Dynamic Characteristics of a System Composed of a Supporting Structure and Subsystems (지지구조물과 부시스템으로 이루어진 계의 동적 특성)

  • Lee, Gun-Myung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.4
    • /
    • pp.406-411
    • /
    • 2016
  • The natural frequencies and mode shapes of a system composed of subsystems on a supporting structure have been derived approximately. The system is modeled as a discrete system, and it is assumed that the masses of subsystems are much smaller than the mass of a supporting structure. It has been found that the fundamental frequency corresponds to the supporting structure, and each higher frequency corresponds to each subsystem. A relation between the vibration amplitudes of the supporting structure and subsystems is also derived for the case when the supporting structure is excited by a harmonic force.

STSAT RWA Micro-Vibration Test and Analysis (과학기술위성 반작용휠의 미소진동 측정 및 분석)

  • Oh, Shi-Hwan;Nam, Myeong-Ryong;Park, Yon-Mook;Yim, Jo-Ryeong;Keum, Jung-Hoon;Rhee, Seung-Wu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.695-698
    • /
    • 2004
  • STSAT RWA (Reaction Wheel Assembly) micro-vibration is measured using KISTLER dynamic plate that can provide the time signals of three orthogonal forces and torques simultaneously up to 400Hz. In the post-processing, measured data are evaluated with respect to the wheel spin rate in both time and frequency domains, and the static/dynamic unbalances are evaluated from the extracted first harmonic component. Also the friction torque profile at each wheel speed is estimated from the measured data. Several higher order harmonic components are observed, that comes from its rotor shape as well as the wheel bearing characteristics. One of the most peculiar characteristics of this wheel is that the dynamic properties of two radial unbalance components are much different from each other as the RWA mounting configuration on a spacecraft is different from conventional RWA mounting configuration. Rocking mode is not appeared below 400Hz for all operating speed because the wheel size is very small. The post-processed results will be used for jitter analysis of STSAT due to RWA micro-vibration.

  • PDF

Vibration Characteristics of Liquid Column Vibration Absorber with Various Area Ratio (다양한 수평 수직 단면적비를 가지는 LCVA의 진동특성 평가)

  • Chung, Lan;Lee, Joung-Woo;Park, Hyun-Chin;Lee, Sang-Hyun;Woo, Sung-Sik;Cho, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.121-125
    • /
    • 2007
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA is larger than the calculated one when the area ratio is larger than 1. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF

Performance evaluation of inerter-based damping devices for structural vibration control of stay cables

  • Huang, Zhiwen;Hua, Xugang;Chen, Zhengqing;Niu, Huawei
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.615-626
    • /
    • 2019
  • Inerter-based damping devices (IBBDs), which consist of inerter, spring and viscous damper, have been extensively investigated in vehicle suspension systems and demonstrated to be more effective than the traditional control devices with spring and viscous damper only. In the present study, the control performance on cable vibration reduction was studied for four different inerter-based damping devices, namely the parallel-connected viscous mass damper (PVMD), series-connected viscous mass damper (SVMD), tuned inerter dampers (TID) and tuned viscous mass damper (TVMD). Firstly the mechanism of the ball screw inerter is introduced. Then the state-space formulation of the cable-TID system is derived as an example for the cable-IBBDs system. Based on the complex modal analysis, single-mode cable vibration control analysis is conducted for PVMD, SVMD, TID and TVMD, and their optimal parameters and the maximum attainable damping ratios of the cable/damper system are obtained for several specified damper locations and modes in combination by the Nelder-Mead simplex algorithm. Lastly, optimal design of PVMD is developed for multi-mode vibration control of cable, and the results of damping ratio analysis are validated through the forced vibration analysis in a case study by numerical simulation. The results show that all the four inerter-based damping devices significantly outperform the viscous damper for single-mode vibration control. In the case of multi-mode vibration control, PVMD can provide more damping to the first four modes of cable than the viscous damper does, and their maximum control forces under resonant frequency of harmonic forced vibration are nearly the same. The results of this study clearly demonstrate the effectiveness and advantages of PVMD in cable vibration control.

