• Title/Summary/Keyword: Ha-So

Search Result 3,559, Processing Time 0.043 seconds

Mobility Management Scheme Using Efficient Relay Agent in Nested Mobile Networks (중첩된 이동망에서 효율적 릴레이 에이전트를 사용하는 이동성 관리 기법)

  • 이재걸;홍충선;이재조
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10A
    • /
    • pp.796-806
    • /
    • 2003
  • Mobile Node usually communicate with CN bia only it's own HA but Nested Mobile Networks correspond with CN bia all HA involved with them. when Mobile Network of a MR moves from its home link to a foreign link in the stationary network. then Mobile Network of another MR moves from its home link in stationary network to foreign link in previous mobile network. CN send Packet destined to the latter MR via both Home Agent of the former MR and the latter MR. There are two problem in this scenario. One is inefficient routing path that bypass via several HA. the other is waste of transmission resource and delay of Registration process which change of Nested Mobile Network Architecture cause Mobile Router. so We propose MRA(Mobile Relay Agent) to support effective routing by local mobility management.

Runoff Characteristics of Non-point Source Pollutants by Rainfall : Case Study with Pappy Field (강우시 비점오염물질의 유출 특성: 논을 대상으로)

  • Ju, So Hee;Park, Woon Ji;Shin, Jae Young;Lee, Su In;Choi, Joong Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.552-552
    • /
    • 2016
  • 논의 경우 다양한 영향인자에 의해 비점오염물질이 배출되기 때문에 유출특성을 파악하기가 어렵다. 따라서 본 연구의 목적은 논에서 발생하는 비점오염물질의 유출 특성에 대해 파악하여 추후 효율적인 농업비점오염 관리를 위한 기초자료를 제공하는데 있다. 연구 대상지점으로 춘천시에 위치한 논 1곳(면적: $11,130m^2$)을 선정하였으며. 2014년 5월부터 9월까지 총 11회(9회 유출)의 강우 사상에 대한 오염물질별 오염부하 및 유량가중평균농도(Event Mean Concentration, EMC)를 산정하였다. 모니터링기간 동안 발생된 강우량의 범위는 2.6~95.8 mm로 나타났으며, 선행무강우일수는 0.59~21.2일, 강우강도는 0.33~5.13 mm/hr의 범위로 나타났다. 총 유출량은 $0.16{\sim}497.3m^3$, 유출율은 0.01~0.47(평균 0.24)의 범위로 나타났다. 오염물질별 EMC는 SS 17.1~55.3 mg/L(평균 31.9 mg/L), BOD 1.9~9.7 mg/L(평균 4.2 mg/L), COD 3.6~18.9 mg/L(평균 8.3 mg/L), TOC 3.4~17.4(평균 6.4 mg/L) mg/L, T-N 1.64~7.17 mg/L (평균 3.79 mg/L), T-P 0.16~1.04 mg/L(평균 0.44 mg/L)의 범위로 나타났다. 각 강우사상에 대한 단위면적당 오염부하는 SS 0.005~19.56 kg/ha, $BOD_5$ 0.001~1.70 kg/ha, $COD_{Mn}$ 0.003~3.15 kg/ha, TOC 0.002~1.81 kg/ha, T-N 0.001~0.822 kg/ha, T-P 0.00003~0.115 kg/ha의 범위로 산정되었다. 논의 경우에는 초기유출 발생에 따른 오염부하의 급격한 변화가 없었고, 누적오염부하량비의 그래프도 강우사상의 기울기가 직선에 가깝게 나타났다. 하지만 지속적으로 오염물질을 배출하는 경향과 다양한 조건에 따라 배출양상이 달라지기 때문에 효과적인 관리를 하기 위해서 장기적인 모니터링 연구가 필요할 것으로 사료된다.

  • PDF

On the base inflectional forms of Korean old vernacular letters (언간에 나타나는 어기활용형에 대한 고찰)

  • Lee, Hyun-Ju
    • (The)Study of the Eastern Classic
    • /
    • no.56
    • /
    • pp.297-329
    • /
    • 2014
  • This paper aims to examine the base inflectional forms of Korean old vernacular letters, and explain why it appears with frequency. In the korean old vernacular letters, the suffix 'ha-' and ending of the 'Base+ha-' adjective derivation are not appear with extraordinary frequency. I called it the base inflectional forms. I consider it in function and morphological constructions and also the syntactic constructions. Whenever Joseon-era people wrote a letter with a time limit, they have need to diminish their exertion to use of the brush. Therefore the base inflectional forms appear with extraordinary frequency in comparison with other papers. In the 'X ha-' word formation of Korean old vernacular letters, 'ha-' is formal morpheme without substantial meaning. So 'X' is left and 'ha-' and ending can be omitted resolutely. The base inflectional forms are occurred to voluntary language performance for a particular intention. but it is not appear in all conditions. In some circumstances, it appear. I checked out the constructions on base inflectional forms. In the 'X ha-' word formation, 'X' is predicative base without fail. and the ending which take part in base inflectional forms has a grammatical function unadulteratedly.

Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류 모니터링용 실시간 무선 원격 감시 시스템)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2729-2731
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. In this paper, results of development about Real-time Wireless Remote Monitoring System for Stray Current of Subway System are presented.

