• Title/Summary/Keyword: HPTS

Search Result 16, Processing Time 0.019 seconds

Characteristic of InP/InGaAs HBT for Long Wavelength Application (장파장 응용을 위한 InP/InGaAs HBT의 광특성)

  • 김강대;허영헌;박재홍;김용규;문태정;황성범;송정근
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1073-1076
    • /
    • 2003
  • This paper shows the performance as a photodetector of InP/InGaAs HPT operated with a base bias and forntside optical injection through the emitter. InP/InGaAs HPT produced the high optical gain of about 16.2 where HPT is biased at Vc=1V, I$_{B}$=20$\mu$A with an input optical power of 2.4$\mu$W. And we examined that the optical gain of HPTs becomes larger when operating in 3-terminal configuration rather than 2-terminal with the floating base. The optical performance of InP/InGaAs HPT is an attractive to the PIN Photodetector for use in long wavelength optical receivers.s.

  • PDF

An Efficient Current-Voltage Model for the AlGaAs/GaAs N-P Heterojunction Diode and its Application to HPTs

  • Park, Jae-Hong;Kwack, Kae-Dal
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.99-105
    • /
    • 1997
  • The new classified model for N-p heterojunction diode is derived and used extensively in analyzing the current-voltage(I-V) characteristics of the HBTs. A new classification method is presented in order to simplify I-V equations and easily applied to the modeling of HBTs. This classification method is characterized by the properties of devices such as high level injection, the thickness of one or both bulk regions, the surface recombination and the generation-recombination. The simulation results using the proposed model agree well with the experimentally observed I-V behaviors and show good efficiencies in its application to HBTs with respect to mathematical formulation.

  • PDF

Study on Online Monitoring of Dissolved Oxygen, pH and Cell Concentration in E. coli Cultivation Processes Using MABOOMSTM (마이크로플레이트 기반 생물반응기 시스템 (MABOOMSTM)을 이용한 대장균 배양공정에서 용존산소, pH 및 세포농도의 온라인 모니터링 연구)

  • Sohn, Ok-Jae;Rhee, Jong Il
    • KSBB Journal
    • /
    • v.28 no.1
    • /
    • pp.24-30
    • /
    • 2013
  • Dissolved oxygen, pH and cell concentration have been online monitored in cultivation processes with Escherichia coli by using a $MABOOMS^{TM}$ (microplate-based bioreactor with optical online monitoring systems). Fluorescent sensing membranes containing Ru ${(dpp)_3}^{2+}$ or HPTS were prepared with GA sol-gel matrix and coated into a well of a 24-well microplate. Fluorescence intensity was measured and correlated to the dissolved oxygen or pH. Cell concentrations were also online monitored by measuring optical reflectance at 650 nm. A well of a 24-well microplate could also be divided into 4 parts, each of which was coated with fluorescent sensing membranes for the detection of dissolved oxygen or pH. The 24-well microplate coated with fluorescent sensing membranes or a 4-divided sensing membrane. was used to online monitor the dissolved oxygen, pH and cell concentration during E. coli cultivations. The online monitoring results showed the characteristics of cell growth in cultivation processes very well.

Characterization of Double-layer Optical Sensing Membranes for Dual Sensing of Dissolved Oxygen Concentrations and pH and Their Application to the On-line Monitoring of Fermentation Processes (용존산소농도와 pH의 동시 검출용 이중층 광학 센서막의 특성 및 발효공정의 온라인 모니터링에의 응용)

  • Kim, Chun-Kwang;Lee, Jong-Il
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • A double-layer optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen (DO) and pH value simultaneously. (tris(4,7-diphenyl-1,10-phenanthroline (Rudpp) ruthenium(II)) as a DO sensitive dye has been mixed in the methyl trimethoxy silane (MTMS) sol-gel solution and coated onto one well in a 24-well microtiter plate. On the DO-sensing layer the GA (3-glycidoxypropyl trimethoxy silane (GPTMS), 3-aminopropyl trimethoxy silane (APTMS)) sol-gel solution mixed with 8-hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (HPTS) has been coated and used to measure pH values. The double-layer sensing membrane was affected by ionic strength and temperature. The double-layer sensing membrane for DO and pH has been applied to online monitor in microorganism cultivation processes and showed a good performance.

