• 제목/요약/키워드: HPGe

검색결과 149건 처리시간 0.021초

Evaluation of gamma-ray and neutron attenuation properties of some polymers

  • Kacal, M.R.;Akman, F.;Sayyed, M.I.;Akman, F.
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.818-824
    • /
    • 2019
  • In the present work, we determined the gamma-ray attenuation characteristics of eight different polymers(Polyamide (Nylon 6) (PA-6), polyacrylonitrile (PAN), polyvinylidenechloride (PVDC), polyaniline (PANI), polyethyleneterephthalate (PET), polyphenylenesulfide (PPS), polypyrrole (PPy) and polytetrafluoroethylene (PTFE)) using transmission geometry utilizing the high resolution HPGe detector and different radioactive sources in the energy range 81-1333 keV. The experimental linear attenuation coefficient values are compared with theoretical data (WinXCOM data). The linear attenuation coefficient of all polymers reduced quickly with the increase in energy, at the beginning, while decrease more slowly in the region from 267 keV to 835 keV. The effective atomic number of PVDC and PTFE are comparatively higher than the $Z_{eff}$ of the remaining polymers, while PA-6 possesses the lowest effective atomic number. The half value layer results showed that PTFE ($C_2F_4$, highest density) is more effective to attenuate the gamma photons. Also, the theoretical results of macroscopic effective removal cross section for fast neutrons ($\sum_{R}$) were computed to investigate the neutron attenuation characteristics. It is found that the $\sum_{R}$ values of the eight investigated polymers are close and ranged from $0.07058cm^{-1}$ for PVDC to $0.11510cm^{-1}$ for PA-6.

Determination of indoor doses and excess lifetime cancer risks caused by building materials containing natural radionuclides in Malaysia

  • Abdullahi, Shittu;Ismail, Aznan Fazli;Samat, Supian
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.325-336
    • /
    • 2019
  • The activity concentrations of $^{226}Ra$, $^{232}Th$, and $^{40}K$ from 102 building materials samples were determined using a high-purity germanium (HPGe) detector. The activity concentrations were evaluated for possible radiological hazards to the human health. The excess lifetime cancer risks (ELCR) were also estimated, and the average values were recorded as $0.42{\pm}0.24{\times}10^{-3}$, $3.22{\pm}1.83{\times}10^{-3}$, and $3.65{\pm}1.85{\times}10^{-3}$ for outdoor, indoor, and total ELCR respectively. The activity concentrations were further subjected to RESRAD-BUILD computer code to evaluate the long-term radiation exposure to a dweller. The indoor doses were assessed from zero up to 70 years. The simulation results were $92{\pm}59$, $689{\pm}566$, and $782{\pm}569{\mu}Sv\;y^{-1}$ for indoor external, internal, and total effective dose equivalent (TEDE) respectively. The results reported were all below the recommended maximum values. Therefore, the radiological hazards attributed to building materials under study are negligible.

Experimental setup for elemental analysis using prompt gamma rays at research reactor IBR-2

  • Hramco, C.;Turlybekuly, K.;Borzakov, S.B.;Gundorin, N.A.;Lychagin, E.V.;Nehaev, G.V.;Muzychka, A. Yu;Strelkov, A.V.;Teymurov, E.
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2999-3005
    • /
    • 2022
  • The new experimental setup has been built at the 11b channel of the IBR-2 research reactor at FLNP, JINR, to study the elemental composition of samples by registration of prompt gamma emission during thermal neutron capture. The setup consists of a curved mirror neutron guide and a radiation-resistant HPGe high-purity germanium detector. The detector is surrounded by lead shielding to suppress the natural background gamma level. The sample is placed in a vacuum channel and surrounded by a LiF shield to suppress the gamma background generated by scattered neutrons. This work presents characteristics of the experimental setup. An example of hydrogen concentration determining in a diamond powder made by detonation synthesis is given and on its basis, the sensitivity of the setup is calculated being ~4 ㎍.

Effects of element composition in soil samples on the efficiencies of gamma energy peaks evaluated by the MCNP5 code

  • Ba, Vu Ngoc;Thien, Bui Ngoc;Loan, Truong Thi Hong
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.337-343
    • /
    • 2021
  • In this work, self-absorption correction factor related to the variation of the composition and the density of soil samples were evaluated using the p-type HPGe detector. The validated MCNP5 simulation model of this detector was used to evaluate its Full Energy Peak Efficiency (FEPE) under the variation of the composition and the density of the analysed samples. The results indicates that FEPE calculation of low gamma ray is affected by the composition and the density of soil samples. The self-absorption correction factors for different gamma-ray energies which was fitted as a function of FEPEs via density and energy and fitting parameters as polynomial function for the logarithm neper of gamma ray energy help to calculate quickly the detection efficiency of detector. Factor Analysis for the influence of the element composition in analysed samples on the FEPE indicates the FEPE distribution changes from non-metal to metal groups when the gamma ray energy increases from 92 keV to 238 keV. At energies above 238 keV, the FEPE primarily depends only on the metal elements and is significantly affected by aluminium and silicon composition in soil samples.

