• 제목/요약/키워드: Hand Device

검색결과 779건 처리시간 0.025초

A Self-Reconfigurable System of Contents among Smart Devices

  • Ren, Hao;Kim, Paul;Kim, Sangwook
    • Journal of Multimedia Information System
    • /
    • 제2권2호
    • /
    • pp.223-232
    • /
    • 2015
  • In this system, mobile devices are not independent, they can communicate with each other, one device's change can affect the whole system or other devices. To achieve the above mentioned A Self-Reconfigurable System of Contents, through discover the device and connect process, to establish the connection between the mobile devices. After user assigns two dimension display type, the user can select content to input the system, contents are portioning and broadcast to devices. The system can self-reconfigure contents rapidly and exactly. This technique supports contents self-reconfiguration for devices remove, addition and position exchange. In this paper, when the user uses the hand contacts device, the device sends a signal to assist the system to detection device's position. The system does not need to get accurate devices moving direction, just according to all changed devices position to judge where the devices destination is. This research develops an application according to this technique, and the real machine tests the application using Android platform. Some communication protocols and mathematical modeling methods are proposed. These methods can also be used in other Internet of Things (IoT) fields, such as Drones Navigation, Smart Home, and Informational City management.

MR 유체를 이용한 촉감구현장치의 설계 및 성능 평가 (Design and Performance Evaluation of Tactile Device Using MR Fluid)

  • 김진규;오종석;한영민;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.415-420
    • /
    • 2012
  • This paper proposes a novel type of tactile device utilizing magnetorheological (MR) fluid which can be applicable for haptic master of minimally invasive surgery (MIS) robotic system. The salient feature of the controllability of rheological properties by the intensity of the magnetic field (or current) makes this potential candidate of the tactile device. As a first step, an appropriate size of the tactile device is designed and manufactured via magnetic analysis. Secondly, in order to determine proper input magnetic field the repulsive forces of the real body parts such as hand and neck are measured. Subsequently, the repulsive forces of the tactile device are measured by dividing 5 areas. The final step of this work is to obtain desired force in real implementation. Thus, in order to demonstrate this goal a neuro-fuzzy logic is applied to get the desired repulsive force and the error between the desired and actual force is evaluated.

  • PDF

Investigating the effect of changing parameters in the IEC device in comparative study

  • H. Ghammas;M.N. Nasrabadi
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.292-300
    • /
    • 2024
  • Kinetic simulations have been performed on an Inertial Electrostatic Confinement Fusion (IECF) device. These simulations were performed using the particle-in-cell (PIC) method to analyze the behavior of ions in an IEC device and the effects of some parameters on the Confinement Time (CT). CT is an essential factor that significantly contributes to the IEC's performance as a nuclear fusion device. Using the PIC method, the geometry of a two-grided device with variable grid radius, the number of cathode grid rings, variable pressure and different dielectric thickness for the feed stalk was simulated. In this research, with the development of previous works, the interaction of particles was simulated and compared with previous results. The simulation results are in good agreement with the previous results. In these simulations, it was found that with the increase of the dielectric thickness of the feed stalk, the electric field was weakened and as a result, the confinement time was reduced. On the other hand, with the increase of the cathode radius, the confinement time increased. Using the results, an IEC device can be designed with higher efficiency and more optimal CT for ions.

Problem Analysis and Recommendations for Using Manual Wheelchair for One-hand Users

  • Park, Gemus;Hwang, Jung Bo;Jung, Hwa Shik
    • 대한인간공학회지
    • /
    • 제33권2호
    • /
    • pp.109-124
    • /
    • 2014
  • Objective: This study was conducted for one-hand users including hemiplegic clients currently using general folding manual wheelchairs, so as to analyze their specific problems and recommend solutions regarding usage. Background: Traditional manual wheelchairs require considerable use and control of both hands for operation, thus adaptations become necessary for individuals with asymmetrical use of hands. Method: Thirty hemiplegic clients who were admitted to rehabilitation and convalescent hospitals participated as subjects. The research tools were general folding manual wheelchairs commonly used by people with impaired gait, and the Wheelchair Skills Tests (WST) WST-M/WCU 4.1 version was adopted as the assessment tool. All participants were asked to fill out questionnaires on demographics and wheelchair usage characteristics. Assessment procedures were performed with currently used manual wheelchairs and with/without the use of foot to control the wheelchair. Results: When the participants drove folding manual wheelchairs without the use of foot, even the lowest failure rate among the WST items tested recorded 96.7%. On the contrary, with the use of foot in maneuvering the wheelchairs, failure rates dropped noticeably and success rate among the WST items tested was as high as 86.7%. Conclusion: These findings imply that the use of one-arm (hand) propellable (drivable) wheelchair can be an active and effective solution in resolving problems for hemiplegic clients using existing manual wheelchairs. As such, the government should provide institutional support to further develop and distribute this device or technology, and promote relative research in tandem. For now, the supply of commercially available device to hemiplegic clients is deemed urgent and also a mechanism to provide the devices and relevant services. Application: This study offers viable solutions for hemiplegic clients who rely on existing manual wheelchairs to increase their mobility and occupational performance.