Characteristics and Fabrication of Dissolved Oxygen and pH Measurement System based on the Optical Sensor for Analysis of Cell Metabolic Functions (세포대사 기능 분석을 위한 광학센서 기반 용존산소와 pH 측정 시스템의 제작 및 특성 분석)

  • Jang, Jiwoon;Hwang, Insook;Lee, Jongmok;Lee, Sunmin;Kang, Sora;Kim Pak, Youngmi;Kim, Nayoung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.51-56
    • /
    • 2016
  • This study evaluates the performance of an optical sensor and measurement system (CMA-24) which can analyze the fluctuation of dissolved oxygen and pH simultaneously. In the optical sensor system, the fluorescent materials, Rudpp and HPTS which are sensitive to dissolved oxygen and pH, respectively, are coated on the bottom of a 24-well -plate by the sol-gel technology. The detection times of the emission light of the oxygen sensor were $4,186{\pm}13.90{\mu}s$ and $4,452{\pm}36.68{\mu}s$ for the dissolved oxygen of 17% $O_2$ and 7.6% $O_2$, respectively. On the other hand, the detection times of the pH sensor were $6,699.43{\pm}14.64{\mu}s$, $6,722.24{\pm}6.21{\mu}s$, and $6,748.52{\pm}2.63{\mu}s$ using pH 6, 7, and 8, respectively. When we determined cellular respiration levels of C2C12 myocytes with CMA-24, $O_2$/pH measurement system, the ratio of the uncoupled to coupled OCR (oxygen consumption rate) was 1.41. The results mean that this CMA-24 system shows almost the same sensitiveness as the commercial system.

Stability Characteristics of Supercritical High-Pressure Turbines Depending on the Designs of Tilting Pad Journal Bearings

  • Lee, An Sung;Jang, Sun-Yong
    • Tribology and Lubricants
    • /
    • v.37 no.3
    • /
    • pp.99-105
    • /
    • 2021
  • In this study, for a high-pressure turbine (HPT) of 800 MW class supercritical thermal-power plant, considering aerodynamic cross-coupling, we performed a rotordynamic logarithmic decrement (LogDec) stability analysis with various tilting pad journal bearing (TPJB) designs, which several steam turbine OEMs (original equipment manufacturers) currently apply in their supercritical and ultra-supercritical HPTs. We considered the following TPJB designs: 6-Pad load on pad (LOP)/load between pad (LBP), 5-Pad LOP/LBP, Hybrid 3-Pad LOP (lower 3-Pad tilting and upper 1-Pad fixed), and 5-Pad LBPs with the design variables of offset and preload. We used the API Level-I method for a LogDec stability analysis. Following results are summarized only in a standpoint of LogDec stability. The Hybrid 3-Pad LOP TPJBs most excellently outperform all the other TPJBs over nearly a full range of cross-coupled stiffness. In a high range of cross-coupled stiffness, both the 6-Pad LOP and 5-Pad LOP TPJBs may be recommended as a practical conservative bearing design approach for enhancing a rotordynamic stability of the HPT. As expected, in a high range of cross-coupled stiffness, the 6-Pad LBP TPJBs exhibit a better performance than the 5-Pad LBP TPJBs. However, contrary to one's expectation, notably, the 5-Pad LOP TPJBs exhibit a slightly better performance than the 6-Pad LOP TPJBs. Furthermore, we do not recommend any TPJB design efforts of either increasing a pad offset from 0.5 or a pad preload from 0 for the HPT in a standpoint of stability.