Abstract
The purpose of this study is to show the existence of optimal operation conditions for minimum fuel consumption of the gas turbine based combined cycle cogeneration power plant. Optimal operational condition means the optimal distribution of the power generated by each gas turbine and the heat generated by each HRSG. Total fuel consumption is calculated by the sum of the fuels for gas turbines and supplementary boiler. Fuel consumption is calculated by numerical methods of energy equations which contain the power generated from gas and steam turbines, the heat generated by HRSG and the heat extracted from high pressure steam turbine.
Keywords
Combined Cycle Cogeneration; Optimal Operational Condition; Fuel Consumption; Power Load; Heat Load;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kim, S. J. and Ro, S. T., 1997, 'The Performance Analysis of a Single and Dual Pressure HRSG,' Proceeding of the KSME Spring Annual Meeting B, pp. 7-12
2 Yokoyama, R., Ito, K. and Matsumoto, Y., 1991, 'Optimal Sizing of a Gas Turbine Cogeneration Plant in Consideration of Its Operational Strategy,' ASME COGEN-TURBO, IGTI, Vol. 6, pp. 363-370
3 Gyarmathy, G., 1989, 'On Load Control Methods for Combined Cycle Plants,' ASME COGEN-TURBO, IGTI, Vol. 6, pp. 39-50
4 Kim, T. S., 1995, 'Design and Performance Analysis of Gas Turbines with Applications to Cogeneration Systems,' Ph. D. Thesis, Seoul National University
5 Kim, J. H., 2000, 'Analysis on Transient Behavior of Gas Turbines for Power Generation,' Ph. D. Thesis, Seoul National University
6 Ito, K., Yokoyama, R., Akagi, S. and Matsumoto, Y., 1990, 'Influence of Fuel Cost on the Operation of a Gas Turbine-Waste Heat Boiler Cogeneration Plant,' Transactions of the ASME, Journal of Engineering for Gas Turbine and Power, Vol. 112, pp. 122-128   DOI