• 제목/요약/키워드: Harmonics suppression

검색결과 88건 처리시간 0.029초

고조파 억제용 고온초전도 평면형 11-극 저역통과 필터의 제작 (Planar type high-$T_{c}$ Superconductor 11-pole Lowpass Filter for Suppression of Harmonics)

  • 강광용;김철수;곽민환
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.159-162
    • /
    • 2002
  • The eleventh-order coupled line lowpass filter(LPF) was designed to suppress harmonics and spurious signals. The microstrip type LPF was fabricated using a high-$T_{c}$ superconductor(HTS) $YBa_{2}$$Cu_{3}$$O_{7-x}$(YBCO) thin film with the $CeO_{2}$ buffer layer which was deposited on the sapphire ($Al_{2}O_{3}$) substrate of 30 x 30 $mm^{2}$. The coupled-line type LPF was designed for 1.2 GHz of cutoff frequency with 0.01 dB of ripple level at passband. The fabricated HTS LPF shows excellent attenuation characteristics in stopband of 1.2~9.5GHz (7-attenuation poles in the stopband), and shows low insertion loss (0.2 dB) and return loss (17.1 dB) in the pass- band. These measured results match well with those obtained by the EM simulation. This clearly demonstrates that the HTS LPF can suppress harmonics and spurious signals effectively.

  • PDF

PBG 구조를 이용한 대역통과 여파기 고조파 억제에 관한 연구 (Harminic Suppression of Band Pass Filter Using Photonic Band Gap Structure)

  • 서철헌
    • 대한전자공학회논문지TC
    • /
    • 제41권1호
    • /
    • pp.69-72
    • /
    • 2004
  • 접지면에 PBG와 Aperture를 설치함으로써 고성능 대역통과 여파기를 설계하였다. 대역통과 여파기의 하모닉 특성은 PBG 구조에 의하여 개선되었고 대역폭은 Aperture에 의하여 확대되었다. 세가지 크기를 갖는 PBG 구조가 결합되어 새로운 PBG 구조가 도출되었다. 설계 중심 주파수는 2.2 GHz이었고 대역폭은 Aperture에 의하여 $40\%$ 확대되었다.

형광등용 인버터 시스템의 고조파 저감에 관한 연구 (A study on reducing the harmonics in inverter system for fluorescent lamp)

  • 박찬근;김종윤;전내석;박정환;이성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1199-1201
    • /
    • 2000
  • This paper proposes a harmonics reducing circuit for fluorescent lamp inverters using hybrid type smoothing circuit with pumping and smoothing capacitors. A waveform of full-wave rectification used as a direct current power supply at fluorescent lamp inverters contains a lot of harmonic wave from inrush current which is generated near the maximum of input voltage with purse shape when voltage smoothing capacitor is charged. Therefore, in order to suppress inrush current which will result in harmonic wave. this paper proposes a method to control abrupt charging current by use of charging voltage at pumping capacitor. The suppression of harmonics generation at lamp current is confirmed through simulations.

  • PDF

교류 전기철도 전력계통의 고조파 예측량 계산 (Estimation of Harmonics on Power System of AC Electric Railway)

  • 송진호;황유모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권2호
    • /
    • pp.68-79
    • /
    • 2003
  • We estimated harmonics on power system of AC railway based on quantitatively measured harmonics and investigated the need of facilities for harmonics reduction. In order to analysis harmonics which inflow into power system due to increase in collector voltages and harmonic currents generated from the train when the railway is in operation, the railway system Is sectioned into power supply, railway line, AT, sectioning Post and subsectioning post. For analysis of extension of currents resulting from the railway loads, PWM converter, VVVF inverter and the feeder system are modeled based on the dynamic node technique(DNT). In order to test the usefulness of the DNT for analysis of harmonic effects, the measured harmonic currents and harmonic magnification ratios at the S/K substation are compared with simulation results using DNT modelling, which include the results for two cases with and without filters for suppression of harmonic currents. When 8 cars(4M4T) are in operation, the total sum of harmonic currents resulting from the train at M and T phases, which inflow into the substation along with the railway line, is calculated. Using the harmonics analysis program for railway feeder system with these data, the total harmonic distortion factor(710) at the outgoing point of KEPCO substation is computed. The calculation shows that when the maximum THD at the receiving point of H/K substation was 0.0443% which is much lower than 1.5% which is the allowable value of KEPCO at 154kV as well as IEEE-519 above 132kV This result indicates that any measure for harmonics reduction in Incheon International Airport Railway is not needed.

Voltage Distortion Suppression for Off-grid Inverters with an Improved Load Current Feedforward Control

  • Geng, Yiwen;Zhang, Xue;Li, Xiaoqiang;Wang, Kai;Yuan, Xibo
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.716-724
    • /
    • 2017
  • The output voltage of an off-grid inverter is influenced by load current, and the voltage harmonics especially the 5th and 7th are increased with nonlinear loads. In this paper, to attenuate the output voltage harmonics of off-grid inverters with nonlinear loads nearby, a load current feedforward is proposed. It is introduced to a voltage control loop based on the Positive and Negative Sequence Harmonic Regulator (PNSHR) compensation to modify the output impedance at selective frequencies. The parameters of the PNSHR are revised with the output impedance of the off-grid inverter, which minimizes the output impedance of the off-grid inverter. Experimental results verify the proposed method, showing that the output voltage harmonics caused by nonlinear loads can be effectively suppressed.