Beam Vibration Suppression with Translational and Rotational Damped Dynamic Vibration Absorbers (병진 및 회전 감쇠동흡진기를 사용한 보의 진동저감)

  • Park, Sung Gyu;Lee, Shi Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.721-728
    • /
    • 2016
  • The combined rotational and translational dynamic vibration absorbers (DVA) with no dampers for the beam vibration control can effectively isolate the vibration within the external excitation force region. This paper investigates the damping efficacy for the combined rotational and translational dynamic vibration absorbers to impose some robustness to the DVA system for the excitation force frequency variation. The beam is assumed to be subjected to a concentrated harmonic excitation force. The solution to the problem is found based on Galerkin method.

Free Vibrations of Arches in Rectangular Coordinates (직교좌표계에 의한 아치의 자유진동 해석)

  • Lee, Tae-Eun;Ahn, Bae-Soon;Kim, Young-Il;Lee, Byoung-Koo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.394.2-394
    • /
    • 2002
  • The differential equations governing free vibrations of the elastic arches with unsymmetric axis are derived in the rectangular coordinates rather than in polar coordinates, in which the effect of rotatory inertia is included. Frequencies and mode shapes are computed numerically for parabolic arches with both clamped ends and both hinged ends. Comparisons of natural frequencies between this study and SAP 2000 are made to validate theories and numerical methods developed herein. (omitted)

  • PDF

A Study on the Stiffness Estimation in Soft Tissue Using Speckle Brightness Variance Tracking (초음파 의료영상에서 스페클의 시간적 밝기 변화를 이용한 연조직의 stiffness를 추정하는 방법에 대한 연구)

  • 안동기;박정만;권성재;정목근
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.141-149
    • /
    • 2003
  • This paper proposes a method of measuring and imaging the stiffness of human soft tissue to diagnose cancers or tumors which have been difficult to detect in ultrasound B-mode imaging systems. To measure the soft tissue stiffness, sinusoidal vibrations are applied to it, and the magnitude of its mechanical vibration is determined by estimating the temporal variation of speckle pattern brightness in ultrasound B-mode images. It is verified by simulation and experiment that the proposed method can estimate the relative tissue stiffness from B-mode images with a relatively small amount of computation.

Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-Horizontal Area Ratio (수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안)

  • Woo, Sung-Sik;Lee, Sang-Hyun;Chung, Lan;Lee, Joung-Woo;Cho, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.653-658
    • /
    • 2008
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the Case01 to 19, the standard deviation($s_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the Case21 to 61, the standard deviation ($s_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

  • PDF

Proposition to Natural Frequency of Liquid Column Vibration Absorber with Vertical-horizontal Area Ratio (수직-수평부 단면적비에 따른 동조액체기둥형 감쇠장치의 고유진동수 산정식 제안)

  • Woo, Sung-Sik;Chung, Lan;Lee, Joung-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.119-126
    • /
    • 2009
  • LCVA has an advantage that its natural frequency can be easily controlled by changing the area ratio of the vertical column and horizontal part. The previous studies investigated the dynamic characteristics of the LCVA under harmonic load. This study experimentally obtained the first and second mode natural frequencies of the LCVA from shaking table tests using white noise and compared the values with the ones by previous study. Test results show that the measured first mode natural frequency of the LCVA has a different value compared with calculated one. The effective length($L_e$) was revised using by power equation. In the case01 to 19, the standard deviation($S_r$) is 4.7292 and the coefficient of correlation(r) is 0.9856. In the case21 to 61, the standard deviation($S_r$) is 14.2143 and the coefficient of correlation(r) is 0.9935. The second mode frequency increases with the increasing area ratio, which is due to the sloshing motion effect resulting from the large area of the vertical column.

Modeling of a Transmission Control Cable for Vibration Analysis (트랜스미션 컨트롤 케이블의 진동 해석을 위한 모델링)

  • Lee, Byoung-Soo;Choi, Hae-Woon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.550-557
    • /
    • 2008
  • A transmission control cable connects the transmission control arm and the control lever mechanically and transfers control effort exerted by a driver to the transmission. It also transfers vibration generated by the engine to the passenger room through mechanical connection. To understand vibration and noise transfer mechanism and to further find a way to suppress the transmission of vibration effectively, a dependable dynamic vibration model is a necessity. A vibration model for a transmission control cable is developed and a simulation study has been conducted to obtain mode frequencies and a transmittability. The resonance frequencies obtained by an harmonic analysis is compared with the noise level measurement data. The measurement agrees with the simulation result thus ensures the reliability of the model.