• Title/Summary/Keyword: Hand-held

Search Result 453, Processing Time 0.029 seconds

A Development of Image Transfer Remote Maintenance Monitoring System for Hand Held Device (휴대용 화상전송 원격정비 감시시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.276-284
    • /
    • 2009
  • In this paper, we develop the image transfer remote maintenance monitoring system for hand held device which can compensate defects of human mistake. The human mistakes always happen when the worker communicate information each other to check and maintenance the equipment of the power plant under bad circumstance such as small place and long distance in power plant. A worker couldn't converse with other when in noisy place like Power plant. So, we make some hand device for handy size and able to converse in noisy place. The developed system can have improvement of productivity through increasing plant operation time. And developed system is composed of advanced H/W(hard ware) system and S/W(soft ware)system. The H/W system consist of media server unit, communication equipment with hand held device, portable camera, mike and head set. The advanced s/w system consist of data base system, client pc(personal computer) real time monitoring system which has server GUI(graphic user interface) program, wireless monitoring program and wire ethernet communication program. The client GUI program is composed of total solution program as pc camera program, and phonetic conversation program etc.. We analyzed the required items and investigated applicable part in the image transfer remote maintenance monitoring system with hand held device. Also we investigated linkage of communication protocol for developed prototype, developed software tool of two-way communication and realtime recording skill of voice with image. We confirmed the efficiency by the field test in preventive maintenance of plant power.

The Visual Aesthetics of Drone Shot and Hand-held Shot based on the Representation of Place and Space : focusing on World Travel' Peninsula de Yucatán' Episode (장소와 공간의 재현적 관점에서 본 드론 쇼트와 핸드헬드 쇼트의 영상 미학 : <세계테마기행> '유카탄 반도'편을 중심으로)

  • Ryu, Jae-Hyung
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.3
    • /
    • pp.251-265
    • /
    • 2020
  • The Drone shot is moving images captured by a remotely controlled unmanned aerial vehicle, takes usually bird's eye view. The hand-held shot is moving images recorded by literal handheld shooting which is specialized to on-the-spot filming. It takes a walker's viewpoint through vivid realism of its self-reflexive camera movements. The purpose of this study is to analyze comparatively aesthetic functions of the drone shot and the hand-held shot. For this, the study understood Certeau's concepts of 'place' and 'space,' chose World Travel 'Peninsula de Yucatan' episode as a research object, and analytically applied two concepts to the scenes clearly presenting two shots' aesthetic characteristics. As a result, the drone shot took the authoritative viewpoint providing the general information and atmosphere as it overlooked the city with silent movements removing the self-reflexivity. This aesthetic function was reinforced the narration and subtitles mediating prior-knowledge about proper rules and orders of the place. The drone shot tended to project the location as a place. Conversely, the hand-held shot practically experienced the space with free walking which is free from rules and orders inherent in the city. The aesthetics of hand-held images represented the tactic resisting against the strategy of a subject of will and power in that the hand-held shot practiced anthropological walking by means of noticing everyday lives of the small town and countryside than main tourist attraction. In opposition to the drone shot, the hand-held shot tended to reflect the location as a space.

Effect of the amount of battery charge on tube voltage in different hand-held dental x-ray systems

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.42 no.1
    • /
    • pp.1-4
    • /
    • 2012
  • Purpose : Hand-held dental x-ray system is a self contained x-ray machine designed to perform intraoral radiography with one or two hands. The issue about its usage as general dental radiography is still in dispute. The aim of the present study was to assess the relationship between the amount of battery charge and the tube voltage in different handheld dental x-ray systems. Materials and Methods : Seven hand-held dental x-ray units were used for the study. Tube voltage was measured with Unfors ThinX RAD (Unfors Instruments AB, Billdal, Sweden) for 3 consecutive exposures at the different amount of battery charge of each unit. The average and the deviation percentage of measured kV from indicated kV of each unit were calculated. Results : Tube voltage of only 1 unit was 70 kV (indicated by manufacturer) and those of the others were 60 kV. Tube voltage deviation percentage from the indicated kV at the fully charged battery was from 2.5% to -5.5% and from -0.8% to -10.0% at the lowest charged battery. Conclusion : Tube voltages of all units decreased as the residual amount of the battery charge decreased. It is suggested that the performance test for hand-held x-ray system should be performed for the minimum residual charged battery as well as the full charged one. Persistent battery charging is suggested to maintain the proper tube voltage of the hand-held portable x-ray system.

