• Title/Summary/Keyword: HRT

Search Result 616, Processing Time 0.032 seconds

Treatment Characteristics of Paper-mill Wastewater Using Pure Oxygen Activated Sludge Process (순산소 활성오니 공정을 이용한 제지폐수의 처리특성)

  • Kim, Sung Soon;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.27-34
    • /
    • 1999
  • An experimental study on improvement of the paper-mill wastewater treatment using the pure oxygen activated sludge process was conducted. The effects of hydraulic retention time(HRT) and BOD loading on organic removal efficiency were investigated. The BOD removal efficiencies were above 90% under all examined HRTs except for HRT of 3 hours. The increase of HRT from 3 hours to 6 hours, and to 12 hours significantly improved BOD and COD removal efficiencies, respectively. However, additional increase of HRT did not affect organic removal efficiency. F/M ratio change at fixed HRT did not affect organic removal efficiency. However, F/M ratio investigated in this study(0.11~1.98kgBOD/kgMLVSS/day) was 5 times greater in maximum than that of conventional activated sludge process, which implies that pure oxygen activated sludge process can treat wastewater with high organic strength. Under the same HRT, the volumetric BOD loading change cause no effect on organic removal efficiency also.

  • PDF

Effect of Hydraulic Retention Time on Biological Nitrogen Removal in Land-based Fish Farm Wastewater (육상양식장 배출수내 생물학적 질소처리시 수리학적 체류시간의 영향)

  • Park, Noh-Back
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.250-256
    • /
    • 2017
  • This study investigated the removal efficiency of organic matter and nitrogen from fish farm effluent by hydraulic retention time (HRT) using an upflow biological filter (ANR system) reactor. The recycling time and influent flow in the reactor were controlled to 14.8, 7.4, 5.5 and 3.2 h to evaluate HRT. In addition, each reactor was coupled to a fixed bed upflow filter charged with media. The results showed that removal efficiency was ${\geq}95%%$ with an HRT of 5.5 h, and nitrification efficiency was reduced to 81% with an HRT of 3.2 h, although nitrification efficiency temporarily decreased due to the shock load as HRT decreased. Total nitrogen removal rate was also reduced to about 65% with an HRT of 3.2 h, which was considered a washout effect of nitrifying and denitrifying microorganisms by increasing the shearing force to the filter media, which decreased organic matter and nitrogen removal efficiency.

On the Recycling Substances and a Clean Technology Development for the Treatment of Mixed Acid Waste Water with Ozone (오존을 이용한 혼산폐수처리에 관한 청정기술개발 및 재이용 물질 회수에 관한 연구)

  • 김재우
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.34-40
    • /
    • 2000
  • In the tungsten industry, molybdenum wire which used as the center supporter for coil shape tungsten wire was removed. Nitric acid dissolution method which used prevalently up to the present, takes nitric acid as major component and use noxious material such as sulfuric acid and hydrochloric acid remove molybdenum wire which used as center supporter by dissolve selectively within the range of no damage on tungsten wire. Mixed acid waste water occurred to the process were difficult to be decomposed by the conventional methords. This mixed acid waste water was treated by ozone, and It was obtained using possible by-product through the treatment waste water. For the three reactors with the same volume ; Blank reactor, Disturbance plate reactor, Packed-bed reactor ; the results were as follows : For the blank reactor COD removal efficiency in the pH = 4 (HRT : 6hr) was 28.5%, COD removal efficiency in the pH = 7 (HRT : 6hr) was 28.6%, and COD removal efficiency in the pH = 10 (HRT : 6hr) was 27.8%. For the disturbance plate reactor COD removal efficiency in the pH = 4 (HRT : 6Min.) was 86.5%, COD removal efficiency in the pH =7 (HRT : 6Min.) was 84.4%, and COD removal efficiency in the pH = 10 (HRT : 60Min.) was 86.8%. For the packed-bed reactor COD removal efficiency in the pH = 4 (HRT : 40Min.) was 76.0%, COD removal efficiency in the pH = 7 (HRT : 40Min.) was 81.3%, and COD removal efficiency in the pH = 10 (HRT : 40Min.) was 84.6%. After O3 treatment using possible by-product(Na2SO4) was 150g/ℓ.

