• Title/Summary/Keyword: HDS-K

Search Result 60, Processing Time 0.02 seconds

Design and Implementation of an IoT Device for the Effective Screening of Dementia and Mild Cognitive Impairment

  • Kim, Hansoo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.12
    • /
    • pp.119-126
    • /
    • 2019
  • Korea is rapidly becoming an aging society due to lower birth rate and longer life expectancy. As elderly diseases are of a serious concern, the number of patients with dementia has been increasing significantly. For now, it has become a nationwide problem, as dementia is difficult to manage and requires a lot of social costs. To solve this, an IoT device has been devised that efficiently screens Mild Cognitive Impairment(MCI), the early stage of dementia. To design and implement the device, the latest IoT technology is introduced, the optimized Korean Version of Hasegawa Dementia Scale Revised(K-HDS) is utilized, and convenient service scenario with user-friendly design is applied. As a result, the symptoms of MCI have been screened quickly with convenient operation, which lead to the healthier society by the prevention of dementia.

Agreement in self-other ratings of leader effectiveness: The role of dark side personality (팀 리더의 수행에 대한 자기-타인 평정간 비교 : 어두운 성격을 중심으로)

  • Kim, Myoung So;Han, Young Seok;Cho, Inchul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5497-5507
    • /
    • 2013
  • The purpose of this study was to investigate the effects of dark side personality traits on self-other rating agreement in leader effectiveness. Data were collected from 80 team leaders and their peers in college. Peers who conducted a team project were asked to assess performance of their team leaders on leader effectiveness, task performance, and contextual performance. The leaders were also asked to self-rate their performance on the same measures. Results indicated that there was disagreement of perceptions about personality traits between leader's self-ratings and the rating of others. First, leaders considered their own Bold, Diligent behaviors as positive influence on their leadership-related criteria, whereas peers of these leaders provided negative ratings. Also, leaders viewed Leisurely and Cautious characteristics as unrelated or negative to performance, whereas peers perceiveed these personality traits as positive to performance. Suggestions for future research were provided based on the findings.

4-Level Balanced Modulation Code for the Mitigation of Two-Dimensional Intersymbol Interference in Holographic Data-Storage Systems (홀로그래픽 데이터 저장장치에서 2차원 심볼 간 간섭을 완화하기 위한 4-레벨 균형 변조부호)

  • Park, Keunhwan;Lee, Jaejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.12-17
    • /
    • 2016
  • In the holographic data storage system (HDSS), the data regarding the volume of a storage medium are recorded and read by the page, and the transmission rate and storage capacity can be increased because of two-dimensional, page-oriented data processing; furthermore, the multi-level HDSS can store more than one bit per pixel. For this same reason, however, and unlike conventional data-storage systems, the HDSS is hampered by two-dimensional (2D) intersymbol interference (ISI) and interpage interference (IPI). Progress regarding the published papers on 2D ISI, which is more severe in the multi-level HDSS, continues; however, mitigation of both 2D ISI and IPI in terms of the multi-level HDSS has not yet been studied. In this paper, we therefore propose a 4-level balanced-modulation code that simultaneously mitigates 2D ISI and IPI.

Characterization of microsatellite markers covering chromosome 1 in the Korean and Japanese populations (한국인과 일본인에서 1번 염색체에 부착되는 microsatellite marker의 특징)

  • Lee, You-Jin;Park, Soo-Byung
    • The korean journal of orthodontics
    • /
    • v.34 no.6 s.107
    • /
    • pp.537-543
    • /
    • 2004
  • Microsatellit markers are considered to be very promising genetic markers for genetic linkage analysis. The majority of the markers are as informative as in Caucasians but there are significant ethnic differences in the genetic variations. In order to investigate the genetic variations in the Korean and Japanese populations and their ethnic differences, 51 microsatellite marker loci spanning the whole human chromosome 1 were arranged from a commercially available set (ABI PRISM Linkage Mapping Set-HD5, Applied Biosystems, Foster City, CA, USA), and then determined the allelic frequencies and heterozygosities for these marker loci in the 90 unrelated Korean subjects and 90 unrelated Japanese subjects. Of all 51 markers tested, significant differences were observed when microsatellite allele frequency pattern of Korean was compared with those of Caucasian, while this pattern was highly similar between Korean and Japanese populations. Our data indicate that an extensive verification of public microsatellite markers in a particular population study should be undertaken prior to their linkage studies. Moreover, this information should facilitate genetic linkage studies of various hereditary diseases, especially in the Koreans and Japanese.

