• 제목/요약/키워드: HRSG

검색결과 80건 처리시간 0.026초

관류형 증기발생기를 사용한 복합발전용 초임계압 하부시스템의 성능 설계해석 (Performance Design Analysis of the Supercritical Pressure Bottoming System of Combined Cycle Power Plants Using Once-Through Steam Generator)

  • 양진식;김동섭;노승탁
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1370-1377
    • /
    • 2002
  • This study analyzed the design performance of the bottoming system of combined cycle power plants using a once-through heat recovery steam generator. For a parallel arrangement of the main heater and reheater, parametric analyses were carried out to present the criteria for determining the reheater pressure and the location of the starting point of the reheater in the HRSG. The performance of the bottoming system was presented fer a range from high subcritical to supercritical pressure. The steam turbine power is as high as that of conventional triple-pressure bottoming systems. The serial arrangement of heat exchangers with division of each heater into several segments can achieve similar power level.

관류형 열회수 증기발생기와 증기터빈 시스템의 성능해석 (Performance Analysis of Once-through HRSG and Steam Turbine System)

  • 양진식;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.872-877
    • /
    • 2001
  • This study analyzed the design performance of the bottoming system of combined cycle power plants adopting a single-pressure once-through heat recovery steam generator with reheat. A computer program was constructed and parametric analyses were carried out to present the criteria for determining the reheat pressure and the location of the starring point of the reheater in the HRSG. The performance of the bottoming system was presented for the range from high subcritical to supercritical pressures. It was founded that the power of the bottoming system can be as high as that of the present triple-pressure bottoming system even with a higher exhaust gas temperature. A requirement for this high performance is a proper arrangement of the reheater.

  • PDF

가스터빈 복합 열병합 발전의 최적 운전조건에 관한 연구 (A Study for the Optimal Operating Conditions of the Gas Turbine Based Combined Cycle Cogeneration Power Plant)

  • 조영빈;손정락;노승탁
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1582-1590
    • /
    • 2004
  • The purpose of this study is to show the existence of optimal operation conditions for minimum fuel consumption of the gas turbine based combined cycle cogeneration power plant. Optimal operational condition means the optimal distribution of the power generated by each gas turbine and the heat generated by each HRSG. Total fuel consumption is calculated by the sum of the fuels for gas turbines and supplementary boiler. Fuel consumption is calculated by numerical methods of energy equations which contain the power generated from gas and steam turbines, the heat generated by HRSG and the heat extracted from high pressure steam turbine.

암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절 (pH Control of Feed Water for HRSG with Additional Injection of NH3)

  • 목용강;문승재;이재헌
    • 플랜트 저널
    • /
    • 제11권2호
    • /
    • pp.32-38
    • /
    • 2015
  • 탈기기-저압드럼 일체형 배열회수보일러로 구성된 복합화력발전소에서 발생한 저압증기발생기의 튜브파손 사례를 관찰하였다. 수소이온농도 변화를 관찰한 결과 복수펌프 후단에 주입된 암모니아가 탈기기를 통과한 후 저압 드럼 내에서 암모니아 분배율에 따라 증기와 함께 다량의 암모니아가 소모되어 급수 내 수소이온농도 저하를 확인하였다. 이를 해결하기 위해 저압드럼 내에 암모니아를 직접 주입할 수 있도록 추가 주입위치를 선정하였으며 적정량의 암모니아 용액을 주입함으로써 보일러 급수의 최적 수소이온농도인 9.2~9.6 으로 조절이 가능하다는 결론을 얻었다.

  • PDF

복합열병합발전소에 적용된 유기랭킨사이클의 성능 및 경제성 평가 (Evaluation of Performance and Economics of Organic Rankine Cycle Integrated into Combined Cycle Cogeneration Plant)

  • 김인섭;김창민;김동섭;이종준
    • 한국유체기계학회 논문집
    • /
    • 제20권1호
    • /
    • pp.41-47
    • /
    • 2017
  • This study aimed to analyze organic Rankine cycle(ORC) which recovers discarded heat from a gas turbine based combined cycle cogeneration(CC-cogen) plant in terms of both performance and economics. The nominal electric power of the CC-cogen plant is around $120MW_e$, and heat for district heating is $153MW_{th}$. The major purpose of this study is to compare various options in selecting heat source of the ORC. Three heat sources were compared. Case 1 uses the exhaust gas from the HRSG, which is purely wasted to environment in normal plant operation without ORC. Case 2 also uses the exhaust gas from the HRSG. On the other hand, in this case, the DH economizer, which is located at the end of the HRSG, does not operate. Case 3 generates power using some of the district heating water which is supplied to consumers. The estimated ORC power generation ranges between 0.3 to 2.3% of the power generation capacity of the CC-cogen plant. Overall, Case 3 is evaluated to be better than other two options in terms of system design flexibility and power generation capacity.