Size and Harmonic Reduced Wilkinson Balun Using Parallel Coupled Line with Open Stub

  • Lee, Won-Kyun;Hwang, Hee-Yong
    • Journal of electromagnetic engineering and science
    • /
    • 제14권4호
    • /
    • pp.387-392
    • /
    • 2014
  • In this paper, a size-reduced Wilkinson balun with wide harmonic-suppressed band is presented. An accurate analysis of the parallel coupled line with an open stub (PCL-OS) is carried out. The PCL-OS structure shows excellent low pass filter and harmonic-suppression characteristics, which is useful for designing a low pass filter unit cell (LUC) with a reduced size. The designed Wilkinson balun at a 2.45 GHz center frequency not only shows an excellent harmonic suppression including the 5th harmonics up to 14 GHz over 15 dB, but it also has an area reduced to 48% of the conventional one.

고조파가 억제된 5.8 GHz 협대역 대역통과 여파기 (Design of a 5.8 GHz Narrow Band-pass Filter with Harmonics Suppression)

  • 윤기철;이종철
    • 한국통신학회논문지
    • /
    • 제33권2A호
    • /
    • pp.167-173
    • /
    • 2008
  • 본 논문에서는 $\{lambda}$g/4 단락형 및 ${\lambda}$g/2 개방형 스터브를 이용한 협대역 대역통과 여파기를 제안한다. 스터브 대역 통과 여파기를 협대역으로 구현하기 위해, 스터브의 임피던스 값 변화 없이 스터브 위치를 변화시켜, 그에 따른 Qe (External quality factor) 값을 이용하여 협대역 대역통과 여파기를 구현한다. 또한, 협대역 대역통과 여파기의 전승선로 부분에 T-형태의 대역저지 여파기를 집적시켜, 여파기에서 발생하는 고조파들을 억제한다. 제안된 여파기의 중심 주파수는 5.8 GHz, 대역폭은 10 % 이며, ${\lambda}$g/4 단락형에서의 삽입손실은 2.1 dB, 반사손실은 18 dB이고, ${\lambda}$g/2 개방형에서의 삽입손실은 1.2 dB, 반사손실은 21.9 dB의 측정결과들을 얻는다.

고조파 억압을 위한 접힌 피드 구조를 갖는 SIR CPW 대역통과 여파기 (SIR CPW Bandpass Filter with Folded Feed Structure for Suppressing Spurious Harmonics)

  • 박광선;이창언;천동완;이진택;신철재
    • 한국전자파학회논문지
    • /
    • 제15권2호
    • /
    • pp.159-164
    • /
    • 2004
  • 본 논문에서는 SIR CPW 대역통과 여파기의 고조파 억압을 위한 접힌 피드 구조를 제안하였고 이를 이용해 SIR CPW 대역통과 여파기를 설계하였다. 제안된 접힌 피드 구조는 넓은 저지대역을 갖는 저역통과 여파기의 특성을 보이며, CPW 대역통과 여파기에서 고조파 억압에 매우 유용하게 이용될 수 있다. 시뮬레이션 및 측정결과 접힌 피드 구조를 갖는 SIR CPW 대역통과 여파기는 5.8 f$_{0}$까지 -20 dB 이 하로 고조파를 억압하는 우수한 특성을 보임을 알 수 있었다.다.

Design and Implementation of a Multi Level Three-Phase Inverter with Less Switches and Low Output Voltage Distortion

  • Ahmed, Mahrous E.;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.593-603
    • /
    • 2009
  • This paper proposes and describes the design and operational principles of a three-phase three-level nine switch voltage source inverter. The proposed topology consists of three bi-directional switches inserted between the source and the full-bridge power switches of the classical three-phase inverter. As a result, a three-level output voltage waveform and a significant suppression of load harmonics contents are obtained at the inverter output. The harmonics content of the proposed multilevel inverter can be reduced by half compared with two-level inverters. A Fourier analysis of the output waveform is performed and the design is optimized to obtain the minimum total harmonic distortion. The full-bridge power switches of the classical three-phase inverter operate at the line frequency of 50Hz, while the auxiliary circuit switches operate at twice the line frequency. To validate the proposed topology, both simulation and analysis have been performed. In addition, a prototype has been designed, implemented and tested. Selected simulation and experimental results have been provided.

RF NOISE SUPPRESSION ON COPLANAR TRANSMISSION LINE USING LOSS GENERATION OF THE SOFT MAGNETIC FILMS

  • Kim, Ki-Hyeon;Shinji Ikeda;Masahiro Yamaguchi;Arai, Ken-Ichi;Hideaki Nagura;Shigehiro ohnuma
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2002년도 동계연구발표회 논문개요집
    • /
    • pp.200-201
    • /
    • 2002
  • Recently, a countermeasure for the electromagnetic noise emission on RF integrated transmission line using the loss generation of ferromagnetic thin films is briefly suggested$\^$1,2/. Without the magnetic film, the noise harmonics of the signal pass through the transmission line with only a little attenuation. The ideal role of magnetic film is not to raise insertion losses in the pass-band and to give as large attenuation as possible to eliminate the noise harmonics at the stop-band, the frequency range higher than the meaningful signal as shown in Fig. 1. and Fig. 2. (omitted)

  • PDF