• 제목/요약/키워드: Harmonics simulation

검색결과 507건 처리시간 0.024초

능동 전력 필터에 의한 유도모터 구동 전류형 인버터의 구형파 전류보상 (A Square Wave Current Compensation of Current Source Induction Motor drives Using Active Power Filter)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.133-136
    • /
    • 2000
  • Current Source Inverter(CSI) operated in square wave mode is more efficient than the PWM CSI because of increased cost greater complexity of control algorithm, and substantial switching losses EMI. But the square wave output current of CSI rich in low order harmonics produce motor torque ripples. Therefore in this paper describes the active power filters for square wave current compensation of current source induction motor. Also extended current synchronous detection(ECSD) as compensation algorithm is proposed. To confirm the validity o proposed system some simulation results are presented and discussed.

  • PDF

부하 특성을 고려한 TCSC 전력송전 시스템의 고조파 해석 (Harmonic Analysis of TCSC Power Transmission System considering Load Characteristics)

  • 정교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.468-471
    • /
    • 2000
  • This paper investigates the harmonics of TCSC power transmission system having nonlinear VI characteristic loads. Nonlinear VI characteristic components are modelled with Nortons harmonic current sources. The system parameters such as line impedances admittances and node voltages and the thyristor switching action are described in complex Fourier series. EMTP simulation studies with a detailed three-phase TCSC power transmission system are also performed in order to verify the harmonic analysis at the steady state.

  • PDF

전류제어 PWM에 의한 단상 인버어터 제어 (Current-controlled PWM for voltage source single phase inverter)

  • 박훈경;이광원;이상혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.277-280
    • /
    • 1988
  • In the current-controlled PWM, the actual current tracks the sinusoidal reference wave within desired hyeteresis band. This paper au99e61s the current control scheme for voltage-fed single-phase inverter and presents the simulation results. It is expected that the inverter with this control method produces no significant lower-order harmonics.

  • PDF

FREQUENCY SELECTIVE RECURSIVE LP OF HARMONIC SPECTRA

  • SeungHyonNam
    • 지구물리
    • /
    • 제4권4호
    • /
    • pp.231-238
    • /
    • 2001
  • In this paper, an efficient LP method ofr discrete harmonic spectra is proposed and discussed. A new efficient LP method is a combination of recursive and frequency selective LP. While the recursive LP provides better spectral matching in spectral hills, frequency selective LP eliminates numerical instability and improves spectral matching when the harmonics are confined in the low frequncy region. The proposed LP method is applied to the HILN coder. Simulation results using a verification model(VM) software for real audio signals show a definite trend of significant improvement.

  • PDF

고역률 제어를 위한 단산 전압원 PWM 컨버터에 관한 연구 (A study of Single-phase Voltage Source PWM Converter for High Power Factor)

  • 류성식;손진근;정을기;김형원;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.362-365
    • /
    • 1999
  • In this paper, the method of reducing harmonics and correcting of power factor in single PWM converter associated with diode rectifier and boos converter is studied. The ac-dc converter in which the harmonic distortion in the input current is reduced using a third harmonic injected PWM is proposed. A lower switching power loss and easy configuration o control circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[KHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

Analysis of Multi Level Current Source GTO Inverter for Induction Motor Drives

  • Arase, Takayuki;Matususe, Kouki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.535-540
    • /
    • 1998
  • This paper discusses a triple stage current source GTO inverter system for high power motor drives. The energy rebound circuit of the triple stage inverter not only controls the spike voltage of the GTO inverter but also facilitates PWM control of the thyristor rectifier operated at unity fundamental input power factor. Based on Pspice simulation and experiments, the principles and PWM pulse pattern for removing specific lower harmonics in the inverter's output current are discussed in detail.

  • PDF

RESEARCH OF AN ACTIVE FILTER BASED BALANCED POWER SUPPLY SYSTEM FOR RAIL WAY TRACTION

  • Zeng, Guohong;Hao, Rongtai
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.797-801
    • /
    • 1998
  • This paper presents a balanced 3/1 supply scheme for electric railway. By employing an active filter, the current of the three-phrase delivery system is balanced while the load is single phrase, which makes it possible for the traction system to behave like a pure-resistance load, with unity power factor and no harmonics. Simulation results are present to verify the scheme's topology and control strategies.

  • PDF

전기 철도차량용 보조전원장치의 컨버터에 관한 연구 (A study on the converter of auxiliary power supply for electric railway vehicles)

  • 김재문;김양수;이종성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.467-468
    • /
    • 2007
  • This paper describes characteristics of converters of auxiliary power supply for electric railway vehicles. Auxiliary power supply is called Static Inverter(SIV) which supplied lamps, air conditioning and heat equipments, control systems, etc. Simulation results shows that line No.1 cheon contains low harmonics compared with those of KTX.

  • PDF

Basic Characteristic of 5-level Inverter with Different Divided DC Link Voltage

  • Matsuse, Kouki;Matsumoto, Takafumi;Kodera, Yuji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.179-183
    • /
    • 2013
  • This paper report on experimental results of 5-level inverter by DC divided link voltage. We have alreday reported that DC divided link valtage comes to be able to reduse harmonic of out line voltage. So we tested whether DC divided link voltage can reduce harmonics in experimental setup. This paper shows simulation results and experimental results. And we confirmed that DC divided link voltage can also apply in experimental setup.

Frequency Selective Recursive LP of Discrete Harmonic Spectra for Audio Cording

  • Nam, Seung-Hyon
    • 공학논문집
    • /
    • 제5권1호
    • /
    • pp.37-44
    • /
    • 2004
  • n this paper, an efficient LP method for discrete harmonic spectra is proposed and discussed. A new efficient LP method is a combination of recursive and frequency selective LP. While the recursive LP provides better spectral matching in spectral hill, frequency selective LP eliminates numerical instability and improves spectral matching when the harmonics are confined in the low frequency region. The proposed LP method is applied to the HILN coder. Simulation results using a verification model(VM) software for real audio signals show a definite trend of significant improvement.

  • PDF