• Title/Summary/Keyword: Hard X-ray

Search Result 206, Processing Time 0.021 seconds

Survey on Radiographic Works in Hospitals and Clinics (병(病)-의원(醫院)의 X선촬영업무(線撮影業務)에 관한 실태조사(實態調査))

  • Choi, Song-Hak;Jeon, Man-Jin;Park, Sung-Ock;Lim, Han-Young;Kim, Keon-Chung;Huh, Joon;Choi, Jong-Woon
    • Journal of radiological science and technology
    • /
    • v.7 no.1
    • /
    • pp.3-11
    • /
    • 1984
  • The major findings of this investigation on radiographic works in 125 medical institutions around Seoul and Kyung-Ki area, from March 1983 to February 1984, are summarized as follows. 1. The number of references provided on radiographic techniques were 3 to 5 in general hospitals (52.1%), in hospitals (58.5%), and clinics (44.5%), and only the 10.4% of general hospitals had 11 or more. 2. The relatively high percentages of 75.0% of general hospitals and 68.3% of hospitals have established the standardized radiographic methods for regions examined, but most clinics (61.1%) have not. 3. As a log system for the radiographic request, the method of "routine study, or all the x-ray examinations are marked as 0 on a printed form" was most commonly used by general hospitals (62.5%) and hospitals (51.2%), and "the doctors employ their own methods" in most clinics (44.6%). 4. In the 85.4% of general hospitals, the 68.3% of hospitals and the 38.9% of clinics, the data such as diagnosis, clinic history, purpose of x-ray examination were recorded on a radiographic request at all times, or at least in part. 5. On a scale of hardness and easiness of order of doctors, the greatest response was "fairly easy to understand", and the 37.5% of general hospitals responded as "sometimes hard". 6. In determining the standards for radiographic factors, the general hospitals (62.5%) and hospitals (65.9%) adapted mostly "a departmental check list", and the clinics (61.1%) used mainly "a personal decision". 7. In using the immobilizing devices, angligner, and radiographic accessories, the Percentages were high in general hospitals and hospitals on the one hand, and were low in clinics on the other. 8. A consideration with regard to the devices for an improvement of examination of the same patients was totally ignored by the 50.0% of clinics, the 26.8% of hospitals and the 20.8% of general hospitals. 9. The causes of re-examination were due largely to patients (33.6%), and followed proportionately by incorrect exposure (22.8%), errors in positioning (22.0%), film processing faults (9.2%), conditions of x-ray equipments (8.8%), and quality of x-ray films (3.6%). 10. The conference on radiography was conducted regularly or irregularly by the 87.5% of general hospitals, the 56.1% of hospitals, and the 27.7% of clinics, and the meeting was proceeded only by radiologic technologists.

  • PDF

Daily localization of partial breast irradiation patients with three-dimensional ultrasound imaging

  • Sayan, Mutlay;Vergalasova, Irina;Hard, Daphne;Wrigth, Heather;Archambault, Jessica;Gagne, Havaleh;Nelson, Carl;Heimann, Ruth
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.259-264
    • /
    • 2019
  • Purpose: Accurate localization of the lumpectomy cavity during accelerated partial breast radiation (APBR) is essential for daily setup to ensure the prescribed dose encompasses the target and avoids unnecessary irradiation to surrounding normal tissues. Three-dimensional ultrasound (3D-US) allows direct visualization of the lumpectomy cavity without additional radiation exposure. The purpose of this study was to evaluate the feasibility of 3D-US in daily target localization for APBR. Materials and methods: Forty-seven patients with stage I breast cancer who underwent breast conserving surgery were treated with a 2-week course of APBR. Patients with visible lumpectomy cavities on high quality 3D-US images were included in this analysis. Prior to each treatment, X-ray and 3D-US images were acquired and compared to images from simulation to confirm accurate position and determine shifts. Volume change of the lumpectomy cavity was determined daily with 3D-US. Results: A total of 118 images of each modality from 12 eligible patients were analyzed. The average change in cavity volume was 7.8% (range, -24.1% to 14.4%) on 3D-US from simulation to the end-of-treatment. Based on 3D-US, significantly larger shifts were necessary compared to portal films in all three dimensions: anterior/posterior (p = 7E-11), left/right (p = 0.002), and superior/inferior (p = 0.004). Conclusion: Given that the lumpectomy cavity is not directly visible via X-ray images, accurate positioning may not be fully achieved by X-ray images. Therefore, when the lumpectomy cavity is visible on US, 3D-US can be considered as an alternative to X-ray imaging during daily positioning for selected patients treated with APBR, thus avoiding additional exposure to ionizing radiation.