독사 교상 환자에서의 음압요법: 예비보고 (Vacuum Assisted Closure Therapy in Snake Bite Wound: Preliminary Report)

  • 송우진;최환준;강상규
    • Archives of Plastic Surgery
    • /
    • 제38권1호
    • /
    • pp.121-126
    • /
    • 2011
  • Purpose: Vaccum-assisted closure (VAC) has rapidly evolved into a widely accepted treatment of contaminated wounds, envenomations, infiltrations, and wound complications. This results in a sealed, moist environment where tissue is given the opportunity to survive as edema is removed and perfusion is increased. Many plastic surgeons now place a VAC device directly over the fasciotomy site at the time of the initial procedure. Large amounts of the fluid are withdrawn, and fasciotomies can be closed primarily sooner. This study was designed to observe the effect of VAC in preventing complications in snake bitten hands. Methods: In our study of three cases of snake bite, three of them underwent the VAC treatment & fasciotomy of the wound in the hand. This cases, the posterior compartment of the hand was bitten for a few days, releasing incisions were made of the posterior hand and 125 mmHg of continuous vacuum was applied to fasciomy incision site and the biting wound. The dressings were changed three times per week. Results: Our study examining the effects of applied vacuum in preventing snake bite wounds showed that the incidence of tissue necrosis and compartment syndrome was significantly lower for vacuum-treated wounds than for conservative wounds. Serum myoglobin, CK-MB, and CPK levels measured after fasciotomy incision were significantly decreased. We obtained satisfactory results from early dorsal fasciotomy, drainage of the edema with the VAC system, and then primary closure. The postoperative course was uneventful. Conclusion: Envenomation is a term implying that sufficient venom has been introduced into the body to cause either local signs at the site of the bite and/or systemic signs. Use of the vacuum-assisted closure device in snake bite can result in a decreased rate of tissue necrosis, lymphatic fluid collection, hemolytic fluid collection, and edema. Early fasciotomy of the dorsal hand and VAC apply is the alternative treatment of the snake bite.

Volume Control using Gesture Recognition System

  • Shreyansh Gupta;Samyak Barnwal
    • International Journal of Computer Science & Network Security
    • /
    • 제24권6호
    • /
    • pp.161-170
    • /
    • 2024
  • With the technological advances, the humans have made so much progress in the ease of living and now incorporating the use of sight, motion, sound, speech etc. for various application and software controls. In this paper, we have explored the project in which gestures plays a very significant role in the project. The topic of gesture control which has been researched a lot and is just getting evolved every day. We see the usage of computer vision in this project. The main objective that we achieved in this project is controlling the computer settings with hand gestures using computer vision. In this project we are creating a module which acts a volume controlling program in which we use hand gestures to control the computer system volume. We have included the use of OpenCV. This module is used in the implementation of hand gestures in computer controls. The module in execution uses the web camera of the computer to record the images or videos and then processes them to find the needed information and then based on the input, performs the action on the volume settings if that computer. The program has the functionality of increasing and decreasing the volume of the computer. The setup needed for the program execution is a web camera to record the input images and videos which will be given by the user. The program will perform gesture recognition with the help of OpenCV and python and its libraries and them it will recognize or identify the specified human gestures and use them to perform or carry out the changes in the device setting. The objective is to adjust the volume of a computer device without the need for physical interaction using a mouse or keyboard. OpenCV, a widely utilized tool for image processing and computer vision applications in this domain, enjoys extensive popularity. The OpenCV community consists of over 47,000 individuals, and as of a survey conducted in 2020, the estimated number of downloads exceeds 18 million.

Frequency Domain Sampling 방식의 Surface Acoustic Wave Sensor Platform 설계 및 구현 (The Design and Implementation of Frequency Domain Sampling Surface Acoustic Wave Sensor Platform)

  • 조율희;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.220-223
    • /
    • 2012
  • 현재 일반적으로 사용되는 Time Domain Sampling(아래 TDS) 방식의 SAW Device는 빠른 Data 처리를 할 수 있지만 그만큼의 빠른 sampling 속도를 요구하기 때문에 고속의 AD 컨버터가 필요하다. 이 고속의 AD 컨버터는 고가의 장비로 Device 제작에 부담이 되는 실정이다. 반면에 Frequency Domain Sampling(아래 FDS) 방식으로 구현된 SAW Device는 고속의 sampling을 요구하지 않기 때문에 고가의 고속 AD 컨버터가 필요하지 않다. 이렇게 느린 sampling 속도는 상대적으로 고속의 processing을 요구하게 되는데 이는 저가의 Embedded System만으로도 구현이 가능하기 때문에 가격대비 성능에서 효율이 훨씬 높다고 할 수 있다. 그럼에도 FDS 방식의 SAW sensor를 제작하는 것이 까다롭기 때문에 현재 구현된 FDS 방식의 SAW Device는 매우 드문 실정이다. 본 연구에서는 이 문제를 해결하기 위해 기존의 TDS용 SAW sensor를 그대로 이용한 FDS 방식의 SAW Device에 대해 설계 및 구현한다.

