• Title/Summary/Keyword: Harmonic source

Search Result 513, Processing Time 0.038 seconds

A Study of Series Active Power Filter Compensating Unbalanced Source Voltage in 3phase-3wire system (불평형 전원전압을 보상하는 3상3선식 직렬형 능동전력필터에 관한 연구)

  • Oh, Jae-Hoon;Kim, Young-Seok;Han, Yoon-Seok;Won, Chung-Yuen;Chol, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.319-322
    • /
    • 2001
  • In this paper, a 3phase-3wire series active power filter compensating current harmonics and unbalanced source voltages is presented. The system is composed of series active power filter and shunt passive filters that are tuned 5th and 7th harmonics. In this system, series active power filter improves harmonic compensation characteristics of the shunt passive filters and compensates the unbalanced source voltages. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by a performance function, and compensation voltage for the unbalanced source voltage is calculated in based on the synchronous reference frame. Some results obtained from the experimental model using the proposed method are presented to demonstrate and confirm its validity.

  • PDF

A Study on the Analysis of Harmonic Injection and Emission for Power System (전력계통 고조파 유입 유출 분석에 관한 연구)

  • Wang, Yong-Peel;Jeong, Jong-Won;Kim, Se-Dong;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

Development of Measurement System for Harmonic Analysis of Electric Equipment (전기설비의 고조파 분석을 위한 측정 시스템의 개발)

  • Yoo, Jae-Geun;Lee, Sang-Ik;Jeon, Jeong-Chay
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.259-261
    • /
    • 2002
  • Recently, according to the spread of semiconductor applied technology like motor speed control contrivance, power conversion installation and so on, harmonic ingredients occurred in switching operation flow into a distribution system and increase voltage distortion of distribution system and bring on obstacles like damage, lowering of capability, false operation and so on of various electrical installation. So, in order to consider a countermeasure to limit occurrence quantity of harmonic source, harmonic interception and others, precision measurement and analysis on voltage, current, power, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion and so forth are needed. In this paper monitoring system to measure and analyze power quality connected with power harmonics was developed and it's performance is verified by measuring and analyzing three-phase voltage and current of R, S, T in the three-phase and four-wire system using the developed measurement system.

  • PDF

Analysis of Harmonic Incoming and Outgoing for Transmission System (송전계통 고조파 유입/유출 분석)

  • Wang, Y.P.;Choi, S.Y.;Kwak, N.H.;Jeon, Y.S.;Park, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.561-562
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

A Study on the development of Harmonic reduction filter system from PLC control system (PLC제어 시스템에 의한 고조파 제거용 필터 시스템 개발에 관한 연구)

  • An, Hyo-Seop;Shin, Kwan-Woo;Ko, Seok-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.234-236
    • /
    • 2006
  • In this paper, APF(Active Power Filter) will be treated in order to improve the output current distortion of the AC source. APF generates the harmonic current which contributes to a source side harmonic reduction. We can extract the compensating current of the parallel APF with phase transformations and the proposed current control method. Therefore, the calculation times is short and the control method is simple compared with conventional hysteresis methods. Experimental results verify that the system using the proposed method appers a good performance.

  • PDF

Real-Time Implementation of the EHSX Speech Coder Using a Floating Point DSP (부동 소수점 DSP를 이용한 4kbps EHSX 음성 부호화기의 실시간 구현)

  • 이인성;박동원;김정호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.420-427
    • /
    • 2004
  • This paper presents real time implementation of 4kbps EHSX (Enhanced Harmonic Stochastic Excitation) speech coder that combines the harmonic vector excitation coding with time-separated transition coding. The harmonic vector excitation coding uses the harmonic excitation coding for voiced frames and used the vector excitation coding with the structure of analysis-by-synthesis for unvoiced frames, respectively. For transition frames mixed with voiced and unvoiced signal, we use the time-separated transition coding. In this paper. we present the optimization methods of implementation speech coder on the EMS320C6701/sup (R)/ DSP. To reduce the complex for real-time implementation. we perform the optimization method in algorithm by replacing the complex sinusoidal synthesis method with IFFT. and we apply fully pipelines hand assembly coding after converting it from floating source to fixed source. To generate a more efficient code. we also make use or the available EMS320C6701/sup (R)/ resources such as Fastest67x library and memory organization.

New series Active power filtering system to reduce the harmonic in 3-Phase 3-Wire system (3상 3선식 전력계통의 고조파 저감을 위한 새로운 직렬형 능동 필터 시스템)

  • 한윤석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.119-122
    • /
    • 2000
  • This paper presents a new compensation method of series active power filter. The proposed method applied in the three-phase three-wire system can generate harmonic compensation voltage in front of the harmonic source. Futhermore it is also expended to three-phase four-wire system considering zero-sequence voltage. The compensation principle is described in detail. Experimental result show the validity of the proposed method in the three-phase three-wire system

  • PDF

A Harmonic Reducer(H.R) Converter Connecting a Fuel Cells Micro-Source (연료전지 마이크로 소스와 연계한 Harmonic Reducer(H.R)컨버터)

  • Oum, J.H.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.227-230
    • /
    • 2007
  • 본 연구에서는 연료전지 마이크로 소스와 연계된 Harmonic Reducer(H.R)컨버터 시스템을 제안하였다. 이 시스템에 의하여 마이크로 소스의 ac출력전류를 정현파로 개선할 수 있었다. 또한 H.R컨버터의 dc단전압과 전류의 리플은 Zero Ripple(Z.R)필터를 설치하여 제거할 수 있었다. 본 연구의 타당성을 PSIM 시뮬레이션에 의하여 확인하였으며 그 유용성을 입증하였다.

  • PDF

A study of Single-phase Voltage Source PWM Converter for High Power Factor (고역률 제어를 위한 단산 전압원 PWM 컨버터에 관한 연구)

  • 류성식;손진근;정을기;김형원;전희종
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.362-365
    • /
    • 1999
  • In this paper, the method of reducing harmonics and correcting of power factor in single PWM converter associated with diode rectifier and boos converter is studied. The ac-dc converter in which the harmonic distortion in the input current is reduced using a third harmonic injected PWM is proposed. A lower switching power loss and easy configuration o control circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[KHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

A study of the harmonics evaluation in the test track of Korea High Speed Rail (경부고속철도 시험선구 고조파 예측에 관한 연구)

  • 김길상;오광해;권삼영;이태형
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.241-248
    • /
    • 1998
  • The purpose of this study is to evaluate the harmonics generated from Korea High Speed Rail's trainset and to analyze the effect on the KEPCO power system. This study focuses on the test track of the high speed rail and analyzes 154㎸ transmission line, scott transformer, autotransformer and 27,5㎸ line. The trainset is modeled as a harmonic source attached to the catenary line of the test track. Then, harmonic distortion is calculated. This distortion is compared with the KEPCO's regulations in relation to harmonic.

  • PDF