Synthesis of LiCoO2 Powders using Recycled Cobalt Precursors from Waste WC-Co Hard Metal (폐 WC-Co계 초경합금에서 추출된 코발트 재생 원료를 이용한 LiCoO2 입자 합성 연구)

  • Yang, Hee-Seung;Pee, Jae-Hwan;Kim, Yoo-Jin
    • Journal of Powder Materials
    • /
    • v.18 no.3
    • /
    • pp.277-282
    • /
    • 2011
  • [ $LiCoO_2$ ] a cathode material for lithium rechargeable batteries, was prepared using recycled $Co_3O_4$. First, the cobalt hydroxide powders were separated from waste WC-Co hard metal with acid-base chemical treatment, and then the impurities were eliminated by centrifuge method. Subsequently, $Co_3O_4$ powders were prepared by thermal treatment of resulting $Co(OH)_2$. By adding a certain amount of $Li_2CO_3$ and $LiOH{\cdot}H_2O$, the $LiCoO_2$ was obtained by sintering for 10 h in air at $800^{\circ}C$. The synthesized $LiCoO_2$ particles were characterized by X-ray diffraction (XRD) and Scanning Electron Microscope (SEM) analysis.

The ability of panoramic radiography in assessing maxillary sinus inflammatory diseases

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.38 no.4
    • /
    • pp.209-213
    • /
    • 2008
  • Purpose : To evaluate the relative diagnostic accuracy of panoramic radiography and Water's projection in maxillary sinus inflammatory diseases by comparing the radiodensities of the images with those of CT. Materials and Methods : Panoramic radiographs, Waters' projection, and CT images from 55 subjects (11O sinuses) were included in this retrospective study. The radiodensity of each maxillary sinus in panoramic radiography was recorded separately as upper and lower divided horizontally by hard palate. In Waters' projection, the overall sinus radiodensity was recorded. The CT images were considered as gold standard. Results : In panoramic radiography, 83 sinuses had same upper and lower radiodensity and 72 of these were consistent with those of CT, 26 sinuses had different upper and lower radiodensity and 15 of these, upper radiodensity was consistent with CT, the remaining 11, lower radiodensity was consistent with CT. One sinus had upper radiolucency with lower radiopacity and both were consistent with those of CT. Altogether 73 (66.4%) among 110 sinuses in panoramic radiography showed full agreement with CT, 26 (23.6%) showed partial agreement with CT. 9 sinuses had no lower image under the hard palate in panoramic radiography due to the smaller size of sinus. In Waters' projection, the radiodensity of 105 sinuses (95.5%) were consistent with that of CT. Conclusion : The panoramic radiography showed 90.0% of the sinus conditions fully or partially which may appear less accurate than that of Water's view (95.5%) but with more detailed information of the inferior part of sinuses. (Korean J Oral Maxillofac Radiol 2008; 38 : 209-13)

  • PDF

Surface Properties of ACL Thin Films Depending on Process Conditions (공정 조건에 따른 비정질 탄소막 표면 물성분석)

  • Kim, Kwang Pyo;Choi, Jeong Eun;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.44-47
    • /
    • 2019
  • Amorphous carbon layer (ACL) is actively used as an etch mask. Recent advances in patterning ACL requires the next level of durability of hard mask in high aspect ratio etch in near future semiconductor manufacturing, and it is worthwhile to know the surface property of ACL thin film to enhance the property of etch hard mask. In this research, ACL are deposited by 6 inch plasma enhanced chemical vapor deposition system with $C_3H_6$ and $N_2$ gas mixture. Surface properties of deposited ACL are investigated depending on gas flow, pressure, RF power. Fourier transform infrared is used for the analysis of surface chemistry, and X-ray photoemission spectra is used for the structural analysis with the consideration of the contents of $sp^2$ and $sp^3$ through fitting of C1s. Also mechanical properties of deposited ACL are measured in order to evaluate hardness.

Effects of Sand Blasting on TiAlN Coating on WC Hard Metal Alloy Tip (WC위 TiAlN 코팅층에 미치는 Sand Blasting 처리의 영향)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.37 no.2
    • /
    • pp.54-61
    • /
    • 2021
  • The effect of the sand blasting before TiAlN coating in the manufacture of WC hard metal alloy tips have been studied. For four different tips, according to the status of processing of the sand blasting and the coating, residual stress measurement by X-ray diffraction and several tests for mechanical properties have been conducted. The results suggest that there was no difference in static mechanical properties, such as hardness, surface roughness and elastic modulus, between two coatings. Furthermore, compressive residual stress was generated equally on their surfaces. Additionally, the compressive residual stress in substrate WC was found to increase greatly when subjected to sand blasting treatment. However, the compressive residual stress decrease after coating regardless of sand blasting treatment. Nevertheless, it is confirmed that the compressive residual stress generated in the coating after sand blasting is less than that in the non-sandblasting coating. This was attributed to the plastic deformation occurring in the WC substrate during coating after sand blasting. In contrast to the scratch test results, sand blasting was assumed to have a negative effect on the adhesion between the coating and substrate. This is because there is a high possibility of microcracks due to plastic deformation in the WC substrate under the coating after sand blasting.

