• Title/Summary/Keyword: Hand positions

Search Result 243, Processing Time 0.025 seconds

Development of a 3D Semi-Automatic Measurement Protocol for Hand Anthropometric Measurement (손 치수 측정을 위한 3차원 반자동 측정 방법 개발)

  • Lee, Won-Sup;Yoon, Sung-Hye;You, Hee-Cheon
    • IE interfaces
    • /
    • v.24 no.2
    • /
    • pp.105-111
    • /
    • 2011
  • Measurement protocols for hand anthropometry have been studied for ergonomic product design. The present study developed a 3D semi-automatic measurement protocol (3D-SAMP) which semi-automatically measures various hand dimensions using a 3D scanner. The 3D-SAMP was compared with the conventional direct measurement method (DMM) to examine its effectiveness. The 3D-SAMP consists of (1) fabricating a plaster cast of the hand, (2) placing landmarks on the plaster hand, (3) scanning the plaster hand with a 3D scanner, (4) identifying automatically the positions of the landmarks on the digital hand, and (5) extracting automatically hand anthropometric measurements (lengths, widths, thicknesses, and circumferences). An evaluation experiment conducted in the study found the 3D-SAMP preferred to the DMM in terms of reliability (the number of dimensions exceeding the variability criteria SD=2 mm and CV=5% : 3D-SAMP =2 and DMM=24) and ease of measurement (3D-SAMP=5.2 and DMM=4.3 out of 7). The 3D-SAMP can be applied to ergonomic design of a hand-held product.

Microstructure and Mechanical Properties of a Copper Alloy Sheet Processed by a Differential Speed Rolling (이속압연에 의해 가공된 동합금 판재의 조직 및 기계적 특성)

  • Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.581-586
    • /
    • 2012
  • The microstructure and mechanical properties of a copper alloy sheet processed by differential speed rolling (DSR) were investigated in detail. A copper alloy with thickness of 3 mm was rolled to a 50% reduction at ambient temperature without lubrication and with a differential speed ratio of 2.0:1. For comparison, conventional rolling (CR), in which the rolling speeds of the upper and lower rolls is 2.0 m/min, was also performed under the same rolling conditions. The shear strain of the sample processed by CR showed positive values at the positions of the upper roll side and negative values at the positions of the lower roll side. On the other hand, the sample processed by the DSR showed zero or positive shear strain values at all positions. However, the microstructure and mechanical properties of the as-rolled copper alloys did not show such significant differences between the CR and the DSR. The samples rolled by the CR and the DSR exhibited a typical deformation structure. In addition, the DSR processed samples showed a typical rolling texture in which {112}<111>, {011}<211> and {123}<634> components were developed at all positions. Therefore, it is concluded that the DSR was very effective for the introduction of a uniform microstructure throughout the thickness of the copper alloy.

Study on Changes in the Grip Strength of Normal Adults Depending on the Position of the Forearm

  • Lee, Jun Chel;Gim, Min A
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.1
    • /
    • pp.1406-1412
    • /
    • 2018
  • This study aimed to measure the grip strength of the dominant and non dominant hands of right-handed normal adults in the supination, pronation, and neutral positions of the forearms. The subjects of this study were instructed to make the standard posture suggested by the American Society of Hand Therapists (ASHT) in order to minimize the impact of changes in the posture of the body as follows. The grips strength was statistically different between groups (p<.05). In the follow up test using Scheffe test, the grips in the neutral position and supinator position did not show any difference, while the grip in the pronation was smaller than those of the above two other positions. The grips of the mainly used forearm and non-mainly used forearm of the study target did not show any statistically significant difference in the neutral, supinator and pronation positions of the forearm. This study is expected to provide basic information for studying the impact of the positions of the forearms on grip strength, assessing the prehensility of patients in clinical settings, and setting therapeutic goals.

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.

A New Ultrasound Bladder Scanner to Estimate Urine Volume Using Hand-Motion Scan (손 동작 스캔을 이용한 잔뇨량 측정용 초음파 방광 스캐너)

  • Lee, Jung Hwan;Bae, Jung Ho;Lee, Soo Yeol;Cho, Min Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.153-160
    • /
    • 2018
  • 3D ultrasound bladder scanners are getting popular in hospitals for the patients with bladder dysfunction. A current bladder scanner adopts a mechanical scan to acquire 3D images and requires two motors and complicated mechanical devices. In this paper, we propose a new ultrasound bladder scanner using hand-motion scan. Instead of two motors and mechanical devices, it has a motion sensor to record transducer positions during hand-motion scan. The experiments with a bladder phantom and volunteers showed similar measurement accuracy to a conventional 3D ultrasound bladder scanner. We expect that the proposed method will reduce the cost and size of the bladder scanner.

