• Title/Summary/Keyword: Harmonic reduction system

Search Result 182, Processing Time 0.029 seconds

Rotordynamic Analysis of a Turbomolecular Pump (터보분자펌프의 회전체 동해석)

  • Han, Jeong-Sam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.764-765
    • /
    • 2011
  • In this paper, rotordynamic analyses of the Campbell diagram, critical speeds, and harmonic responses for a TMP rotor system are performed. Since the finite element model of the TMP rotor system has a very large number of degrees of freedom because of its complex geometry, and dynamic analyses for investigating the critical speeds, stability, and harmonic response are repeated for various design parameters, model order reduction (MOR) is necessary to reduce the computational cost. The Krylov-based model order reduction via moment matching significantly speeds up the rotordynamic analyses for the TMP rotor system.

  • PDF

A study of the Distribution system of Harmonic Analsys and reduction of EDSA (EDSA를 이용한 수용가 설비의 전력품질 분석)

  • Kim, Yong-Ha;Lee, Bum;Lee, Sung-Jun;Lee, Jae-Geol;Yeon, Jun-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.319-324
    • /
    • 2002
  • This paper describes analysis of power quality in distribute network system. EDSA is used for simulations to the teal model system. Harmonic load flow, harmonic frequency scan studies, distortion levels, and filter design method. Through this paper, minimized injected harmonic by computating the capacitor of optimal filter satisfied with IEEE Std-519 applying to distribute system are analysed through detailed simulation.

  • PDF

Study of Harmonic Influences in case of system-connections of Dispersed Substitute Energy-Generation Power Systems (분산전원의 계통연계시 고조파 영향 고찰)

  • Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.569-572
    • /
    • 2002
  • The reduction method of harmonic currents is very important, when harmonic influences of the systems connections of AC power lines with dispersed generations like solar energy and wind power generation etc, increase more and more. Which the influences of harmonic currents bring not only the drop of power quality but also many trouble occurrences of various systems. Recently, the necessity about application development of new substitute energy has gone up, and the development and practical use of dispersed power lines are proceeding now. Henceforth, a counterplan against harmonic influences must be devised for more practical use of new substitute energy. In this paper, we studied the harmonic influences and new devices for that connections and defined the calculating methods for hamonic currents of those systems.

  • PDF

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

A Proposal of Compact Passive Harmonic Filter for ac Motor Drive (고성능 콤팩트형 AC모터드라이브 고조파 필터 제안)

  • Park, Byung-Ju;Yoon, Dong-Chul;Oh, Jeong-Cheol;Bae, Byung-Yeol;Hwang, An-Il;Yoo, Hang-Kyu;Choi, Seok-Keun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.191-199
    • /
    • 2018
  • The harmonic reduction method of ac motor drive, ACL and DCL were commonly used, but the current distortion ratio was only 35%, thus the several different types of filters as BBHF(broad band harmonic filter), HHF(hybrid harmonic filter), NHHF(new hybrid harmonic filter) have been developed to satisfy the IEEE Std. 519 harmonic limitation. However, these filters had been limited marketability due to cost and size problems. This study suggests the methods to reduce cost and size of the harmonic filter including topologies, besides we discussed simulation results of the power system with regard to the implementation and performance of the filters.

Analysis of Impedance Performance for Condenser by Harmonic Current Source (고조파 전류원에 의한 콘덴서 임피던스 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Analysis of power quality using non-linear load at low voltage system (저압 시스템에서 비선형 부하의 사용에 따른 전력품질 해석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Sohn, Hong-Kwan;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.660-662
    • /
    • 2001
  • This paper describes the problems generated with the use of PWM ASDs with induction motors. The major effect of harmonic voltages and currents in induction motors is increased the heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency and developed the torque. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we set up simple load system and measured the voltage and current. Measurement results show that additional operation of induction motor at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

Frequency Analysis and Reduction of Electronic Noise in ESS (ESS의 전자 잡음 주파수 분석 및 제거)

  • Ahn, Bong Man;Han, Byoung Sung;Han, Un Ki;Lee, Young Kwan;An, Hyun Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.568-575
    • /
    • 2022
  • This paper is a study on frequency analysis and electronic noise reduction of energy storage system (ESS). We acquired 4 necessary data for about 2 minutes and 4 seconds using a sampling frequency of 10,000 Hz in ESS. Fast Fourier transform (FFT) was used for electronic noise analysis from the acquired data. As a result, it was confirmed that DC component, fundamental wave, second and higher harmonic component exist. For the attenuation of harmonics, low-pass filter (LPF) was applied. We confirmed that an attenuation of approximately 59.3% appears from the second harmonic. The presence of many harmonic components in the data of the ESS was expected to occur due to the insufficiency of optimization among the modules inside the ESS. Therefore, we propose that a national certification system for ESS should be introduced to settle down the issue properly.

High Speed Induction Motor Driving for using AM PWM (AM PWM을 이용한 고속 유도 전동기 구동)

  • 김민태;최재동;김영호;성세진;전칠환
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.380-383
    • /
    • 1998
  • Amplitude Modulation PWM Technique which has characteristics such as the switching loss and Harmonic distortion reduction is compared in this paper. And also Harmonic components only carrier frequencies. And as it is showed Harmonic components only carrier frequencies via simulation results. Am-pwm is applied to the inverter system of High-speed induction motor.

  • PDF

Adaptive Harmonic Control for DC Input Voltage Fluctuation of PWM Inverter (PWM인버터의 DC입력전달 맥동에 대한 고조파 적응제어)

  • 이윤종;임남혁
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.11
    • /
    • pp.896-904
    • /
    • 1989
  • PWM techniques which eliminate and reduce harmonics of output voltage in PWM Inverter driving System with fluctuating input volotage are described. First, harmonic factors are analyzed from harmonic equation of general PWM waveform and by examination of control possiblity of each factor, controllable factor is selected. Applying controllable factor to NPWM, PWM techniques using reference wave and carrier wave modulation are introduced. Actually, by the experiment applied with this strategy, the reduction of harmonics of output voltage is confirmed.

  • PDF