• Title/Summary/Keyword: HVDC converter

Search Result 181, Processing Time 0.026 seconds

Circulating Current Control of a Modular Multi-level Converter(MMC)-HVDC System based on VPI(Vector-PI) Control for DC Power Network (DC 전력망 구축을 위한 VPI 제어 기반 MMC-HVDC 시스템의 순환전류 제어 기법)

  • Kim, Si-Hwan;Lee, June-Sun;Cho, Young-Pyo;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.263-269
    • /
    • 2017
  • This paper proposes a novel circulating current control method for an MMC-HVDC system based on Vector PI control. The method can suppress second-order harmonics of the circulating currents under balanced and unbalanced grid conditions. The proposed method is robust to grid frequency variation. The effectiveness of the proposed method is verified through frequency response and time domain simulation.

Grid Voltage Regulation with MMC-HVDC System

  • Quach, Ngoc-Thinh;Jeong, Woo-Cheol;Yang, Hang-Jun;Choi, Jong-Yun;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.146-147
    • /
    • 2014
  • This paper presents an operation of the modular multilevel converter-high voltage direct current (MMC-HVDC) system as a Statcom to support the grid voltage. The advantage of the MMC-HVDC system is that it can control the active and reactive powers independently. The proposed control scheme will be designed by combining this performance and the control method of the Statcom. The grid voltage is regulated by the control of the reactive power, meanwhile the active power is controlled according to its applications. The simulation results based on the PSCAD/EMTDC simulation program will evaluate the effectiveness of the control scheme.

  • PDF

Study of Electrode Cracking in High Voltage Direct Current System (초고압 직류 설비의 전극봉 부식원인에 대한 연구)

  • Park, Jong-Kwang;Kim, Chan-Ki;Yang, Byoung-Mo;Choy, Young-Do;Han, Byeong-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.525-526
    • /
    • 2006
  • One of the electrode in Haenam converter, which is role of rectifier in Jeju-Haenam HVDC system is destroyed and we found many cracks at another electrode and we also found many cracks in Jeju converter station, which is role of inverter of Jeju-Haenam. HVDC system, there is no exact reason for these phenomenon, even though the life cycle of these electrode is 40 years. So, the experts for HVDC system in KEPCO and Anotec corporation, which is manufacturer of electrode, would perform research for the reason of electrode disorder. In this paper analyze the reason of electrode disorder and corrosion in high voltage direct current system.

  • PDF

Capacitance Value Analysis of Sub-module Test Circuit for MMC-based HVDC System (MMC 기반 HVDC 시스템용 서브모듈 시험회로의 커패시터 용량 분석)

  • Seo, Byuong-Jun;Park, Kwon-Sik;Jo, Kwang-Rae;Nho, Eui-Cheol;Kim, Heung-Geun;Chun, Tae-Won;Kim, Tae-Jin;Lee, Jong-Pil
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.433-439
    • /
    • 2018
  • This study considers the design of a submodule test circuit for the modular multi-level converter (MMC)-based HVDC systems. A novel submodule test circuit is proposed to provide not only an AC but also a DC component to the submodule current. However, the current waveforms depend on the capacitor voltages. Therefore, determining the capacitance value of the test circuit is important. Finding a proper capacitance value is easy when the proposed analysis method is used. Simulation and experimental results show the usefulness of the proposed method.

Predictive Direct Power Control in MMC-HVDC System (MMC-HVDC 시스템의 예측 기반 직접전력제어)

  • Lee, Kui-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.6
    • /
    • pp.403-407
    • /
    • 2018
  • This study proposes a predictive direct power control method in a modular multilevel converter (MMC) high-voltage direct-current (HVDC) system. The conventional proportional integral (PI)-based control method uses a cascaded connection and requires an optimal gain selection procedure and additional decoupling scheme. However, the proposed control method has a simple structure for active/reactive power control due to the direct power control scheme and exhibits a fast dynamic response by predicting the future status of system variables and considering time delay. The effectiveness of the proposed method is verified by simulation results.