덕트 버너 추가에 따른 수직형 HRSG 내 화염 복사 열전달의 영향에 관한 연구 (Effect of Flame Radiative Heat Transfer in Horizontal-Type HRSG with Duct Burner)

  • 김대희;김승진;최상민;이봉재;김진일
    • 대한기계학회논문집B
    • /
    • 제37권2호
    • /
    • pp.197-204
    • /
    • 2013
  • 본 연구에서는 덕트 버너를 추가적으로 사용하는 수직형 배열회수 보일러(HRSG)에서 발생하게 되는 화염에 의한 전열면으로의 화염 복사 열전달에 의한 영향을 살펴보기 위한 해석 기법을 마련하였다. 덕트 버너 화염과 전열면은 가상의 평면으로 가정하였고, 화염 온도, 면적 및 방사율 입력정보는 간략화 하였다. 덕트버너 설치 위치 및 연료를 달리한 3 가지 해석 case 가 고려되었으며 계산된 화염 복사 열전달률과 열유속은 삼원자 가스 복사 및 대류 열전달과 비교되었다. 모든 해석 case 에서 삼원자 가스복사 열전달에 의한 영향은 미미하였고, 전열면에서 대류 열전달 대비 화염 복사 열전달률은 8~41%인 것으로 나타났다. 이 연구에서 얻은 중요한 사실은 화염 복사가 집중되는 전열면의 중앙부분에서 국부적인 열유속은 화염 복사에 의해 완전히 지배된다는 것이다.

수평형 폐열회수보일러 배기탈질 SCR시스템의 최적설계를 위한 수치해석적 연구 (Numerical Study on Optimization of the SCR Process Design in Horizontal HRSG for NOx Reduction)

  • 김경숙;이경옥
    • 한국환경과학회지
    • /
    • 제22권11호
    • /
    • pp.1481-1498
    • /
    • 2013
  • The SCR (selective catalytic reduction) system is highly-effective technique for NOx reduction from exhaust gases. In this study, the effects of the direction and size of nozzle and the ammonia injection concentration on the performance of SCR system are analyzed by using the computational fluid dynamics method. When the nozzle is arranged in zigzaged direction which is normal to exhausted gas flow, it is shown that the uniformity of gas flow and the NH3/NO molar ratio is improved remarkably. With the change of the ammonia injection concentration from 0.2 vol%(wet) to 1.0 vol%(wet), the uniformity of gas flow shows a good results. As the size of nozzle diameter changes from 6 mm to 12 mm, the uniformity of gas flow is maintained well. It is shown that the uniformity of the $NH_3/NO$ molar ratio becomes better with decreasing the ammonia injection concentration and the size of nozzle diameter.

열병합 복합발전시스템용 폐열회수 보일러 열설계 소프트웨어 개발 연구 (Development of a Thermal Design Software for the Heat Recovery Steam Generator of Combined Cogeneration Systems)

  • 김태국;오시덕;권용호;서석호;김백영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.726-731
    • /
    • 2001
  • A thermal design software is developed for the heat recovery steam generator(HRSG) of combined cogeneration systems. The heat transfer is calculated by using the element method to account for the varying thermal properties across the heat transfer elements. The circulation balance is computed for the evaporator to accurately estimate the steam generation rate and to check the proper circulation of the boiler water through the tubes. The software developed can be used to simulate HRSG systems with various combinations of auxiliary burner, wall superheater, superheater, reheater, evaporator, and economizer. Systems with several different combinations of the system components are successfully tested. And it is concluded that the developed software can be used for the design of heat recovery steam generators with various combinations of heat transfer components.

  • PDF

가스터빈 결빙방지 시스템이 복합화력발전 시스템의 성능에 미치는 영향 (Analysis of the Influence of Anti-icing System on the Performance of Combined Cycle Power Plants)

  • 문성원;김정호;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제19권6호
    • /
    • pp.19-25
    • /
    • 2016
  • Anti-icing is important in gas turbines because ice formation on compressor inlet components, especially inlet guide vane, can cause performance degradation and mechanical damages. In general, the compressor bleeding anti-icing system that supplies hot air extracted from the compressor discharge to the engine intake has been used. However, this scheme causes considerable performance drop of gas turbines. A new method is proposed in this study for the anti-icing in combined cycle power plants(CCPP). It is a heat exchange heating method, which utilizes heat sources from the heat recovery steam generator(HRSG). We selected several options for the heat sources such as steam, hot water and exhaust gas. Performance reductions of the CCPP by the various options as well as the usual compressor bleeding method were comparatively analyzed. The results show that the heat exchange heating system would cause a lower performance decrease than the compressor bleeding anti-icing system. Especially, the option of using low pressure hot water is expected to provide the lowest performance reduction.

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.