Controlled active exercise after open reduction and internal fixation of hand fractures

  • Jun, Dongkeun;Bae, Jaehyun;Shin, Donghyeok;Choi, Hyungon;Kim, Jeenam;Lee, Myungchul
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.98-106
    • /
    • 2021
  • Background Hand fractures can be treated using various operative or nonoperative methods. When an operative technique utilizing fixation is performed, early postoperative mobilization has been advocated. We implemented a protocol involving controlled active exercise in the early postoperative period and analyzed the outcomes. Methods Patients who were diagnosed with proximal phalangeal or metacarpal fractures of the second to fifth digits were included (n=37). Minimally invasive open reduction and internal fixation procedures were performed. At 3 weeks postoperatively, controlled active exercise was initiated, with stress applied against the direction of axial loading. The exercise involved pain-free active traction in three positions (supination, neutral, and pronation) between 3 and 5 weeks postoperatively. Postoperative radiographs and range of motion (ROM) in the interphalangeal and metacarpophalangeal joints were analyzed. Results Significant improvements in ROM were found between 6 and 12 weeks for both proximal phalangeal and metacarpal fractures (P<0.05). At 12 weeks, 26 patients achieved a total ROM of more than 230° in the affected finger. Postoperative radiographic images demonstrated union of the affected proximal phalangeal and metacarpal bones at a 20-week postoperative follow-up. Conclusions Minimally invasive open reduction and internal fixation minimized periosteal and peritendinous dissection in hand fractures. Controlled active exercise utilizing pain-free active traction in three different positions resulted in early functional exercise with an acceptable ROM.

Construction of Skin Color Map for Resolving Hand Occlusion in AR Environments (증강현실 환경에서 손 가림 해결을 위한 피부 색상 정보 획득)

  • Park, Sang-Jin;Park, Hyungjun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.2
    • /
    • pp.111-118
    • /
    • 2014
  • In tangible augmented reality (AR) environments, the user interacts with virtual objects by manipulating their physical counterparts, but he or she often encounters awkward situations in which his or her hands are occluded by the augmented virtual objects, which causes great difficulty in figuring out hand positions, and reduces both immersion and ease of interaction. To solve the problem of such hand occlusion, skin color information has been usefully exploited. In this paper, we propose an approach to simple and effective construction of a skin color map which is suitable for hand segmentation and tangible AR interaction. The basic idea used herein is to obtain hand images used in a target AR environment by simple image subtraction and to represent their color information by a convex polygonal map in the YCbCr color space. We experimentally found that the convex polygonal map is more accurate in representing skin color than a conventional rectangular map. After implementing a solution for resolving hand occlusion using the proposed skin color map construction, we showed its usefulness by applying it to virtual design evaluation of digital handheld products in a tangible AR environment.

A Study on the Efficiency of Hand-Knee Position in GB Stone Ultrasonography (담낭결석 초음파검사에서 Hand-Knee position의 효율성에 관한 연구)

  • Park, Soung-Ock;Do, Yun-Su
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.267-274
    • /
    • 2006
  • The evaluation of GB stones with ultrasound has proved to be useful procedure in patient with symptoms of cholelithiasis. GB is evaluated for size, wall thickness, presence of internal reflections within the lumen and posterior acoustic shadowing or enhancement in Ultrsonography. The patient position should be shifted during procedure to demonstrate further the presence of stone within the GB. Patient scanned at the Rt. subcostal region in supine, right lateral, Lt. down decubitus, and upright sitting position. So GB stone should shift to dependent area of GB. Often, GB is not markedly distended in the presence of cholethiasis, and so the diagnosis becomes more difficult. One of the more difficult areas for detection of a GB stones are embeded in the cystic duct region. And since the GB is adjacent to the duodenum and hepatic flexure, its may be difficult to visualizing a GB stone. When patient study position changes frome supine to other position, stones displaced the site. But if its are polyps, not changes the site whatever patient positions. It is very important to what make different GB stones or polyps. We have studied about mobility of GB stones according to the patients position(supine, Lt. down decubitus, $30^{\circ} LAO. sitting and hand-knee). So we have a result, stones wherever localized within the GB, changed 100% its position in the hand-knee position and the others appeared at least 90%. In this study, when a large stones are located through fundus-body and body-neck, does not changing the stones position in spite of varied patient's positions. But hand-knee positions can identified GB stones, because its make changed the position of stons from posterior wall to anterior wall within the GB. We recommend the hand-knee position for differentiation GB stones from polyps.

  • PDF

Markless System of Using Hand Tracking (핸드 트레킹을 이용한 Markerless 시스템)

  • Ban, Kyeong-Jin;Kim, Jong-Chan;Kim, Kyeong-Og;Kim, Eung-Kon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.683-685
    • /
    • 2010
  • Augmented reality is a technology for showing virtual objects overlapped with the real world as seen from the eyes of users. Studies are being conducted on effective communication methods using hand movements in augmented reality. Hand movements are an important means of human communication along with writing and voice. Space arrangement technology and hand tracking technology using markers to acquire virtual information in augmented reality have many limitations. This paper proposes tracking hand area for augmented object. The augmented objects change viewpoints by hand positions which improves the sense of three dimensions and immersion.

  • PDF

Tracking and Recognizing Hand Gestures using Kalman Filter and Continuous Dynamic Programming (연속DP와 칼만필터를 이용한 손동작의 추적 및 인식)

  • 문인혁;금영광
    • Proceedings of the IEEK Conference
    • /
    • 2002.06c
    • /
    • pp.13-16
    • /
    • 2002
  • This paper proposes a method to track hand gesture and to recognize the gesture pattern using Kalman filter and continuous dynamic programming (CDP). The positions of hands are predicted by Kalman filter, and corresponding pixels to the hands are extracted by skin color filter. The center of gravity of the hands is the same as the input pattern vector. The input gesture is then recognized by matching with the reference gesture patterns using CDP. From experimental results to recognize circle shape gesture and intention gestures such as “Come on” and “Bye-bye”, we show the proposed method is feasible to the hand gesture-based human -computer interaction.

  • PDF