  • PDF

Cortex-A8을 이용한 Frequency Domain Sampling 방식의 Surface Acoustic Wave Sensor Platform 설계 및 구현 (The Design and Implementation of Frequency Domain Sampling Surface Acoustic Wave Sensor Platform using Cortex-A8)

  • 조율희;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.312-315
    • /
    • 2012
  • 현재 일반적으로 사용되는 Time Domain Sampling(아래 TDS) 방식의 SAW Device는 빠른 Data 처리를 할 수 있지만 그만큼의 빠른 sampling 속도를 요구하기 때문에 고속의 AD 컨버터가 필요하다. 이 고속의 AD 컨버터는 고가의 장비로 Device 제작에 부담이 되는 실정이다. 반면에 Frequency Domain Sampling(아래 FDS) 방식으로 구현된 SAW Device는 고속의 sampling을 요구하지 않기 때문에 고가의 고속 AD 컨버터가 필요하지 않다. 이렇게 느린 sampling 속도는 상대적으로 고속의 processing을 요구하게 되는데 이는 저가의 Embedded System만으로도 구현이 가능하기 때문에 가격대비 성능에서 효율이 훨씬 높다고 할 수 있다. 그럼에도 FDS 방식의 SAW sensor를 제작하는 것이 까다롭기 때문에 현재 구현된 FDS 방식의 SAW Device는 매우 드문 실정이다. 본 연구에서는 이 문제를 해결하기 위해 기존의 TDS용 SAW sensor를 그대로 이용한 FDS 방식의 SAW Device에 대해 설계 및 구현한다.

  • PDF

음원을 이용한 멀티미디어 휴대용 단말장치 판별 (Hand-held Multimedia Device Identification Based on Audio Source)

  • 이명환;장태웅;문창배;김병만;오득환
    • 한국산업정보학회논문지
    • /
    • 제19권2호
    • /
    • pp.73-83
    • /
    • 2014
  • 다양한 오디오 편집 기술이 개발됨으로써 오디오 데이터의 변경이 보다 쉬워지고 그 결과로 위변조 같은 다양한 사회 문제가 발생하고 있다. 현재 이런 문제를 해결하기 위해 디지털 포렌식 기술이 활발히 연구되어지고 있다. 본 논문에서는 이러한 디지털 포렌식 기술 중의 하나로 모바일 기기를 판별하는 방법을 제안하였다. 제안 방법에서는 사람에게는 들리지 않지만 기기의 디자인과 IC로부터 발생하는 노이즈 특징을 이용한다. 위너필터를 사용하여 기기의 노이즈 음을 추출하고 MIRtoolbox를 이용하여 특징들을 추출한 후 이를 다층 신경망에 학습시켜 기기를 판별한다. 총 6개의 모바일 기기를 사용하였으며 5-fold test를 통하여 99.9%의 판별 성능을 보였다. 또한 UCC 사이트에 업로드 된 데이터에서도 노이즈 음을 통한 판별이 가능한지 실험을 진행하였으며 99.8%의 판별 성능을 보였다.

손등피부 운동 마찰계수 측정기를 이용한 체질 판별 가능성 연구 (A Feasibility Study of Constitution Discrimination Using a Measurement Device for Dynamic Friction Coefficients of the Back of a Hand)

  • 김근호;우영재;이혜정;이유정;김종열
    • 사상체질의학회지
    • /
    • 제22권4호
    • /
    • pp.20-29
    • /
    • 2010
  • 1. Objectives Our goal is to observe the feasibility of constitution discrimination from computing quantitative roughness index from dynamic friction coefficients and their gradients with the measurement device of skin friction with 3-Axis load cell sensor. 2. Methods In the traditional Korean medicine, skin diagnosis is one of the examination methods to discriminate Sasang constitution since it was known that Tae-eumin has rough skin, and Soyangin has smooth one. It is based on the skin roughness on the back of one's hand for the discrimination. The measurement device of skin friction with 3-axis load cell sensor has been developed in order to provide quantitative skin roughness through dynamic friction coefficients. The effective interval of the coefficients is obtained from the automatic sampling algorithm to use their curvature and slope. Then, Fisher's discriminant function of them makes the discrimination. 3. Results The success rate of extracting the effective interval was about 90% and the discriminant accuracy between Tae-eumin and Soyangin was 70% and 68% for men and women, respectively. The entire methods showed the possibility to distinguish between Tae-eumin and Soyangin by using stochastic properties of roughness index, which can make the entire system to include the measurement, the computation of the roughness index and the discrimination of constitution automatical. 4. Conclusions The measurement device, the automatic sampling algorithm of dynamic friction coefficients and the constitution discrimination algorithm were developed, respectively, and their combination can become the serial and automatic procedure for quantitative and objective skin diagnosis, which mimics the movement of the Oriental medical doctors' skin diagnosis. It can be applied to healthcare as well as the diagnosis of constitution in a u-Health system soon.