting from its initial release (September 2006) until June 2014. Patients in this consecutive series underwent surgery for fractures (n=552), arthritis (n=155), avascular necrosis (n=209), and revisions (n=84). Of these 1,000 cases, patients with a minimum follow-up of at least 1 year (n=616) were retrospectively analyzed for radiographic and clinical outcomes (i.e., Harris hip score). The stability of the prosthesis was evaluated by examining subsidence. Results: During the follow-up period (mean follow-up period of 54.8 months), there were 2 cases requiring revision of the femoral stem-both were caused by periprosthetic fractures and neither involved stem loosening. The mean Harris hip score during follow-up was 95.5. Bone ongrowth occurred in 95% of patients; no cases of subsidence or aseptic loosening of the stem were detected, and no cases of postoperative complications such as ceramic breakage were observed. Conclusion: Clinical and radiographic evaluations of hip arthroplasty using the $Bencox^{(R)}$ hip stem revealed excellent outcomes with an average of 54.8 month follow-up in a consecutive series of 1,000 cases.

Three Case Reports of Avascular Necrosis of Femur Head Have Treated by Acupotomy (침도요법을 통한 대퇴골두 무혈성 괴사환자 3명에 대한 증례보고)

  • Kim, Sung-Soo;Park, Se-Woon;Moon, Hyo;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.28 no.5
    • /
    • pp.143-151
    • /
    • 2011
  • Objectives : The purpose of this study is to report the effect of acupotomy for patient with avascular necrosis(AVN) of femur head. Methods : Three patient who had been diagnosed as AVN participated in this study. The patient treated by acupotomy therapy. After the treatment, the patient was measured by visual analogue scale(VAS), Harris hip score and five likert scale Results : The patient informed the researcher of reduced pain and improved range of movement after the conduct of acupotomy therapy. The efficacy of acupotomy treatment was reaffirmed by the results of the VAS, physical examination (ROM, Patrcik sign), Harris hip score. Conclusions : Acupotomy therapy on AVN of femur head shows the efficacy in reducing pain and improving movement.

Hip Resurfacing Arthroplasty after Failure of Tantalum Rod Insertion in Patients with Osteonecrosis of the Femoral Head

  • Yoon Je Cho;Kee Hyung Rhyu;Young Soo Chun;Hyun Gon Gwak
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.219-226
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the clinical outcomes and efficacy of hip resurfacing arthroplasty (HRA) in patients with osteonecrosis of the femoral head after the failure of porous tantalum rod insertion without rod removal. Materials and Methods: Conversion to hip resurfacing arthroplasty was performed in 10 patients (11 hips) with a mean period of 14.9 months after the primary surgery. The mean follow-up period was 73.7 months. Analysis of pre and postoperative range of motion (ROM), University of California at Los Angeles (UCLA) activity score, modified Harris hip score, and visual analog scale (VAS) pain score was performed. Radiographic analysis of component loosening and osteolysis was performed. Results: The postoperative ROM showed significant improvement (P<0.05), excluding flexion contracture. The modified Harris hip score showed improvement from 65.82 to 96.18, the UCLA score showed improvement from 4.18 to 8.00, and the VAS pain score was reduced from 6.09 to 1.80. All scores showed statistically significant improvement (P<0.05). No component loosening or osteolysis was detected by radiographic analysis. Conclusion: Satisfactory results were obtained from conversion hip resurfacing arthroplasty after failure of porous tantalum rod insertion without rod removal. The findings of this study demonstrate the advantages of HRA, including no risk of trochanteric fracture and no bone loss around the tantalum rod. In addition, the remaining porous tantalum rod provided mechanical support, which reduced the potential risk of femoral neck fracture or loosening. This technique can be regarded as a favorable treatment option.