The relation of structural transition, thermal and electrical stability deintercalation of Li- CICs(II) : For Li-EaGDICs and Li-EGDICs (Li-CICs의 Deintercalation에 따른 구조변이와 열적, 전기적 안정성과의 관계(II) : Li-EaGDICs와 Li-EGDICs에 관하여)

  • Oh, Won-Chun;Park, Chung-Oh;Back, Dae-Jin;Ko, Young-Shin
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.43-51
    • /
    • 1996
  • We have discussed on the deintercalation process of Li-EaGICs and Li-EGICs synthesized under pressure and temperature by spontaneous oxidation reaction of those compounds based on the results of X-ray diffraction, thermal analysis and electrical specific resistivity analysis. According to the results of the X-ray analysis for the intercalation process, we have found that the stage 1 for Li-EaGICs and Li-EGICs were not completly formed, but their lower stages were formed mainly. And from this results of the deintercalation process, we have found that the deintercalation process did not occur any more after 4 weeks, and the Li-EGDICs have more residual lithium metals than LiEaGDICs between the graphite interlayers. According to the thermal decomposition analysis, Li-two compounds had included very hard exothermic reaction. And we have found that these compounds did not occrurred deintercalation reaction above $400^{\circ}C$. According to the results of the electrical specific resistivity measurements, Li-EGDICs have relatively lower electrical specific resistivity than Li-EaGDICs, and Li-EaGDICs showed a formation of the ideal curve. From these results, we can suggest that Li-EaGDICs have a better properties as an anode material secondary than Li-EGICs.

  • PDF

The Effect of Additional Elements on the Tailored Magnetic Properties of Electrochemically Prepared CoPtP-X Alloys (전기화학적으로 제조한 CoPtP-X합금의 첨가제 효과에 따른 맞춤형 자기적 성질)

  • Park, H.D.;Lee, K.H.;Kim, G.H.;Jeung, W.Y.;Choi, D.H.;Lee, W.Y.
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.2
    • /
    • pp.94-98
    • /
    • 2005
  • Coptp films with the additive elements (X=Fe, Mn) of varying concentrations were prepared by in-situ electrodeposition, to tailor their magnetic properties. Alloys of CoPtP-X (X=Fe, Mn) were synthesized by changing the solution concentrations of Fe and Mn for electrodeposition. In the electrodeposited CoFePtP alloys, preferred orientation of the electrodeposited films changed from hexagonal (001) to (100) direction with increasing iron contents as revealed by X-ray diffraction, and these films exhibited various magnetic properties ranging from a typical hard magnetic to a soft magnetic property in accordance with microstructural variations. In the case of Mn addition, excellent hard magnetic property was observed at a specific Mn concentration of 0.0126 M in the electrolyte, with the coercivity of 4630 Oe and squareness of 0.856 and this was attributed to the fact that magnetization easy-axis (hexagonal c-axis) coincides with the preferred growth orientation of the film confirmed by transmission electron microscopy.

Preparation and Characterization of Spherical Carbon Composite for Use as Anode Material for Lithium Ion Batteries

  • Ahn, Byoung-Hoon;Lee, Sung-Man
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1331-1335
    • /
    • 2010
  • A novel spherical carbon composite material, in which nanosized disordered carbons are dispersed in a soft carbon matrix, has been prepared and investigated for use as a potential anode material for lithium ion batteries. Disordered carbons were synthesized by ball milling natural graphite in air. The composite was prepared by mixing the ball-milled graphite with petroleum pitch powder, pelletizing the mixture, and pyrolyzing the pellets at $1200^{\circ}C$ in an argon flow. The ballmilled graphite consists of distorted nanocrystallites and amorphous phases. In the composite particle, nanosized flakes are uniformly distributed in a soft carbon matrix, as revealed by X-ray diffractometer (XRD) and transmission electron microscopy (TEM) experiments. The composite is compatible with a pure propylene carbonate (PC) electrolyte and shows high rate capability and excellent cycling performance. The electrochemical properties are comparable to those of hard carbon.

Etching Characteristics of Polyimide Film as Interlayer Dielectric Using Inductively Coupled ($O_2/CF_4$)Plasma ($O_2/CF_4$ 유도결합 플라즈마를 이용한 Polyimide 박막의 식각 특성)

  • Kang, Pil-Seung;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1509-1511
    • /
    • 2001
  • In this study, etching characteristics of polyimide(Pl) film with $O_2/CF_4$ gas mixing ratio was studied using inductively coupled plasma (ICP). The etch rate and selectivity were evaluated to chamber pressure and gas mixing ratio. High etch rate (over 8000$\AA$/min) and vertical profile were acquired in $CF_4$/($CF_4+O_2$) of 0.2. The selectivities of polyimide to PR and polyimide to $SiO_2$ were 1.15, 5.85, respectively. The profiles of polyimide film etched in $CF_4/O_2$ were measured by a scanning electron microscope (SEM) with using an aluminum hard mask pattern. The chemical states on the polyimide film surface were measured by x-ray photoelectron spectroscopy (XPS).

  • PDF