• 제목/요약/키워드: Harmonic source

검색결과 513건 처리시간 0.051초

불평형 전원전압을 보상하는 3상3선식 직렬형 능동전력필터에 관한 연구 (A Study of Series Active Power Filter Compensating Unbalanced Source Voltage in 3phase-3wire system)

  • 오재훈;김영석;한윤석;원충연;최세완
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2001
  • In this paper, a 3phase-3wire series active power filter compensating current harmonics and unbalanced source voltages is presented. The system is composed of series active power filter and shunt passive filters that are tuned 5th and 7th harmonics. In this system, series active power filter improves harmonic compensation characteristics of the shunt passive filters and compensates the unbalanced source voltages. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by a performance function, and compensation voltage for the unbalanced source voltage is calculated in based on the synchronous reference frame. Some results obtained from the experimental model using the proposed method are presented to demonstrate and confirm its validity.

  • PDF

전력계통 고조파 유입 유출 분석에 관한 연구 (A Study on the Analysis of Harmonic Injection and Emission for Power System)

  • 왕용필;정종원;김세동;곽노홍;전영수;박상호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

전기설비의 고조파 분석을 위한 측정 시스템의 개발 (Development of Measurement System for Harmonic Analysis of Electric Equipment)

  • 유재근;이상익;전정채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 2002
  • Recently, according to the spread of semiconductor applied technology like motor speed control contrivance, power conversion installation and so on, harmonic ingredients occurred in switching operation flow into a distribution system and increase voltage distortion of distribution system and bring on obstacles like damage, lowering of capability, false operation and so on of various electrical installation. So, in order to consider a countermeasure to limit occurrence quantity of harmonic source, harmonic interception and others, precision measurement and analysis on voltage, current, power, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion and so forth are needed. In this paper monitoring system to measure and analyze power quality connected with power harmonics was developed and it's performance is verified by measuring and analyzing three-phase voltage and current of R, S, T in the three-phase and four-wire system using the developed measurement system.

  • PDF

송전계통 고조파 유입/유출 분석 (Analysis of Harmonic Incoming and Outgoing for Transmission System)

  • 왕용필;최선영;곽노홍;전영수;박상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.561-562
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

PLC제어 시스템에 의한 고조파 제거용 필터 시스템 개발에 관한 연구 (A Study on the development of Harmonic reduction filter system from PLC control system)

  • 안효섭;신관우;고석보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.234-236
    • /
    • 2006
  • In this paper, APF(Active Power Filter) will be treated in order to improve the output current distortion of the AC source. APF generates the harmonic current which contributes to a source side harmonic reduction. We can extract the compensating current of the parallel APF with phase transformations and the proposed current control method. Therefore, the calculation times is short and the control method is simple compared with conventional hysteresis methods. Experimental results verify that the system using the proposed method appers a good performance.

  • PDF

부동 소수점 DSP를 이용한 4kbps EHSX 음성 부호화기의 실시간 구현 (Real-Time Implementation of the EHSX Speech Coder Using a Floating Point DSP)

  • 이인성;박동원;김정호
    • 한국음향학회지
    • /
    • 제23권5호
    • /
    • pp.420-427
    • /
    • 2004
  • 본 논문에서는 선형예측 잔여신호에 대한 하모닉 벡터 여기 코딩과 시간 대역 분리 혼합 코딩을 결합한 4kbps EHSX (Enhanced Harmonic Stochastic Excitation) 음성부호화기 실시간 구현한 내용을 기술한다. 유성음 구간에서는 하모닉 여기 코딩에 무성음 구간에 대해서는 분석-합성 구조의 벡터 여기 코딩을 사용하였으며, 유/무성음이 혼재하는 전이구간에서는 시간 분리 전이 코딩을 사용하였다. 이 음성부호화기 구현을 위해 부동소수점과 고정소수점을 모두 지원하는 DSP인 TMS320C6701을 사용하였고, 연산량을 줄이기 위해 IFFT를 사용한 저 복잡도 정현파 합성법을 사용하여 알고리즘의 최적화를 이루었으며, 복잡도의 문제가 되는 부분을 고정소수점으로 변환한 후 파이프라인을 적용한 핸드 어셈블리 코딩을 하여 구현에서의 최적화를 이루었다. 또한, 메모리의 효율성을 극대화하기 위해 캐쉬 메모리 할당과 데이터를 내부 메모리에 할당하였고 수학 연산의 최적화를 위해 FastRTS67x 라이브러리를 사용하였다. 개발 환경은 DSP EVM 보드를 사용하였으며 음성 신호의 입·출력 확인으로 동작 및 기능을 검증하여 실시간 구현하였다.

3상 3선식 전력계통의 고조파 저감을 위한 새로운 직렬형 능동 필터 시스템 (New series Active power filtering system to reduce the harmonic in 3-Phase 3-Wire system)

  • 한윤석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.119-122
    • /
    • 2000
  • This paper presents a new compensation method of series active power filter. The proposed method applied in the three-phase three-wire system can generate harmonic compensation voltage in front of the harmonic source. Futhermore it is also expended to three-phase four-wire system considering zero-sequence voltage. The compensation principle is described in detail. Experimental result show the validity of the proposed method in the three-phase three-wire system

  • PDF

연료전지 마이크로 소스와 연계한 Harmonic Reducer(H.R)컨버터 (A Harmonic Reducer(H.R) Converter Connecting a Fuel Cells Micro-Source)

  • 엄준현;정영국;입영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.227-230
    • /
    • 2007
  • 본 연구에서는 연료전지 마이크로 소스와 연계된 Harmonic Reducer(H.R)컨버터 시스템을 제안하였다. 이 시스템에 의하여 마이크로 소스의 ac출력전류를 정현파로 개선할 수 있었다. 또한 H.R컨버터의 dc단전압과 전류의 리플은 Zero Ripple(Z.R)필터를 설치하여 제거할 수 있었다. 본 연구의 타당성을 PSIM 시뮬레이션에 의하여 확인하였으며 그 유용성을 입증하였다.

  • PDF

고역률 제어를 위한 단산 전압원 PWM 컨버터에 관한 연구 (A study of Single-phase Voltage Source PWM Converter for High Power Factor)

  • 류성식;손진근;정을기;김형원;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.362-365
    • /
    • 1999
  • In this paper, the method of reducing harmonics and correcting of power factor in single PWM converter associated with diode rectifier and boos converter is studied. The ac-dc converter in which the harmonic distortion in the input current is reduced using a third harmonic injected PWM is proposed. A lower switching power loss and easy configuration o control circuit are obtained by adopting discontinuous current mode. Simulation and experimental results of ac-dc converter with 5[KHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

경부고속철도 시험선구 고조파 예측에 관한 연구 (A study of the harmonics evaluation in the test track of Korea High Speed Rail)

  • 김길상;오광해;권삼영;이태형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.241-248
    • /
    • 1998
  • The purpose of this study is to evaluate the harmonics generated from Korea High Speed Rail's trainset and to analyze the effect on the KEPCO power system. This study focuses on the test track of the high speed rail and analyzes 154㎸ transmission line, scott transformer, autotransformer and 27,5㎸ line. The trainset is modeled as a harmonic source attached to the catenary line of the test track. Then, harmonic distortion is calculated. This distortion is compared with the KEPCO's regulations in relation to harmonic.

  • PDF