Initial-phase Sensitivity Analysis of Harmonic Measurements via Windowed DFT

  • Song, Shuping;Wang, Fuzong;Cheng, Guozhu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2014
  • When the windowed DFT algorithm is applied in harmonic measurements, the problem of initial-phase sensitivity will be encountered, this has an effect on harmonic amplitude accuracy. In this paper, the origin of initial-phase sensitivity is analyzed and the main factors that influence the level of initial-phase sensitivity are demonstrated. A method of reducing initial-phase sensitivity is proposed to increase the stability of harmonic measurements. We found that initial-phase sensitivity is determined by the side lobe peak level of the window functions when synchronous deviation is fixed. In addition, increasing the length of the time recorded can be used to remove initial-phase sensitivity. The correctness and validity of our conclusions have been confirmed through numerical results and field tests.

Harmonic Analysis of Reactor and Capacitor in Single-tuned Harmonic Filter Application

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.239-244
    • /
    • 2011
  • Industrial power distribution system includes many kinds of non-linear loads, which produce the harmonics during energy conversion transition. The single-tuned passive filter is widely used to absorb the harmonics and attenuate its undesirable effect in the distribution system. However, the passive filter might be severely stressed, and sometimes even damaged, due to the absorption of harmonics. There is voltage rise on the capacitor when the single-turned harmonic filter is applied. When the capacitor voltage rose above the allowable limit, the expected life of the capacitor will considerably deteriorate. On the other hand, the reactor can experience the spike voltage even if the voltage and current of the capacitor are within the allowable limit, and this accumulated voltage stress of the reactor causes its premature fault. In this paper, we analyzed and compared the harmonic voltage and current of the reactor and capacitor in a single-tuned harmonic filter through the EMTP software and verified them with the experimental results.

Winding Method of Transformer for Zero-Sequence and Negative-Sequence Harmonic Elimination (영상분 및 역상분 고조파 제거를 위한 변압기 결선방식)

  • Kim, Tae-Hoon;Park, Jun-Yeal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.896-902
    • /
    • 2014
  • As the various kinds of load who generate higher harmonics increases according as the power electronics technology develops, harmonic treatment standard is proposed by IEEE and IEC. Because establishment of harmonic reduction device is required for existent installment to satisfy harmonic treatment standard, the problem of investment charge and installation space increasing may be occurred. In order to solve these problems, a novel transformer connection method using principles of PCT and ZED is suggested.

A Study on the Transformer Capability containing Harmonic Load Currents (고조파를 포함하는 부하의 변압기 용량 산정에 관한 연구)

  • Kim, Kyung-Chul;Park, Sang-Young;Lee, Il-Moo;Paik, Seung-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.287-292
    • /
    • 2004
  • The increasing use of nonlinear loads has resulted in an increase in the harmonic content of the load current for power transformers. Transformers subject to harmonic currents have higher losses and need to be derated. This paper presents a simple method for determining the capability of transformers to supply harmonic load currents and shows that the application of capacitor banks with a series connected reactor and harmonic filters will geatly increase the capability of transformers. The EDSA program was used as a simulation tool for the carse study.

  • PDF

Analysis of Impedance Performance for Condenser by Harmonic Current Source (고조파 전류원에 의한 콘덴서 임피던스 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Carrier based SVPWM Method for Multi-Level System Considering Harmonic Distortion Factor

  • Lee, Yo-Han;Kim, Dong-Hyun;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.26-35
    • /
    • 2001
  • In most inverter/converter applications SVPWM method is a preferred approach since it shows good characteristics in linear modulation range and waveform quality. In this paper, we propose a new carrier based SVPWM method for multi-level system, First, we survey the conventional carrier based SVPWM method, and investigate the problem of the conventional one for the multi-level system with the focus on the switching frequency harmonic flux trajectories. Finally, we propose a new carrier based SVPWM method that can reduce harmonic distortion. Simulation and experimental results are given for verification of the proposed SVPWM method.

  • PDF

Oscillator with High Harmonic Suppression Using Split Quarterwave Microstrip Resonator

  • Cho, Ho-Yun;Go, Min-Ho;Jo, Yun-Hyun;Park, Hyo-Dal
    • ETRI Journal
    • /
    • v.33 no.1
    • /
    • pp.125-127
    • /
    • 2011
  • This letter presents a new type of resonator, namely, the split quarterwave microstrip resonator (SQMR), to improve the poor harmonic suppression and low Q-factors in conventional quarterwave microstrip resonators. An oscillator incorporating the proposed SQMR is designed, fabricated, and tested to demonstrate that, not only the second harmonic suppression, but also the phase noise of the oscillator can be improved. The oscillator with the SQMR shows improved second harmonic suppression of -74.59 dBc and phase noise figure of merit of -169.77 dBc/Hz at 1 MHz offset.

MULTI-HARMONIC MODELS FOR BUBBLE EVOLUTION IN THE RAYLEIGH-TAYLOR INSTABILITY

  • Choi, Sujin;Sohn, Sung-Ik
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.2
    • /
    • pp.663-673
    • /
    • 2017
  • We consider the multi-harmonic model for the bubble evolution in the Rayleigh-Taylor instability in two and three dimensions. We extend the multi-harmonic model in two dimensions to a high-order and present a new class of steady-state solutions of the bubble motion. The growth rate of the bubble is expressed by a continuous family of two free parameters. The critical point in the family of solutions is identified as a saddle point and is chosen as the physically significant solution. We also present the multi-harmonic model in the cylindrical geometry and find the steady-state solution of the axisymmetric bubble. Validity and limitation of the model are also discussed.

Multi Mode Harmonic Transform Coding for Speech and Music

  • Kim, Jonghark;Shin, Jae-Hyun;Lee, Insung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3E
    • /
    • pp.101-109
    • /
    • 2003
  • A multi-mode harmonic transform coding (MMHTC) for speech and music signals is proposed. Its structure is organized as a linear prediction model with an input of harmonic and transform-based excitation. The proposed coder also utilizes harmonic prediction and an improved quantizer of excitation signal. To efficiently quantize the excitation of music signals, the modulated lapped transform(MLT) is introduced. In other words, the coder combines both the time domain (linear prediction) and the frequency domain technique to achieve the best perceptual quality. The proposed coder showed better speech quality than that of the 8 kbps QCELP coder at a bit-rate of 4 kbps.

Harmonics Measurement of Evaluation of KJ Road Tunnel Installations (KJ 도로터널시설물의 고조파 실측 및 평가)

  • Wang, Yong-Peel;Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.87-93
    • /
    • 2011
  • Nonlinear loads including lighting fixtures generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probabilistic approach is the most commonly used method to solve time varying harmonics. In this paper the time varying harmonics of lighting loads are evaluated by international harmonic standards(IEC 61000-3-6).