• 제목/요약/키워드: Harmonics simulation

검색결과 507건 처리시간 0.025초

전력 능동 필터의 설계 및 시뮬레이션 (Design and Simulation of Active Power Filter)

  • 정동열;박종연;방선배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2629-2632
    • /
    • 2003
  • This paper presents the harmonics rejection technique and the simulation of a active power filter using power operational amplifier. The proposed active power filter consists of CT(current transformer), harmonics detector and harmonics amplifier. The harmonics detector is a high pass filter using a GIC(Generalized Impedance Converter). The harmonics amplifier consists of a power operational amplifier and passive filters. The simulation has been implemented by OR-CAD program. It is examined whether the proposed active power filter can be realized or not through simple experiments.

  • PDF

고속전철 차량에서 발생한 고조파 파급영향과 그 대책에 관한 연구 (A study on propagation effect and countermeasure of the harmonics generated in high speed traction)

  • 박수만;김재철;강창원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.59-61
    • /
    • 2003
  • This paper demonstrates an analysis of harmonics at the high speed railway substation and proved on this countermeasure using the PSCAD/EMTDC simulation tool. First, high speed railway feeding system is composed using PSCAD/EMTDC electrical railway feeding system model in advance. Second, This paper applications line capacitance values as feeder-trolley, trolley-rail and feeder-rail to analysis harmonics more accuracy in advance did not application. This capacitance values calculate using the EMTP(Electro Magnetic Transient Program). Third, the tractions are arranged in the section that substation supplies power, and this paper take the simulation each case(fractions composition amount) to see harmonic propagation from traction to substation. As a result, generated harmonics at traction can confirmed that harmonics did not reduce at utility source. This harmonics have an influence on bulk power system. Finally, this paper introduces the methods of harmonics effect minimum. This paper proved harmonics reduce effect through the passive filters application.

  • PDF

누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향 (Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement)

  • 길경석;한주섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

시간에 따라 변하는 전기로 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the Electric Arc Furnace Loads)

  • 김경철;진성은;이주홍;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.9-17
    • /
    • 2006
  • 규모가 큰 제철소는 전기로와 같은 비선형 부하를 가지고 있다. 고조파 측정 결과로 고조파는 시간에 따라 변하는 특성이 관측되었다. 순시치 측정에 의한 고조파 평가는 측정 순간에 따라 고조파가 다를 수 있으므로 모호한 결과를 초래할 수 있다. 시간에 따라 변하는 고조파를 해결하기 위해 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 고조파 시뮬레이션은 사례연구 시스템의 전압 및 전류 왜곡을 평가하기 위해 이용되었다. 본 논문에서는 전기로 부하의 고조파 현장 측정, 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가, 시간에 따라 변하는 고조파의 시뮬레이션을 심도 있게 다루고자 한다. 고조파 해석 프로그램인 EDSA는 사례 연구에 시뮬레이션 도구로 사용되었다.

Harmonic Analysis of a Modular Multilevel Converter Using Double Fourier Series

  • Quach, Ngoc-Thinh;Chae, Sang Heon;Ahn, Jin Hong;Kim, Eel-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.298-306
    • /
    • 2018
  • This paper presents a harmonic analysis of the modular multilevel converter (MMC) using a double Fourier series (DFS) algorithm. First, the application of DFS for harmonic calculation in the MMC is made by considering the effect of arm inductor. The analytical results are then confirmed by comparing with the simulation results of using the fast Fourier transform (FFT) algorithm. Finally, distribution of harmonics and total harmonic distortion (THD) in the MMC will be analyzed in three cases: harmonics versus number of levels of MMC, harmonics versus total switching frequency and harmonics versus modulation index. The simulation results are performed in the PSCAD/EMTDC simulation program in order to verify the analytical results obtained by Matlab programming.

