• Title/Summary/Keyword: Haptic device

Search Result 229, Processing Time 0.025 seconds

A Study of Controller's Output Characteristics for Hatic Interface System (촉각시스템용 제어기의 출력특성연구)

  • Kim Y.S.;Kim A.H.;Bae C.;Kang W,C.;Kim Y.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.410-414
    • /
    • 2003
  • In this paper, the virtual-reality system is tried to developed, which controls not only the sense of sight and hearing but also the sense of touch, In order to develope the sense of touch in this study, the stable tactual transaction-system, based on summing up the basic algorithm and theory, is embodied. The hardware of this system consists of the 6DOF haptic interface, a controller and a driver In the case of the software, the proxy algorithm is applied for the force-transaction and the mopping algorithm is used for graphic transaction. In addition to this, the imaginary-device driver is utilized for controlling the system and manager-class is also included in this system to manage the position-change and the like. Consequently, the proxy algorithm Is applied, which makes the system possible to be more stable and prompt with and imaginary object. Moreover, the impulse-algorithm is applied to work out a problem which the tactual transaction-period is different from the graphic transaction-period.

  • PDF

Development and Effect Analysis of Experiential Electrical Safety Education System Based on Virtual Reality (가상현실 기반 체험형 전기안전 교육 시스템의 개발 및 효과 분석)

  • Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1767-1773
    • /
    • 2016
  • Every year, lives are lost due to electrical safety accidents that could have been prevented with proper education and awareness of electrical safety. To prevent such accidents, experiential education is more effective than indoctrination education. This paper describes the electrical safety education system based on virtual reality (VR) and evaluates effect of the proposed system. Users operated the experiential electrical safety education system, and they were provided electrical stimulation in an electric shock experience using a haptic device. Appropriate stimulation values were calculated according to age (children vs. adults) and gender through experiment. The scenario in which participants experience electrical safety in the home environment was structured, and related educational contents was produced. A total of 68 healthy elementary students evaluated the educational effect of the system. The results showed that the educational effect and the sustainability of effect of the proposed system are superior to those of existing multimedia learning methods. By implementing electrical safety education stimulating the senses of human, the learning effect was promoted and this experiential education would be able to prevent electrical accidents.

Mixed-Reality Based Situation Training System for the Developmental Disabled (발달장애인을 위한 혼합현실 기반 상황훈련 시스템)

  • Kim, Sung-Jin;Kim, Tae-Young;Lim, Chul-Soo
    • Journal of the Korea Computer Graphics Society
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • This paper presents a design of a situation training system supporting mixed-reality for the developmental disabled. The training scenario is developed for the disabled to improve the sense of sight and perception. The user sticks a virtual pin into a hole in the working board according to the direction and the appropriate feedback is delivered based on the FSM(Finite State Machine). In order to improve the reality and the training effect, the user's hand is inserted in the virtual training environments and the tactile sensation is provided using the haptic device.

  • PDF

Teleloperation of Field Mobile Manipulator with Wearable Haptic-based Multi-Modal User Interface and Its Application to Explosive Ordnance Disposal

  • Ryu Dongseok;Hwang Chang-Soon;Kang Sungchul;Kim Munsang;Song Jae-Bok
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1864-1874
    • /
    • 2005
  • This paper describes a wearable multi-modal user interface design and its implementation for a teleoperated field robot system. Recently some teleoperated field robots are employed for hazard environment applications (e.g. rescue, explosive ordnance disposal, security). To complete these missions in outdoor environment, the robot system must have appropriate functions, accuracy and reliability. However, the more functions it has, the more difficulties occur in operation of the functions. To cope up with this problem, an effective user interface should be developed. Furthermore, the user interface is needed to be wearable for portability and prompt action. This research starts at the question: how to teleoperate the complicated slave robot easily. The main challenge is to make a simple and intuitive user interface with a wearable shape and size. This research provides multi-modalities such as visual, auditory and haptic sense. It enables an operator to control every functions of a field robot more intuitively. As a result, an EOD (explosive ordnance disposal) demonstration is conducted to verify the validity of the proposed wearable multi-modal user interface.

A Study on Technique of Navigation with Power-Reflected of the Walker in the Indoor Environment

  • Kim, Min-Sik;Kwon, Hyouk-Gil;Ryu, Je-Goon;Shim, Hyeon-Min;Lee, Eung-Hyuk;Shim, Jea-Hong;Lee, Sang-Moo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.957-962
    • /
    • 2005
  • Today, the elderly is increasing gradually in the Republic of Korea society and this problem will be more serious in the near future. Therefore, engineering support for aged people is required. We are establishing a new field of healthcare engineering for elderly people and aiming to support for aged people and disabled people using adaptive control and instrument technology. In this paper, the goal is to implement the shared control of a robot mobility aid for the elderly. As using this type of assistive technology to be useful by its intended user community, it supports elderly people and handicapped people to live independently in their private homes. The interface transforms the force applied by the user into the robot's motion. Devices like buttons, joysticks, and levers already exist for relaying user input; however, they require hand displacement that would loosen or otherwise release the user's hold. Such interfaces make operation very difficult and potentially unsafe. Therefore, we propose a shared control system. It's safe more than joysticks and buttons. The shared control is a means of registering the user's intention through physical interaction. It's an important component in the development of robotic elderly assistant. The concept of shared control describes a system which is two or more independent control systems. We are using that the three component blocks consist of pressure sensor (flexible force sensor), circuit of measurement and transfer function. Experimental trials of this paper have been tested at the indoor environment. The robot is able to know the user intended direction through haptic device were logged along with the robot's force sensor.