A Rehabilitation for Total Hip Replacement in Korean Medicine: A Report of Three Cases (고관절 전치환술 후 한방 재활치료에 대한 증례 보고)

  • Ha, Won-Bae;Lee, Jong-Ha;Ko, Youn-Seok;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.26 no.3
    • /
    • pp.153-164
    • /
    • 2016
  • The objective of this study was to propose a rehabilitation protocol for total hip replacement in Korean medicine and to report its effectiveness. Three patients who had undergone total hip replacement were treated using the rehabilitation protocol in Korean medicine. We evaluated the outcome evaluating physical examination findings of the hip joint, numeric rating scale, pain disability index, Harris hip score, and walking state. After the treatment, we observed that hip movement and muscular strength improved. Moreover numeric rating scale, pain disability index, Harris hip score, and walking state of patients improved. A rehabilitation in Korean medicine can be effectively used for total hip replacement patients. The limitation of this study was the insufficient number of cases. Further studies are needed to design a rehabilitation protocol in Korean medicine.

Effects of Chuna Manual Therapy after Hip Arthroplasty: A Systematic Review and Meta-Analysis of Randomized Controlled Trials (고관절 치환술 후 추나치료 효과: 체계적 문헌고찰 및 메타분석)

  • Lee, Eun-Byeol;Kim, Hyeon-Ji;Kim, Chae-Young;Ahn, Hee-Duk
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.32 no.2
    • /
    • pp.95-103
    • /
    • 2022
  • Objectives This study was conducted to assess the effect of chuna manual therapy after hip arthroplasty. Methods We searched across 9 electronic databases (PubMed, Cochrane Library, Wangfang data, China National Knowledge Infrastructure [CNKI], Oriental Medicine Advanced Searching Integrated System [OASIS], National Digital Science Library [NDSL], Korean Medical Database [KMBASE], Koreanstudies Information Service System [KISS], Research Information Sharing Service [RISS]) to find randomized controlled clinical trials for chuna manual therapy after hip arthroplasty. Results On inclusion criteria, 11 appropriate studies were included and analyzed. The deep vein thrombosis incidence of the chuna manual therapy group was statistically lower than the conventional treatment group (p=0.0002). Chuna manual therapy significantly improved the Harris hip score compared with conventional treatment (p<0.00001). Also, chuna manual therapy combined with herbal fumigation therapy significantly elevated the hip joint function score of Harris hip score compared with the conventional therapy group (p<0.00001). Conclusions The systematic review showed that chuna manual therapy had significant effects on hip arthroplasty. Nonetheless, considering the high risk of bias and geographic bias, further research with well-designed studies is required to support the effectiveness of chuna manual therapy.

Primary Arthroplasty for Unstable and Failed Intertrochanteric Fractures: Role of Multi-Planar Trochanteric Wiring Technique

  • Javahir A. Pachore;Vikram Indrajit Shah;Sachin Upadhyay;Shrikunj Babulal Patel
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.108-121
    • /
    • 2023
  • Purpose: The primary objective of the current study is to demonstrate the trochanteric wiring technique. A secondary objective is to evaluate the clinico-radiological outcomes of use of the wiring technique during primary arthroplasty for treatment of unstable and failed intertrochanteric fractures. Materials and Methods: A prospective study including follow-up of 127 patients with unstable and failed intertrochanteric fractures who underwent primary hip arthroplasty using novel multi-planar trochanteric wiring was conducted. The average follow-up period was 17.8±4.7 months. Clinical assessment was performed using the Harris hip score (HHS). Radiographic evaluation was performed for assessment of union of the trochanter and any mechanical failure. P<0.05 was considered statistically significant. Results: At the latest follow-up, the mean HHS showed significant improvement from 79.9±1.8 (at three months) to 91.6±5.1 (P<0.05). In addition, no significant difference in the HHS was observed between male and female patients (P=0.29) and between fresh and failed intertrochanteric fractures (P=0.08). Union was achieved in all cases of fractured trochanter, except one. Wire breakage was observed in three patients. There were five cases of limb length discrepancy, three cases of lurch, and three cases of wire-related bursitis. There were no cases of dislocation or infection. Radiographs showed stable prosthesis in situ with no evidence of subsidence. Conclusion: Use of the proposed wiring technique was helpful in restoring the abductor level arm and multi-planar stability, which enabled better rehabilitation and resulted in excellent clinical and radiological outcomes with minimal risk of mechanical failure.