HAND-HELD NIR SPECTROMETRY : STATUS, TRENDS AND FUTURISTIC PROSPECTS

  • McClure, W.F.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1051-1051
    • /
    • 2001
  • In 1989, at the 2nd ICNIRS Meeting in Tsukuba, I projected certain directions for NIR technology would take in the future. Among those projections were: (1) An inrush of companies producing FT-NIR instruments. (2) Hybrid NIR Systems (3) Hand-held NIR Technology. All three thrusts have resulted in numerous commercial offerings over the last 12 years Hand-held technology for all fields is growing at an astonishing rate. To date, NIR work at North Carolina State University has produced four (4) hand-held NIR units for: (1) Nicotine and Moisture in tobacco, (2) Vanillin and Moisture in Vanilla Beans, (3) Protein, Moisture and Nitrogen in plant tissue, (4) Chlorophyll and Moisture in Growing Plants: A NIR Spectrometer for Developing Countries. This paper will discuss these developments, including design and performance data.

  • PDF

Ground Penetrating Radar based Hand-held Landmine Detection System using Frequency Shifting Filtering (주파수 이동 필터링을 적용한 지면 투과 레이더 기반 휴대용 지뢰 탐지 시스템)

  • Hahm, Jong-Hun;Kim, Min Ju;Heo, Eun Doo;Kim, Seong-Dae;Kim, Dong Hyun;Choi, Soon-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.74-84
    • /
    • 2017
  • Since a soldier manages a hand-held landmine detector by hands, it is necessary to develop a system that can detect the target quickly and accurately. However, the hand-held landmine detector used in Korea has a problem that it can only detect the metal mines. Therefore, it is important to solve the problem and to develop a hand-held landmine detection system suitable for the Korean environment. In this paper, we propose a hand-held landmine detection system suitable for the Korean environment using ground penetrating radar. The proposed system uses depth compensation, matched filtering, and frequency shifting filtering for preprocessing. Then, in the detection step, the system detects the target using the edge ratio. In order to evaluate the proposed system, we buried landmines in sandy loam which is most of the soil in Korea and obtained a set of ground penetrating radar data by using a hand-held landmine detector. By using the obtained data, we carried out some experiments on the size and position of the patch and the shifting frequency to find the optimal parameter values and measured the detection performance using the optimized values. Experimental results show that the proposed preprocessing algorithms are suitable for detecting all landmines at low false alarm rate and the performance of the proposed system is superior to that of previous works.

A Vibrotactile Display for Hand-held Devices and Its Preferable Pattern Generation Method (모바일 기기를 위한 진동촉각 디스플레이와 선호하는 패턴 생성방법)

  • Yang, Gi-Hun;Jin, Yeonsub;Kang, Sungchul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.8
    • /
    • pp.795-800
    • /
    • 2014
  • In this paper, a vibrotactile pad system, T-mobile, is developed to provide vibrotactile cues for hand-held devices. A grooved and slim design is adapted to the back-side plane of the T-mobile, and the contact part consists of 12 vibrotactile panels which can operate independently and separately. To be isolated among vibrotactile actuators, the surface of the cover is divided into several pieces. Each vibrating module consists of a linear resonant actuator, a section of covering surface, and a vibration isolator. In order to provide spatial and directional information, sensory saltation and phantom sensation are applied to the T-mobile. To evaluate the developed device, two experiments were conducted to test whether directional information and spatial information can be successfully displayed by the device. Additionally, in order to find optimal stimulation by sensory saltation, an empirical test was conducted. As a result, spatial and directional information would be useful for displaying intuitive information for hand-held devices with vibrotactile feedback and reasonable near-optimal value for sensory saltation was obtained.