Dynamic Performance of HVDC according to Excitation System Characteristics of Synchronous Compensator in a Weak AC System (약한 계통에서 동기조상기의 여자 시스템에 따른 HVDC 시스템의 과도 성능 분석)

  • 김찬기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.318-326
    • /
    • 2000
  • This paper analyses with the dynamic performance of HVDC System connected to a weak AC system for varying exciter characteristics of synchronous machines connected at the converter bus. Conventionally capacitors are used to supply reactive power requirement at a strong converter bus. However the installation and synchronous machine is essential in a isolated weak network to re-start after a shutdown of HVDC and to increase strength. The dynamic performance of a synchronous machine depends on the characteristics depends on its exciter characteristics. In this paper, several excites types are used to investigate their effect on the dynamic performance of the HVDC system and modifications to standard exciter topogical are suggested to mitigate observed problems.

  • PDF

The effect of HVDC#3 on Juju Power System (제주 HVDC#3 영향 분석)

  • Park, Jung-Soo;Jung, Hong-Ju;Kim, June-Sung;Suh, In-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.158-159
    • /
    • 2011
  • 최근 발표된 제5차 전력수급계획에 의하면 제주도에 3번째 HVDC 연계선 설치가 계획되고 있다. 이전까지 설치된 2개의 HVDC는 LCC(전류형) HVDC로써 안정적이고 우수한 성능으로 제주지역의 전력 수급에 기여를 했지만 전압 불안정 문제를 초래할 가능성을 가지고 있다. 따라서 3번째 HVDC는 VSC(전압형)으로 설치하는 것을 고려해야 한다. VSC HVDC는 유무효 전력이 동시에 제어가 가능하다는 장점이 있으나 비싼 가격과 높은 변환 손실, 그리고 작은 용량으로 제한적인 용도로만 사용되어 왔다. 그러나 최근 Multi-Level Converter 기술이 적용되면서 이전의 많은 문제들이 해결되었다. 이 논문에서는 VSC HVDC의 최신 동향에 대해서 간략히 소개하고 제주 전력망에 VSC HVDC가 설치되었을 때의 효과에 대해서 논의하고자 한다.

  • PDF

Transfer Capability Enhancement Using Voltage Source Converter HVDC (전압원 HVDC를 이용한 부하집중지로의 송전용량 증대방안)

  • Oh, Sea-Seung;Jang, Gil-Soo;Cha, Jun-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.328-330
    • /
    • 2005
  • This paper presents a transfer capability enhancement of using VSC HVDC system which can control reactive power as well as active power. The transfer capability is constrained by stability like voltage stability. These constraints may relieved by reactive power control ability of the VSC HVDC system. Site selection algorithm is also proposed.

  • PDF

A Study on Voltage Source HVDC System Operation Sequence (전압형 HVDC 구동 시퀀스에 대한 고찰)

  • Park, Sheng Hee
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.99-100
    • /
    • 2014
  • 전압형 HVDC(High Voltage Direct Current)는 현재 차세대 전력망으로써 각광을 받고 있고 그에 대한 연구가 활발하게 진행 중이다. 많은 논문에서 모듈형 멀티레벨 컨버터(Modular Multilevel Converter, MMC)의 제어 및 보호 방안에 대하여 기술하지만 운영적인 시퀀스 측면에 있어서는 아직 많은 연구가 진행되지 않고 있다. 이에 본 논문은 전압형 HVDC의 AC Yard, DC Yard 및 상위 제어기에 관한 구동 시퀀스에 대하여 기술하고자 한다.

  • PDF

Capacitance Estimation Method of VSC Type MMC HVDC (전압형 MMC HVDC 시스템의 커패시터 용량 추정 방법)

  • Sun, Daun;Song, Seong-geun
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.468-469
    • /
    • 2018
  • 본 논문에서는 MMC(Modular Multi-level Converter)타입 전압형 HVDC 서브모듈의 커패시터 용량을 추정하는 방법을 기술하였다. 서브모듈 내 별도의 전류센서 및 계측 시스템을 추가하지 않고 커패시터 용량을 추정하여 안정적인 HVDC 시스템의 동작이 가능하도록 하였으며 시뮬레이션을 통하여 타당성을 검증하였다.

  • PDF