  • PDF

Study on crystal texture of PIT processed Bi-2223 multi-filamentary tape (PIT 공정으로 제조한 Bi-2223 다심 고온 초전도 선재의 결정 배향성에 관한 연구)

  • Choi, J.K.;Oh, S.S.;Ha, H.S.;Yang, J.S.;Yun, J.K.;Lee, N.J.;Ha, D.W.;Kwan, Y.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.59-63
    • /
    • 2002
  • The purpose of this paper is to investigate the crystal texture of the 2223 phase and its relationship with PIT processing parameter. Ag-sheathed Bi-2223 multi-filament tapes were prepared by changing rolling reduction ratio. We analysed the degree of texture for 2223 phase after heat-treatment. According to X-ray pole-figure, the texture of the filaments located near surface and center were not so different each other for all rolling conditions. we found a little higher degree of texture for 60% rolling reduction. But its difference is not so high compared with those tapes with a lower rolling reduction ratio. Reaction induced texturing seemed to contribute with a large portion under present condition.

  • PDF

A Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA (국가 기간 시설물의 전식 대책(안))

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1609-1611
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) system of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. In this paper, the mechanism of mitigation method of DC stray current for underground metallic structures is described.

  • PDF

A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA (국가기간시설물의 전식대책(안) 및 그 적용 사례(1))

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF

Oxidative Transformation of Tetracycline in Aqueous Solution by Birnessite (망간산화물(birnessite)에 의한 수용액 중 Tetracycline의 산화-변환반응에 대한 연구)

  • Eom, Won-Suk;Kim, So-Hui;Shin, Hyun-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • An investigation on the removals of tetracycline (TTC), which is a family of antibiotics widely founded in the environment, from the aqueous solution by birnessite(${\delta}-MnO_2$)-mediated oxidative transformation was described. This study also examined the potential effect of the naturally occurring substances, humic acid (HA) on the oxidative transformation. The experiment was carried out in various conditions (reaction time, Mn oxide loadings, pH) and in the presence of HA as a batch test. The removals of TTC followed pseudo-first order reactions, and rate constants (k, $hr^{-1}$) for the removals of TTC were constantly increased with decreasing pH from 0.98 (pH 9) to 2.97 (pH 3). The rate constants also increased about 1.3 times when the birnessite loading increased from 1 to 2 g/L. Presence of HA (5 mg-C/L, at $pH{\geq}6$) caused some enhancement in the removals of TTC as compared to the control, and also showed the removal efficiencies of TTC in the birnessite mediated systems (TTC=0.25 mM, ${\delta}-MnO_2=2.0g/L$, pH 6) increased with increasing HA concentrations (1~10 mg-C/L). The results obtained from the oxidative transformation of TTC and the effect of HA were discussed in terms of reaction characteristics and mechanism.

Effect of Additives on Preparation of Porous Alumina Membrane by Anodic Oxidation in Sulfuric Acid (황산전해조에서 양극산화에 의한 다공성 알루미나 막의 제조시 첨가제의 영향)

  • Lee, Chang-Woo;Lee, Yoong;Kang, Hyun-Seop;Chang, Yoon-Ho;Hong, Young Ho;Hahm, Yeong-Min
    • Applied Chemistry for Engineering
    • /
    • v.9 no.7
    • /
    • pp.1030-1035
    • /
    • 1998
  • The porous alumina membrane was prepared from aluminum metal(99.8%) by anodic oxidation using DC power supply of constant current mode in an aqueous solution of sulfuric acid. To prevent the chemical dissolution of alumina membrane, $Al_2(SO_4)_3$, $AlPO_4$ and $Al(NO_3)_3$ which could be considered to supply $Al^{3+}$ ions were added to electrolyte solution at a reaction temperature of $20^{\circ}C$ and cumulative charge of $150C/cm^2$. Effects of these additives on the formation of porous alumina membrane were evaluated under various electrolyte concentration(5~20 wt%) and current densities($10{\sim}50mA/cm^2$). The membrane surfaces which were prepared in electrolyte solution with all the additives except $Al_2(SO_4)_3$ were damaged. However, when $Al_2(SO_4)_3$ was added to the $H_2SO_4$ solution, an uniform surface of porous alumina was obtained. Also, it was shown that the pore size of membrane was nearly independent on the quantity of $Al_2(SO_4)_3$ added at same electrolyte concentration and current density.

  • PDF

SO2 Removal by Internal Circulation of de-SOx Absorbents (흡수제 내부순환형 탈황장치의 SO2 제거성능 특성)

  • Park, Young-Ok;Park, Hyun-Jin;Kim, Yong-Ha
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.672-680
    • /
    • 2011
  • Three new granular absorbents were prepared from calcium hydroxide, and applied to an FGD process with internal circulation. The aim of the study was finding the most efficient of the these three applied absorbents for the $SO_2$ removal at high flue gas temperatures. The absorbent is fed to the testing unit at high operation temperature and fluidized inside the FGD system where the sorbent particles react with the $SO_2$ gas. The rate of $SO_2$ decomposition was high in C-type absorbent which had the large surface area. De-SOx characteristics of the current absorbents appeared to be similar to the other conventional agents in this fluidized bed combustor. In particular, the optimum de-SOx condition could be achieved at high mole ratios of Ca to S which can reduce the residual $SO_2$.