Database of virtual spectrum of artificial radionuclides for education and training in in-situ gamma spectrometry

  • Yoomi Choi;Young-Yong Ji;Sungyeop Joung
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.190-200
    • /
    • 2023
  • As the field of application of in-situ gamma spectroscopy is diversified, proficiency is required for consistent and accurate analysis. In this study, a program was developed to virtually create gamma energy spectra of artificial nuclides, which are difficult to obtain through actual measurements, for training. The virtual spectrum was created by synthesizing the spectra of the background radiation obtained through actual measurement and the theoretical spectra of the artificial radionuclides obtained by a Monte Carlo simulation. Since the theoretical spectrum can only be obtained for a given geometrical structure, representative major geometries for in-situ measurement (ground surface, concrete wall, radioactive waste drum) and the detectors (HPGe, NaI(Tl), LaBr3(Ce)) were predetermined. Generated virtual spectra were verified in terms of validity and harmonization by gamma spectrometry and energy calibration. As a result, it was confirmed that the energy calibration results including the peaks of the measured spectrum and the peaks of the theoretical spectrum showed differences of less than 1 keV from the actual energies, and that the calculated radioactivity showed a difference within 20% from the actual inputted radioactivity. The verified data were assembled into a database and a program that can generate a virtual spectrum of desired condition was developed.

Design and optimization of thermal neutron activation device based on 5 MeV electron linear accelerator

  • Mahnoush Masoumi;S. Farhad Masoudi;Faezeh Rahmani
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4246-4251
    • /
    • 2023
  • The optimized design of a Neutron Activation Analysis (NAA) system, including Delayed Gamma NAA (DGNAA) and Prompt Gamma NAA (PGNAA), has been proposed in this research based on Mevex Linac with 5 MeV electron energy and 50 kW power as a neutron source. Based on the MCNPX 2.6 simulation, the optimized configuration contains; tungsten as an electron-photon converter, BeO as a photoneutron target, BeD2 and plexiglass as moderators, and graphite as a reflector and collimator, as well as lead as a gamma shield. The obtained thermal neutron flux at the beam port is equal to 2.06 × 109 (# /cm2.s). In addition, using the optimized neutron beam, the detection limit has been calculated for some elements such as H-1, B-10, Na-23, Al-27, and Ti-48. The HPGe Coaxial detector has been used to measure gamma rays emitted by nuclides in the sample. By the results, the proposed system can be an appropriate solution to measure the concentration and toxicity of elements in different samples such as food, soil, and plant samples.

Assessment of radioactivity levels and radiation hazards in building materials in Egypt

  • Ahmed E. Abdel Gawad;Mohamed Y. Hanfi;Mostafa N. Tawfik;Mohammed S. Alqahtani;Hamed I. Mira
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.707-714
    • /
    • 2024
  • Different degrees of natural radioactivity found in quartz can have negative consequences on health. Quartz vein along the investigated Abu Ramad area, Egypt, had its natural radioactivity assessed. The HPGe spectrometer was used to determine the role played by the radionuclides 238U, 232Th, and 40K in the gamma radiation that was emitted, and the results showed that these concentrations are 484.64 ± 288.4, 36.8 ± 13.1 and 772.2 ± 134.6 Bq kg-1 were higher than the corresponding reported global limits of 33, 45, and 412 Bq kg-1 for each radionuclide (238U, 232Th, and 40K). Among the radiological hazard parameters, the excess lifetime cancer risk (ELCR) is estimated and it's mean value of ELCR (1.2) is higher than the permissible limit of 0.00029. The relationship between the radionuclides and the associated radiological hazard characteristics was investigated based on multivariate statistical methods including Pearson correlation, principal component analysis (PCA), and hierarchical cluster analysis (HCA). According to statistical research, the radioactive risk of quartz is primarily caused by the 238U, 232Thand 40K. Finally, applying quartz to building materials would pose a significant risk to the public.