고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads)

  • 김경철;진성은;이주홍;이일무;김주락
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.272-277
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the contol synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

현장시험에 의한 고속전철 부하의 고조파 시뮬레이션에 관한 연구 (A Study on the Harmonics Simulation of the High Speed Electric Train Loads by Field Tests)

  • 김경철;김유준
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.40-47
    • /
    • 2007
  • 고속전철 부하는 동기 전동기를 제어하기 위해 컨버터와 인버터를 포함한 많은 비선형 부하를 가지고 있다. 고조파 측정 결과로 고조파는 시간에 따라 변하는 특성이 관측되었다. 순시치 측정에 의한 고조파 평가는 측정 순간에 따라 고조파가 다를 수 있으므로 모호한 결과를 초래할 수 있다. 시간에 따라 변하는 고조파를 해결하기 위해 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 고조파 시뮬레이션은 사례연구 시스템의 전압 및 전류 왜곡을 평가하기 위해 이용되었다. 본 논문에서는 고속전철 부하의 고조파 현장 측정, 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가, EDSA 프로그램을 사용한 시뮬레이션을 심도있게 다루고자 한다.

영구자석형 동기전동기를 위한 고조파 자속을 고려한 공간전압벡터 제어 (Space vector control considering flux harmonics for PMSM)

  • 박익동;이제희;허욱열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.508-511
    • /
    • 1997
  • Recently the development of motor speed control systems with both good dynamic performance and simple implementation has been required. The vector control scheme considering flux harmonics for the permanent-magnet AC servo motor having low inertia, low weight, and high efficiency is proposed. To reduce the torque harmonics, current harmonics is employed. The vector control strategy is verified through digital simulation.

  • PDF

현장 측정에 의한 가정집 부하의 고조파 특성에 관한 연구 (A Study on the Hormonic Characteristics of Typical Household Loads by Field Measurements)

  • 김경철;오경훈;최형범
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.100-106
    • /
    • 2008
  • 일반 가정집 부하는 컴퓨터, 비디오, 냉장고, 마이크로웨이브 오븐, TV, 오디오 등의 많은 비선형 부하를 가지고 있다. 이들 비선형 부하는 고조파 전류를 발생시키고, 전력계통의 정현파 전압을 왜곡시킨다. 고조파 측정 결과로 고조파는 시간에 따라 변하는 특성이 관측되었다. 시간에 따라 변하는 고조파를 해결하기 위해서 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 본 논문에서는 가정집 부하의 고조파 현장 측정과 EDSA 프로그램을 사용한 고조파 시뮬레이션을 심도 있게 다루고자 하였다.

모멘트 정합 방법(Moment Matching Method)을 이용한 전기철도 급전시스템의 고조파 평가 (Harmonics Assessment for an Electric Railroad Feeding System using Moments Matching Method)

  • 이준경;이승혁;김진오
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.1-7
    • /
    • 2007
  • Generally, an electric railroad feeding system has many problems due to the different characteristics in contrast with a load of general three-phase AC electric power system. One of them is harmonics problem caused by the switching device existing in the feeding system, and moreover, the time-varying dynamic loads of rail way is inherently another cause to increase this harmonics problem. In Korea power systems, the electric railroad feeding system is directly supplied from the substation of KEPCO. Therefore, if voltages fluctuation or unbalanced voltages are created by the voltage and current distortion or voltage drop during operation, it affects directly the source of supply. The trainloads of electric railway system have non-periodic but iterative harmonic characteristics as operating condition, because the electric characteristic of the electric railroad feeding system is changed by physical conditions of the each trainload. According to the traditional study, the estimation of harmonics has been performed by deterministic way using the steady state data at the specific time. This method is easy to analyze harmonics, but it has limits in some cases which needs an assessment of dynamic load and reliability. Therefore, this paper proposes the probabilistic estimation method, moments matching method(MW) in order to overcome the drawback of deterministic method. In this paper, distributions for each harmonics are convolved to obtain the moments and cumulants of TDD(Total Demand Distortion), and this can be generalized for any number of trains. For the case study, the electric railway system of LAT(Intra Airport Transit) in Incheon International Airport is modeled using PSCAD/EMTDC dynamic simulator. The raw data of harmonics for the moments matching method is acquired from simulation of the LAT model.