Optical Coherence Tomography Applications for Dental Diagnostic Imaging: Prototype System Performance and Preclinical Trial

  • Eun Seo Choi;Won-Jin Yi;Chang-Seok Kim;Woosub Song;Byeong-il Lee
    • Current Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.283-296
    • /
    • 2023
  • An intraoral spectral domain optical coherence tomography (SD-OCT) system has been developed, using a custom-built hand-held scanner and spectrometer. The hand-held OCT probe, based on a microelectromechanical systems scanner and a self-built miniaturized drive circuit, had a field of view sufficient for dental diagnosis. The spectrometer using a fabricated f-theta lens provided the image depth required for dental diagnosis. The axial and transverse resolutions of the OCT system in air were 7.5 ㎛ and 12 ㎛ respectively. The hand-held probe could scan an area of 10 × 10 mm2, and the spectrometer could image along a depth of 2.5 mm. To verify the utility of the developed OCT system, OCT images of tooth hard and soft tissues were acquired, and a user-interface program for diagnosis was developed. Early caries and microcracks that were difficult to diagnose with existing methods could be found, and the state of restoration could be observed. Measuring the depth of the gingival sulcus, distinguishing subgingival calculus, and detecting an implant under the gingiva suggested the possibility of the SD-OCT system as a diagnostic for dental soft tissues. Through the presented OCT images, the capability of the developed SD-OCT system for dental diagnosis was demonstrated.

Design and Implementation of Hand-Held Inspection Device for High Performance Mobile TFT LCD/OLED Module (고성능 모바일 TFT LCD/OLED 모듈을 위한 헨드헬드 검사장비 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.630-640
    • /
    • 2009
  • The thesis suggests hand-held equipment to overhaul for mobile TFT LCD/OLED module of high-performance. The established module equipment to overhaul could distinguish outputting video data to module for distinguishing flicker, but it is impossible with low system. In this thesis, supporting system could check the various supplement functions from bringing equipment to overhaul without changing design of FPGA or H/W the module various size for equipment to overhaul for module of high-performance coincidently. The system includes hand-held equipment to overhaul, test software embedded and software a base personal computer and have designed to output, save, and certify all contents of module test of hand-held equipment to overhaul to interface universal serial bus. Setting up 9 items that represent for efficient verification of the proposed system have been possible confirmation with TFT LCD/OLED module of high-performance, establishment scan time, creation gamma, changing register, supporting interface, and multi inch modules.

Development of Hand-held OCT probe for Ophthalmic Imaging (안구 영상을 위한 OCT용 손잡이 형 프로브의 개발)

  • Cho, Nam-Hyun;Jung, Woong-Gyu;Jung, Un-Sang;Sephen, A.Boppart;Shim, Jae-Hoon;Kim, Jee-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • We have developed a hand-held probe for an ophthalmic OCT system. The hand-held probe for imaging was designed to be compact and portable. The cornea and retinal images were acquired by replacing the objective lens at the front of the probe. To verify the performance of the hand-held OCT probe, we acquired two dimensional OCT image of the rat eye in vivo and reconstructed three dimensional rat eye rendering images. In vivo 3D OCT images were showed distinct structural information in the posterior and anterior chamber with minimal motion artifacts. Thereby, OCT imaging speed is suitable for an dynamic in vivo experiment.

Pulse shape discrimination using a stilbene scintillator array coupled to a large-area SiPM array for hand-held dual particle imager applications

  • Jihwan Boo;Mark D. Hammig;Manhee Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.648-654
    • /
    • 2023
  • A dual-particle imager (DPI) is configured in a hand-held form factor, then one can efficiently and conveniently deploy the DPI to detect the presence of special nuclear materials (SNM) and identify any isotopic variations that differ from their natural abundances. Here we show that by maximizing the areal coupling between a pixelated scintillator array and the partitioned photosensor readout such as a silicon photomultiplier (SiPM), the information utilization of the gamma-ray and neutron information in the radiation field can be enhanced, thus enabling one to rapidly acquire spatial maps of the distributions on gamma-ray and neutron emitters.