  • PDF

The Relationship between Hormone Replacement Therapy and Periodontal Disease in Postmenopausal Women

  • Ahn, Eunsuk;Lee, Yunhee
    • Journal of dental hygiene science
    • /
    • v.18 no.1
    • /
    • pp.9-17
    • /
    • 2018
  • The purpose of this study was to investigate the relationship between hormone replacement therapy (HRT) and periodontal disease in postmenopausal women using data from the 4th and 5th Korea National Health and Nutrition Examination Survey. A total of 5,482 postmenopausal women aged 45~75 years were included as study subjects in the final analysis. The HRT group comprised 1,035 postmenopausal women who had received HRT for at least one month, and the non-HRT group comprised 4,447 postmenopausal women who did not receive HRT. The chi-square test was used to confirm the bivariate relationship between the variables. Multinomial logistic regression analysis was used to adjust for covariance (age, education, family income, body mass index, age of menopause, alcohol, smoking, dental visit <1 per year, use of oral care products, and frequency of tooth brushing per day). After adjusting for all covariates, HRT was found to be associated with periodontal disease. In particular, the relationship between HRT and periodontal disease was more evident in older women and women younger than 45 years of menopausal age. The relationship between HRT and periodontal disease was stronger in women who brushed their teeth less than 3 times per day, women without regular oral examination, and women who did not use oral hygiene products. The results of this study confirmed the importance of actively considering hormone therapy when determining policy recommendations for postmenopausal women. Especially, health programs such as HRT, regular dental examination, and oral care are needed for older women who have undergone premature menopause.

Greenhouse gases emission from aerobic methanotrophic denitrification (AeOM-D) in sequencing batch reactor

  • Lee, Kwanhyoung;Choi, Oh Kyung;Lee, Jae Woo
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.171-184
    • /
    • 2017
  • This study presents the effect of hydraulic retention time (HRT) on the characteristics of emission of three major greenhouse gases (GHGs) including $CH_4$, $CO_2$ and $N_2O$ during operation of a sequencing batch reactor for aerobic oxidation of methane with denitrification (AeOM-D SBR). Dissolved $N_2O$ concentration increased, leveled-off and slightly decreased as the HRT increased from 0.25 to 1d. Concentration of the dissolved $N_2O$ was higher at the shorter HRT, which was highly associated with the lowered C/N ratio. A longer HRT resulted in a higher C/N ratio with a sufficient carbon source produced by methanotrophs via methane oxidation, which provided a favorable condition for reducing $N_2O$ formation. With a less formation of the dissolved $N_2O$, $N_2O$ emission rate was lower at a longer HRT condition due to the lower C/N ratio. Opposite to the $N_2O$ emission, emission rates of $CH_4$ and $CO_2$ were higher at a longer HRT. Longer HRT resulted in the greater total GHGs emission as $CO_2$ equivalent which was doubled when the HRT increased from 0.5d to 1.0 d. Contribution of $CH_4$ onto the total GHGs emission was most dominant accounting for 98 - 99% compared to that of $N_2O$ (< 2%).

Factors of Intention to take Hormone Replacement therapy in korean Menopausal Women (폐경기 여성의 호르몬 대체요법 선택의도에 영향을 미치는 요인)

  • Chung, Chae-Weon
    • Women's Health Nursing
    • /
    • v.9 no.4
    • /
    • pp.369-378
    • /
    • 2003
  • Purpose: To identify factors influencing women's intention to take hormone replacement therapy(HRT). Method: A cross-sectional survey design was utilized. A total of 116 married women aged 40 to 60 were recruited from women's groups in communities. They completed a structured questionnaire containing demographic characteristics, Orientation to Life Questionnaire, Menopausal Symptom Checklist, Health Belief of Korean Adult, Sexrole Idea of Kim, Dong-il, chronic illnesses, and a single item measuring marital satisfaction. Result: Thirteen percents of the women were currently taking HRT and 28.4% had intention to take HRT. Education, sense of coherence, and sex role attitude were related to women's susceptibility to menopause. Hysterectomy status and the level of sense of coherence explained women's perception of seriousness regarding menopause. In addition, chronic health conditions accounted for the variances of benefits and barriers to HRT. Factors influencing women's intention to take HRT were education, menopausal symptoms, and perceived benefits of HRT. Conclusion: Women's chronic health conditions, psychosocial characteristics as well as menopausal discomforts were associated with women's choice regarding HRT. Other factors related to decision making process of women's health seeking behaviors need to be explored.

  • PDF

Improvement of Organics and Nitrogen Removal by HRT and Recycling Rate in Air Lift Reactors (공기부상반응조에서 체류시간과 반송율에 의한 유기물질 및 질소제거 향상에 관한 연구)

  • Kim, Jin-Ki;Yu, Sung-Whan;Lim, Bong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 2006
  • This study was performed to evaluate the air lift reactors (ALR) by variations of HRT and recycling rate. Air lift reactor was composed of bioreactor and clarifier above it. To remove organic matters and nitrogen through the formation of microbic film and filtration, bio-filter reactors were filled with clay, glass, bead, waste plastic, respectively. Influent wastewater was fed to biofilter reactor, and effluent wastewater from bio-filter reactor was injected ALR again, instead of adding external carbon source. Effluent BOD concentration was satisfied with lower than 10 mg/L in recycling rate 100% regardless of the variation of HRT and the kinds of media materials. In HRT 4 hr, recycling rate 100%, BOD removal efficiency rate was from about 85 to 90%, COD removal efficiency rate was higher than 90%. Effluent TN concentration was satisfied with less than 20 mg/L, if HRT was maintained by over than 6 hr regardless of recycling rate and media materials. Over than HRT was 4 hr, microbes concentration in air lift reactor was maintained over than 2,500 mg/L constantly, not sensitive to environmental condition, and organic removal was effective as it was higher.