Estimation of Humidifier Disinfectant Amounts Inhaled into the Respiratory System (가습기 살균제 피해자 호흡기로 흡입된 가습기 살균제 양 추정 - 호흡기 외부(external) 및 내부 노출(internal exposure) 추정 방법과 사례 -)

  • Park, Dong-Uk;Ryu, Seung-Hun;Lim, Heung-Kyu;Kim, Sun-Kyung;Roh, Hyun-Suk;Cha, Won-Seok;Park, Dooyong
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.3
    • /
    • pp.141-146
    • /
    • 2016
  • In South Korea, many cases of humidifier disinfectant-associated lung injury (HDLI) have been reported among people who used humidifier products containing humidifier disinfectant (HD). The objectives of this study are to estimate both airborne HD concentration in the room where HD was used and the amount of humidifier disinfectant absorbed into the respiratory system. Information and data on the HDs were collected using a structured questionnaire and home environmental investigations include the volume of HD (ml) and hours used per day, concentration of disinfectants contained in the HD brand (${\mu}g/ml$), volume of the room ($m^3$), assumed ventilation rate ($m^3/hr$) and breathing rate assumed ($m^3/hr$). We used children aged under five years old as a sample and estimated both airborne HD concentrations and amount of HD absorbed into the respiratory system. The estimated airborne concentration of HD in the room ranged from 68 to $369{\mu}g/m^3$ for PHMG (polyhexamethylene guanidine phosphate) and from 16 to $239{\mu}g/m^3$ for PGH (oligo (2-(2-ethoxy) ethoxyethyl guanidine). The amount of HD absorbed in the respiratory system per day was estimated to range from 227 to $1,225{\mu}g$ for PHMG and from 53 to $794{\mu}g$ for PGH. In conclusion, a great amount of HD was likely absorbed into respiratory system, likely beyond the level of the capacity of the immune system to remove the HD absorbed.

Review of Experimental Studies on Antithrombotic in Oriental Medicine -Within Articles in The Journal of Oriental Obstetrics & Gynecology Since 2001'- (국내 한의학계의 항혈전 효과에 대한 실험 연구 고찰 -2001년 이후 한방부인과학회지에 발표된 논문을 중심으로-)

  • Jung, Soo-Jung;Ma, Young-Hun;Choi, Seung-Bum;Park, Kyung-Mi
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.27 no.1
    • /
    • pp.152-166
    • /
    • 2014
  • Purpose: The purpose of this study is to compare with the result of experimental study about antithrombotic effect by reviewing recent oriental medicine journals that have been published since 2001' in Korea. Methods: Articles on antithrombotic effect that have been published from 2001' to 2013' in oriental medicine journals registered National Research Foundation of Korea were searched. After that, 12 articles using same 'thrombosis condition model' were selected and reviewed. Results: The results were as follows. 1. If there is no limit drug concentrations, platelet aggregation induced by adenosine diphosphate (ADP) in hyulbuchukeo-tanggamibang (HBCT) was the largest aggregation inhibitory effect and platelet aggregation induced by epinephrine in Saegeum-san (SGS), Jogan-tanggagambang (JGTG), hyulbuchukeo-tanggamibang (HBCT) had a large inhibitory effect on aggregation. 2. At the lowest concentration, Mokdan-san (MDS) of the inhibition of platelet aggregation induced by ADP and Hyunhosaik-san (HHS) of the inhibition of platelet aggregation induced by epinephrine were effective. 3. Pulmonary embolism induced by collagen and epinephrine in Neungasojeok-tang (NSJT) has the highest antithrombotic effect. 4. Pathological conditions of extravasated blood by dextran, Jogan-tanggagambang (JGTG) has the highest inhibitory effect on decrease in platelet numbers. Compared to the rest of the experimental drug, Saegeum-san (SGS), Heanggyonghonghwa-tang (HGTHHT), Wusl-san (WSS), Mokdan-san (MDS) showed significant inhibitory effect on the prothrombin time (PT) increases. Honghwadanggui-san (HDS), Saegeum-san (SGS) showed significant inhibitory effect on increase in activated partial thromboplastin time (APTT) and Jogan-tanggagambang (JGTG), Heanggyonghonghwa-tang (HGTHHT) showed significant inhibitory effect on decrease in fibrinogen. Conclusions: This result will provide useful information for the prescriptions of antithrombotic medicine in the field of Oriental medicine. We will have to carry out further studies that will compare each herb used in the diseases caused by extravasated blood.