Results of Hip Arthroplasty Using a COREN Stem at a Minimum of Ten Years

  • Joon Soon Kang;Yoon Cheol Nam;Dae Gyu Kwon;Dong Jin Ryu
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.211-218
    • /
    • 2022
  • Purpose: We report on the 10-year clinical hip function and radiologic outcomes of patients who underwent hip arthroplasty using a COREN stem. Materials and Methods: A consecutive series of 224 primary cementless hip arthroplasty implantations were performed using a COREN stem between 2009 and 2011; among these, evaluation of 128 hips was performed during a minimum follow-up period of 10 years. The mean age of patients was 65.4 years (range, 40-82 years) and the mean duration of follow-up was 10.8 years (range, 10-12 years). Evaluation of clinical hip function and radiologic implant outcomes was performed according to clinical score, thigh pain, and radiologic analysis. Results: Dramatic improvement of the mean Harris hip score (HHS) from 59.4 preoperatively to 93.5 was observed at the final follow-up (P≤0.01). Stable fixation was demonstrated for all implants with no change in position except for one case of Vancouver type B2 periprosthetic femur fracture. A radiolucent line (RLL) was observed in 16 hips (12.5%). Thigh pain was observed in only two hips (1.6%) at the final follow-up. There were no cases of osteolysis around the stem. The survival rate for the COREN stem was 97.7%. Conclusion: Good long-term survival with excellent clinical and radiological outcomes can be achieved using the COREN femoral stem regardless of Dorr type.

Superior Gluteal Artery-pedicled Iliac Crest for the Treatment of Avascular Necrosis of Femoral Head (상둔 동맥 혈관경 후방 장골릉 골 이식을 이용한 대퇴골 두 무혈성 괴사의 치료)

  • Lee, Sang-Uk;Song, Seok-Whan;Suh, Yoo-Jun;Park, Seung-Bum
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.42-47
    • /
    • 2008
  • Introduction: To evaluate the efficacy of superior gluteal artery-pedicled iliac crest for the treatment of avascular necrosis of femoral head. Material & Method: From January 2001 to October 2001, we used the superior deep branches of superior gluteal artery for the pedicled posterior iliac crest bone graft to revascularize the avascular femoral head in 4 patients. They were 1 man and 3 women, and the mean age of the patients was 34 years (range, 27 to 60). The average follow-up after surgery was over 57 months (range, 15 to 82). We analyzed the clinical results by the Harris hip score, and evaluated the vascularity of the femoral head by radiographic methods. Results: All cases showed no evidence of collapse on femoral heads and good revascularizations on the radiographic images. The average Harris hip score was 88.5 points. There was no complication. Conclusion: The revascularization procedure using the superior gluteal artery-pedicled posterior iliac crest was thought to be one of the effective and promising techniques for the treatment of the avascular necrosis of femoral head.

  • PDF

A Case Report on a Patient of Bilateral Avascular Necrosis of Femur Head, Treated with Korean Medicine and Hip Joint Fascia Chuna Therapy (한방 치료 및 고관절 경근 추나로 호전된 양측성 대퇴골두 무혈성 괴사 환자의 치험 1례)

  • Park, Jae-Hong;Oh, Eun-Young;Park, Su-A;Shin, Yoo-Bin;Kim, Young-Jun
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.9 no.1
    • /
    • pp.115-124
    • /
    • 2014
  • Objectives : The aim of this study is to report the improved case of bilateral avascular necrosis(AVN) of femur head treated with Korean medicine and Fascia Chuna Therapy Methods : The patient diagnosed with bilateral AVN is hospitalized at department of korean rehabilitation medicine, Samse hospital of korean medicine. The subject is treated by herbal medicine, acupuncture, SBV and hip joint gyoung-geon chuna. This study was measured by visual analogue scale(VAS) score, walking time without pain per 6 minutes and harris hip score(HHS). Results : The patient showed decreased VAS score, HHS and improved walking time without pain per 6 minutes after treated with korean medicine and hip joint Fascia Chuna Therapy. Conclusions : The patient showed reduced pain and positive effect on activities of daily living.

  • PDF

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.