다목적 동시측정 장치 개발에 의한 원자핵 구조 연구(I) - $^{75}As$의 감마 전이에 대한 전자기적 특성 - (A Study on the Nuclear Structure through the Multipurpose Coincidence Measurement System Development ( I ) - The Electromagnetic Properties of the Gamma Transitions in $^{75}As$-)

  • 정원모;정갑수;주관식;나상균;황한열
    • Journal of Radiation Protection and Research
    • /
    • 제18권1호
    • /
    • pp.53-61
    • /
    • 1993
  • 홀수 핵종인 $^{75}As$의 핵 구조를 분광학적 방법으로 연구하기 위하여 $^{75}Se$의 전자 포획에 의하여 방출되는 감마선에 대해 단일 감마선 측정과 감마-감마 동시측정 실험을 하였다. 본 실험에서 구한 각 상관관계 계수는 $A_{22}=-0.452{\pm}0.017,\;A_{44}=0$이고 279.5keV 전이 감마선에 대한 혼합비는 ${\delta}=-0.586{\pm}0.017$을 얻었다. 또한 낮은 준위에서의 에너지의 상대 강도를 정확히 측정한 후 이를 이용하여 환산 행렬 요소들을 계산한 후 단일 입자 모형의 관점에서 hindrance factor를 구했다. 그 결과 279.5 keV 감마 전이의 다중극도는 74.44%의 Ml 전이와 25.56%의 E2 전이를 포함한 혼합 전이이며 5/2 준위의 밴드구조를 $f_{5/2}$ proton준위에 바탕을 둔 1/2 [310]으로 결정하였다.

  • PDF

Bed-type과 Stand-type 상용 전신계수기(Whole Body Counter)의 성능 비교 (Performance Comparison of Bed-type and Stand-type Commercial Whole Body Counter Made by Canberra for Internal Exposure Monitoring)

  • 김봉기;하위호;권태은;박민석;이준호;김종민;이상경;정규환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.437-444
    • /
    • 2018
  • Whole-Body counters have been used to evaluate the internal contamination of gamma emitting radionuclides. Among the whole-body counters used in domestic nuclear facilities, Fastscan made by CANBERRA contains 2 NaI(Tl) detectors and is generally used to monitor the primary internal exposure. It has the advantage of achieving MDA even with short time measurements. Accuscan is a bed type, and has good energy resolution because it is composed of HPGe detector. Since the Accuscan with better energy resolution than Fastscan has better able to identify radionuclides, it is used to monitor secondary internal exposure. Some nuclear facilities have only Fastscan. We analyzed statistically whether Fastscan is enough to ensure accuracy and precision comparing with Accuscan. To do this, we prepared a CRM created by the Korea Research Institute of Standards and Science. We also obtained the data of 6 Fastscans and 5 Accuscans in domestic nuclear facilities. As a result of the study, although Fastscan compared with Accuscan is not as accurate as the Accuscan, the precision is statistically same. However, accuracy of Fastscan is in compliance with international standards except low energy range. In terms of accuracy and precision except radionuclides emitting low energy, it is possible to measure radioactivity inside workers even in nuclear facilities where only Fastscan is used.

극저준위 백그라운드 감마선 측정시스템의 성능시험 (Performance Test of the Ultralow Background Gamma-Ray Measurement System)

  • 나원우;이영길
    • Journal of Radiation Protection and Research
    • /
    • 제22권3호
    • /
    • pp.219-226
    • /
    • 1997
  • 환경시료 및 Swipe시료에서 방출되는 감마선을 측정 분석하기 위하여 극저준위 백그라운드 감마선 측정시스템을 설치하였다. 본 측정시스템은 백그라운드를 저감하기 위해 극저방사능 물질로 구성된 수동적 차폐방법, 우주선 영향을 차단하기 위한 역동시 측정법, 그리고 공기중 방사성 핵종인 라돈가스를 시스템 내부에서 제거하는 방법 등을 적용하고 있다. 적용된 백그라운드 저감법에 대한 성능시험 결과, 실험실 조건의 백그라운드 준위가 관심 대상 에너지 영역($50\;keV{\sim}2\;MeV$)에서 $10^{-2}$ order 정도로 저감되었다. 그리고 미신고 핵활동을 탐지하기 위한 관심 대상 핵종의 감마선 에너지 영역에서 평가된 시스템의 최소검출하한(MDA)값은 환경시료 분석에 적합한 것으로 평가되었다. 그러나 저에너지 영역에서는 여전히 우주선에 의한 중성자 영향이 백그라운드 요인으로 작용하고 있는 것으로 분석되었다.

  • PDF