Treatment of Nutrients Using the Upflow Vegetated Filter (상향류식 수초여과지를 이용한 영양염류처리)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1287-1292
    • /
    • 2006
  • Constructed wetlands are well known as highly efficient system to treat wastewater from different sources. Among the constructed wetlands, upflow types of constructed wetlands have become a common selection of wastewater during the last decade. We conducted a pilot scale study at peen house on treating potential of nutrients by upflow vegetated filter(UVF) pilot wetland which was combined with hydrodynamic separator and used the cattail plant(Typha angustifolia), and operated with artificial nutrients influent. This study evaluate the performances of upflow vegetated fille, in removal of nutrients. The objectives of this study were two-fold: (i) to evaluate the nutrients removal performance of pilot-scale upflow vegetated filter, filled with a mixture of perlite and soil media and planted with cattails and (ii) to design of scale-up upflow vegetated filter using Froude number. Results indicated that, under the condition of the ranges of hydraulic surface load rate were $22.7{\pm}9.6\;m^3/m^2/day$, the average removal of $COD_{Mn}$, and TN, TP were 57.5%, 40.0% and 41.5%, respectively. Computational fluid dynamics, FLUENT 6.0 program was used to predict the distribution of velocity in UVF and hydrodynamic separator. Full scale UVF was designed using the Froude number scale-up method that was assumed geomertic similarity between model and prototype. Result shows that the UVF with 3 m diameter has capacity of design sewage flowrate 75 $m^3/day$.

Is Compact Urban Spatial Structure Effective for Public Transportation Mode? (컴팩트형 공간구조가 대중교통수단의 이용활성화에 보다 효과적인가?)

  • Lee, Jae-Yeong;Kim, Hyung-Chul
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.3 s.74
    • /
    • pp.7-16
    • /
    • 2004
  • The purpose of this study was to find the characteristics of travel behavior and accessibility in terms of spatial structure. We analyzed travel behaviors and accessibility using a mode choice model and the Complementary Accessibility Index(CAI). The urban spatial structures that were compared were a compact city (CC) versus a sprawled city (SC), and high residential density districts (HD) versus low residential density districts (LD). First, CC and HDs residents had a shorter commuting distance than the CC and LDs residents. Second, behavior models showed that the use of Private cars for commuting in SCs was found to be greater than private car use in CCs, and that public transportation modes would be encouraged in CCs. Third, changes associated with the time and cost of commuting by private car generally affect the demand for public transportation modes in the CC. Also, analysis of cross elasticity suggests that changes of subway travel time affect the demand for buses very elastically. Fourth, the CAI of SC and LD were superior to the CC and HD even though the SC inefficient urban forms in terms of spatial structure. So, the spatial distribution of population density was also found to be an important factor affecting accessibility and energy savings.

Characteristics of Exposure to Humidifier Disinfectant by Lung Injury Patients (가습기 살균제 폐 손상 피해자의 살균제 노출 특성 -태아와 임산부 노출을 중심으로 -)

  • Park, Dong-Uk;Ryu, Seung-Hun;Lim, Heung-Kyu;Kim, Sun-Kyung;Ahn, Jongju;Roh, Hyun-Suk;Choi, Ye-Yong;Cha, Won-Seok;Lee, Eun;Hong, Sang-Bum;Do, Kyung-Hyun;Cho, Jae-lim;Bae, Mun-Joo;Shin, Dong-Chun;Paek, Domyung;Hong, Soo-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.3
    • /
    • pp.147-159
    • /
    • 2016
  • In South Korea, many cases of humidifier disinfectant-associated lung injury (HDLI) have been reported among people who used humidifier products containing humidifier disinfectant (HD). The objective of this study is to characterize exposure to HD among a total of 221 HDLI patients who used HD. Information and data on the HDs used were collected through a structured questionnaire and home environmental investigations. The conditions of these 221 HDLI patients were clinically confirmed to be caused by the use of HD. Children aged under 5 years old made up the highest proportion of HDLI cases (n=125, 56.6 %), followed by pregnant women (n=35, 15.8%). Forty-three percent (n=95) of the victims died. There were three cases of fetuses and 35 pregnant women among the victims. The number of HDLI patients who used only the Oxy Saksak brand of HD was found to be 85 (38.5%), followed by the HD brands Cefu (n=24, 10.9%), Lottemart Wiselect (n=9, 4.1%) and Aekyung (n=3). Patients who exclusively used HD brands containing polyhexamethylene guanidine phosphate (PHMG) (n=13, 55.7%) as an active ingredient made up the largest share, followed by those who exclusively used HD containing only oligo(2-(2-ethoxy) ethoxyethyl guanidinium (PGH) (n=24, 10.9%) and by those who only used a mixture of chloromethylisothiazolinone (CMIT) and methylisothiazolinone (MIT) (n=3, 1.4%). HD products containing PHMG were found to be the most commonly used among the confirmed HDLI patients. Three exposed fetuses who never used HD after birth developed lung injuries, indicating a probability of exposure to HD during gestation. All HDLI patients responded that they used HD while sleeping and for longer than 10 hours per day. In conclusion, the development of HDLI was clinically found to be associated with the use of several HD products containing PHMG, PGH and CMIT/MIT.

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.