Menopausal Symptoms and Quality of Life according to Hormone Replacement Therapy in Rural Postmenopausal Women (농촌지역 폐경여성의 호르몬요법에 따른 폐경증상과 삶의 질)

  • Kim, Young-Ji;Kim, Keum-Soon;Kim, Jeong-Sig
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2013
  • Purpose: This study was conducted to identify menopausal symptoms and quality of life (QOL) according to hormone replacement therapy (HRT) in rural menopausal women. Methods: Menopausal symptoms and QOL were measured by questionnaires. A total of 50 participants in HRT group had received hormone replacement therapy for 12 weeks and another 50 who had not received hormone therapy were assigned to non-HRT group. Results: Vasomotor symptom score of non-HRT group was significantly higher than that of HRT group (p=.013). There were no statistically significant differences between two groups in all menopausal symptoms except for vasomotor symptom. There were no significant differences between two groups in the total scores and sub-scores of QOL. Total scores and sub-scores of QOL were very low in both group. Menopausal symptoms were significantly negatively correlated with QOL. Conclusion: These results showed that there were no statistically significant differences between HRT group and non-HRT group in menopausal symptoms except for vasomotor symptom and QOL. Menopausal symptoms were moderate and QOL was very low in menopausal women. It is necessary to develop nursing interventions to improve menopausal symptoms and QOL in menopausal women.

Effects of Different Hydraulic Retention Times on Contaminant Removal Efficiency Using Aerobic Granular Sludge (HRT 변경에 따른 호기성 그래뉼 슬러지의 오염원 제거효율에 미치는 영향)

  • Kim, Hyun-Gu;Ahn, Dae-Hee
    • Journal of Environmental Science International
    • /
    • v.28 no.8
    • /
    • pp.669-676
    • /
    • 2019
  • The purpose of this study was to evaluate the effects of different Hydraulic Retention Times (HRTs) on the contaminant removal efficiency using Aerobic Granular Sludge (AGS). A laboratory-scale experiment was performed using a sequencing batch reactor, and the Chemical Oxygen Demand (COD), nitrogen, orthophosphate removal efficiency, AGS/MLSS ratio, and precipitability in accordance with the HRT were evaluated. As a result, the COD removal efficiency was not significantly different with the reduction in HRT, and at a HRT of 6 h, the removal rate was slightly increased owing to the increase in organic loading rate. The nitrogen removal efficiency was improved by injection of influent division at a HRT of 6 h. As the HRT decreased, the MLSS and AGS tended to increase, and the sludge volume index finally decreased to 50 mL/g. In addition, the size of the AGS gradually increased to about 1.0 mm. Therefore, the control of HRT provides favorable conditions for the stable formation of AGS, and is expected to improve the contaminant removal efficiency with the selection of a proper operation strategy.

Nitrite Accumulation Characteristics According to Hydraulic Retention Time and Aeration Rate in a Biological Aerated Filter (생물여과 반응기에서 수리학적 체류시간 및 폭기량에 따른 아질산 축적 특성)

  • Yoon, Jong Moon;Kim, Dong Jin;Yoo, Ik-Keun
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.200-206
    • /
    • 2006
  • In a biological aerated filter (BAF) packed with ceramic media (void fraction of BAF=0.32), nitrite accumulation was studied with the variation of hydraulic retention time (HRT) and superficial air velocity. Synthetic ammonium wastewater and petrochemical wastewater were fed at a constant load of $1.6kgNH_4^+-N/m^3{\cdot}d$. Ammonium removal rate was mainly affected by the superficial air velocity in BAF, but nitrite ratio($NO_2-N/NO_x-N$) in the effluent was dependent on both HRT and superficial air velocity. For a fixed HRT of 0.23 hr (corresponding to the empty bed contact time of 0.7 hr) ammonium removal rate was 73/90/92% and nitrite ratio was 0.92/0.82/0.48 at the superficial air velocity of 0.23/0.45/0.56 cm/s, respectively. When HRT is increased to 0.9 hr with superficial air velocity ranging from 0.34 to 0.45 cm/s, the ammonium removal rate was 89% on average. However nitrite ratio decreased significantly down to 0.13. When HRT was further increased to 1.4 hr, ammonium removal rate decreased, thereby resulting in the free ammonia ($NH_3-N$, FA) build-up and nitrite ratio gradually increased (>0.95). Although aeration rate and FA concentration at HRT of 0.23 hr were unfavorable for nitrite accumulation compared with those at HRT of 0.9 hr, nitrite ratio at HRT of 0.23 hr was higher. Taken together, HRT and nitrogen load were found to be critical, in addition to FA concentration and aeration condition, for nitrite accumulation in the BAF tested in the present study.