• 제목/요약/키워드: HCHO (Formaldehyde)

검색결과 123건 처리시간 0.03초

보육시설, 산후조리원의 실내공기질 농도 및 위해성평가 (Concentration and risk assessment of indoor air quality in day care centers and postnatal care centers)

  • 안지희;오유진;임지영;안문섭;홍은주;손부순
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.337-345
    • /
    • 2018
  • In this study, we measured the concentration of Particulate Matter($PM_{10}$), Formaldehyde(HCHO), and Total Bacteria Count (TBC) at two facilities: day care centers, and postnatal care centers located in the cities of Gyeonggi, Gangwon, Jeolla and Gyeongsang from January 1, 2012 to December 31, 2015. $PM_{10}$ concentration was similar to the day care centers and postnatal care centers. HCHO concentration was the highest in the postnatal care centers. TBC concentration was the highest in the day care centers. Comparing the different cities, $PM_{10}$ concentration was the highest in Gyeonggi, HCHO concentration was the highest in Gyeonggi, and TBC concentration was the highest in Gyeonggi. As a result of HCHO's risk assessment, it was found that adults exceeded the carcinogenicity tolerance of $10^{-6}$ specified by the US EPA. This study is expected to be helpful in preventing damage to health from the contaminated indoor air at sensitive facilities, and can be used as basic data for indoor air quality management.

건축용 바닥재로부터의 VOCs와 Aldehydes 방출 특성 (Characteristics for VOCs and aldehydes emission rates from architectural flooring)

  • 장성기;김미현;서수연;이우석;임준호;임정연
    • 분석과학
    • /
    • 제19권6호
    • /
    • pp.544-552
    • /
    • 2006
  • 본 논문은 소형챔버법을 이용해 바닥재 종류에 따른 방출농도특성을 알아보고자 수행되었다. 환경학적 관심사가 높은 개별 휘발성유기화합물(VOC) 및 총휘발성유기화합물(TVOC)을 측정대상물질로 선정하여 HPLC 및 GC/MSD를 이용하여 분석하였다. 바닥재에서 방출된 TVOC 및 포름알데히드(HCHO)의 평균방출농도는 각각 $0.3mg/m^2{\cdot}h$$0.2mg/m^2{\cdot}h$로 나타났으며 37개 바닥재 모두 방출기준을 만족하는 것으로 조사되었다. TVOC 방출농도는 PVC Sheet, PVC Tile, 마루 순으로 나타났으며, 반면 HCHO 방출농도는 PVC 계열보다 마루 제품에서 높게 나타나는 경향을 보였다.

키즈카페의 가구류 및 설치시설에 따른 실내공기질 비교 분석 (Kids Cafe Indoor Air Quality Analysis Based on Furniture and Installation Facilities)

  • 박영훈;김선웅;양희훈;정옥영;이상진
    • 한국가구학회지
    • /
    • 제24권1호
    • /
    • pp.70-78
    • /
    • 2013
  • Indoor air quality control has been strengthened within childcare facilities and welfare communities for the elderly and infirm. I have researched the indoor air quality of kids caf$\acute{e}$s. The quality was determined by the measurement of $CO_2$ and HCHO, and the result was used in understanding of the current status of indoor air quality control. The higher level of $CO_2$ and HCHO were found in the playground area where children use compared to the area for guardians in kids caf$\acute{e}$s. And the more people in the caf$\acute{e}$s, the more $CO_2$ and HCHO were generated. It is judged that kids furniture produce harmful substances for children. Hence, the government regulations for kids caf$\acute{e}$s should be improved by reinforcing the indoor air quality control, considering that the main customers are children not adults.

  • PDF

아파트 실내공기질 현장측정에 의한 전열교환 청정환기유니트 성능평가 (IAQ Field Survey in an Apartment Housing Equiped for Heat Recovery Ventilation System with Air Cleaning Function)

  • 이정재;이중훈;이승민
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.688-693
    • /
    • 2005
  • Nowaday the natural ventilation rate decreases because the apartment housing is being air-tight. Therefore, Indoor Air Quality (IAQ) and indoor environment grow worse. Especially, Formaldehyde (HCHO), Volatile Organic Compounds (VOCs) which is emitted from the building materials and coating material etc. occur Sick House Syndrome that cause negative impact on resident's respiratory system and body. Therefore in construction field, it will be a important issues that development of a ventilation system with high effectiveness which can exhaust the contaminant out of the building quickly. In this research we evaluated 'wall attachable duct-less Heat Recovery Ventilation (HRV) system with air cleaning function'. We executed a synthetic evaluation about indoor air environment under various operating condition installing the system in real scale apartment house that is built in Anyang city. HRV system with air cleaning function showed good performance by removing HCHO, VOCs with less ventilation energy.

주거 건물에서 복합마감재의 VOCs 및 HCHO 방출에 관한 실험적 연구 (An Experimental Study on VOCs and HCHO Emission from Composite Finishing Materials in Residential Buildings)

  • 박혜원;강동화;최동희;김선숙;여명석;김광우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.289-294
    • /
    • 2006
  • Interior finishing materials are known as main VOCs and formaldehyde emission sources in residential buildings. The interior finishing materials are usually comprised of several layers with different emission properties, which complicates the emission patterns of the finishing materials. Thus, experiments on composite finishing materials and each of layers are needed to understand the emission characteristics of interior finishing materials. Results indicate that composite finishing materials have the various emission characteristics according to compositions of the materials and kinds of contaminants. Mostly, the emission rates of composite materials are higher than that of the single layer materials. The main reason is assumed to be rapid diffusion of contaminants from the bottom layer material into the top layer material.