  • PDF

Surveyed restoration and RPD framework design utilizing electronic surveying (전자 서베잉을 이용한 서베이드 금관과 국소의치 프레임워크 디자인)

  • Hong, Yong-Shin;Park, Eun-Jin;Kim, Seong-Kyun;Koak, Jai-Young;Heo, Seong-Joo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.354-361
    • /
    • 2011
  • There are still many limitations on fabricating dentures using digital method while computerized production of fixed prostheses utilizing intraoral scanner and CAD/CAM technology has propagated rapidly. Recently the digital solution of fabricating removable partial denture by applying haptic input device, electronic surveying, and rapid prototyping was introduced. In this case presentation, five patients were treated with surveyed crown and removable partial dentures by this digital solution. Fit of dentures was excellent except for one case which showed morphological difference between the actual teeth and that of master cast by the erroneous impression process. There also was not any problem of stability and retention after adaptation in the clinical setting.

Design of a Novel Gait Rehabilitation Robot with Upper and Lower Limbs Connections (상하지 연동된 새로운 보행재활 로봇의 설계)

  • Yoon, Jung-Won;Novandy, Bondhan;Christi, Christi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.7
    • /
    • pp.672-678
    • /
    • 2008
  • This paper proposes a new rehabilitation robot with upper and lower limb connections for gait training. As humans change a walking speed, their nervous systems adapt muscle activation patterns to modify arm swing for the appropriate frequency. By analyzing this property, we can find a relation between arm swinging and lower limb motions. Thus, the lower limb motion can be controlled by the arm swing for walking speed adaptation according to a patent's intension. This paper deals with the design aspects of the suggested gait rehabilitation robot, including a trajectory planning and a control strategy. The suggested robot is mainly composed of upper limb and lower limb devices, a body support system. The lower limb device consists of a slider device and two 2-dof footpads to allow walking training at uneven and various terrains. The upper limb device consists of an arm swing handle and switches to use as a user input device for walking. The body support system will partially support a patient's weight to allow the upper limb motions. Finally, we showed simulation results for the designed trajectory and controller using a dynamic simulation tool.

Auto Qualification Test Guide of Control Loading System for Flight Simulation Training Device (모의비행훈련장치용 조종반력시스템의 자동-QTG 구현)

  • Chun-Han Hong;Won-Seok Shin;Sang-Jin Jung;Byeong Soo Kim
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.32 no.2
    • /
    • pp.11-19
    • /
    • 2024
  • Flight simulators are crucial devices for aircraft piloting training and simulation, requiring regular inspections to maintain performance and operational quality. This study explores the development of an automated inspection system for flight simulators to automate quality inspections of control loading systems (CLS). While quality inspection of the control loading system (CLS) is essential for flight simulators, manual inspections are common practice. To address this, we developed an Auto Qualification Test Guide (Auto QTG) using artificial control logic and sensor data and applied it to the militarily simulator. Experimental results demonstrate that Auto QTG successfully automates quality inspections of CLS, enhancing accuracy and efficiency. This automated inspection system is expected to contribute to improving the operation and maintenance of flight simulators.

Development of a Wearable Vibrotactile Display Device (착용 가능한 진동촉감 제시 장치 개발)

  • Seo, Chang-Hoon;Kim, Hyun-Ho;Lee, Jun-Hun;Lee, Beom-Chan;Ryu, Je-Ha
    • Journal of the HCI Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 2006
  • Tactile displays can provide useful information without disturbing others and are particularly useful for people with visual or auditory impairments. They can also complement other displays. In this paper, we present a new vibrotactile display device for wearable, mobile, and ubiquitous computing environments. The proposed vibrotactile device has a $5{\times}5$ array configuration for displaying complex information such as letters, numbers, and haptic patterns as well as simple directional ques and situation awareness alarms. Commercially available coin-type vibration motors are embedded vertically in flexible mounting pads in order to best localize vibrations on the skin. An embedded microprocessor controls the motors sequentially with an advanced tracing mode to increase recognition rate. User studies with the vibrotactile device on the top of the foot show 86.7% recognition rate for alphabet characters after some training. In addition, applying vibrotactile device to driving situation shows 83.9% recognition rate. We also propose some potentially useful application scenarios including Caller Identification for mobile phones and Navigation Aids for GPS systems while driving.

  • PDF

EMS based Force Feedback Methodology through Major Muscle Group Activation (대표근육 자극을 통한 EMS 기반 역감 제어방법론 제안)

  • Kim, Hyo-Min;Kwon, Jae-Sung;Oh, Yong-Hwan;Yang, Woo-Sung
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.3
    • /
    • pp.270-278
    • /
    • 2017
  • The electrical muscle stimulator (EMS) based human machine interface (HMI) free to mechanical constraint and muscle fatigue problems are proposed for force feedback in a virtual reality. The device was designed to provide force feedback up to 4.8 N and 2.6 N each to the thumb and forefingers. The main objective of the HMI is to make unnecessary mechanical structures to attach on the hand or fingers. It employs custom EMSs and an interface arranged in the forearm. In this work, major muscle groups such as extensor pollicis brevis (EPB), extensor indicis proprius (EIP), flexor pollicis longus (FPL) and flexor digitorum profundus (FDP) are selected for efficient force feedback and controlled individually. For this, a human muscular-skeletal analysis was performed and verified. The validity of the proposed multi-channel EMS based HMI was evaluated thorough various experiments with ten human subjects, interacting with a virtual environment.