  • PDF

4-Amino-3-hydrazino-5-mercapto-1, 2, 4-triazole을 이용한 실내 포름알데히드 측정용 passive sampler 개발 (Development of a Passive Sampler using 4-amino-3-hydrazino-5-mercapto-1, 2, 4-triazole for Measuring Indoor Formaldehyde)

  • 김선태;임봉빈;정재호
    • 한국대기환경학회지
    • /
    • 제21권6호
    • /
    • pp.593-603
    • /
    • 2005
  • Passive sampler using 4-amino-3-hydrazino-5-mercapto-1, 2, 4-triazole (AHMT) was developed to determine formaldehyde in indoor environment. The chromatography paper cleaned by $3\%$ hydrogen peroxide solution was experimently determined as a optimum absorbtion filter for the collection of formaldehyde. The passive sampler with a broad cross-sectional area and a short diffusion length was quite good in sensitivity. The passive sampler and the active sampling method with an impinger were strongly correlated with a correlation coefficient of 0.9848. The limits of detection and quantification of the passive sampler for the measurement of formaldehyde in the indoor environment were 7.5 and 10.2 ppb, respectively. Temperature ($19\∼28^{circ}C$) and relative humidity ($30\∼90\%$) had slight influence on the sampling rate of the passive sampler. However, the increase of flow velocity on the surface of sampler resulted in the increase of sampling rate.

SnO2-ZnO를 이용한 가스 센서의 포름알데히드 가스 감지특성 (Formaldehyde Gas-Sensing Characteristics of SnO2-ZnO Materials)

  • 윤진호;이회중;김정식
    • 대한금속재료학회지
    • /
    • 제48권2호
    • /
    • pp.169-174
    • /
    • 2010
  • A micro gas sensor for formaldehyde (HCHO) gas was fabricated by using MEMS (Micro Electro Mechanical System) technology and the sol-gel process. The sensing materials of the $SnO_2$-ZnO system were synthesized by the sol-gel method. The crystal structure and thermal analysis of the $SnO_{2}$-ZnO were characterized by XRD and DSC-TGA. The fabricated gas sensors were tested at various gas concentrations (0.5~5.0 ppm) and different operation temperatures ($350{\sim}550^{\circ}C$). The $SnO_2$-10 mol%ZnO sensor showed the highest sensitivity ($R_s=0.24$) for 1.0 ppm-formaldehyde at $500^{\circ}C$ and response time (90% saturation time) was within 20 seconds.

Bake Out에 의한 실내오염물질 저감에 관한 연구 (A Study on the Reducing Ratio of VOCs and Formaldehyde by Bake Out)

  • 조현;박용승;유복희;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2004년도 추계학술대회 논문집
    • /
    • pp.319-322
    • /
    • 2004
  • The purpose of this study is to evaluate the reduction effect of bake out on the concentration of indoor air pollutants by measuring the concentration of indoor pollutants(VOCs, HCHO) after the bake out. As a result of the study, bake out was considerably effective in reducing the concentration o( indoor air pollutants, showing relatively high reduction ratio around 40${\sim}$56%. However, continuous attention and control after the bake out is required for the prevention of the rise of the concentration by subsequent emission.

  • PDF

목질 섬유판 제조에 있어 도계부산물인 닭털의 목섬유 부분적 대체화 탐색 (Investigating the Partial Substitution of Chicken Feather for Wood Fiber in the Production of Wood-based Fiberboard)

  • 양인;박대학;최원실;오세창;안동욱;한규성;오승원
    • Korean Chemical Engineering Research
    • /
    • 제56권4호
    • /
    • pp.577-584
    • /
    • 2018
  • 본 연구는 목질계 섬유판 제조에 있어 목섬유에 대한 도계부산물인 닭털의 부분적 대체화 가능성을 검토하기 위하여 수행하였다. 닭털은 주로 케라틴계 단백질로 구성되어 있으며, 외형적으로 목섬유와 큰 차이는 없었다. 닭털의 전처리 방법에 따른 포름알데히드 흡착능을 비교한 결과, 닭털을 고온/고압에서 처리하고 분쇄한 우모분에서 가장 높았다. 한편 일반 가위로 절단한 닭털과 이를 가정용 믹서로 고해시킨 닭털의 폼알데히드 흡착량을 dinitrophenylhydrazine법으로 측정한 결과 차이는 없었다. 닭털, 고해 닭털, 우모분을 각각 목섬유의 전건무게를 기준으로 5 wt%로 혼합하여 제조한 중밀도섬유판(MDF)의 물성과 폼알데히드방출량은 닭털의 전처리 조건에 영향을 받지 않았다. 그러나 이 측정치를 목섬유만으로 제조한 MDF와 비교하였을 때, 두께팽윤율과 폼알데히드방출량은 크게 개선되었다. 따라서 현재 생산 현장에서 적용되고 있는 요소수지를 이용한 MDF 제조에 있어 목섬유와 함께 일정한 양의 닭털, 고해 닭털 또는 우모분을 첨가할 경우 치수안전성과 폼알데히드방출량이 개선된 MDF의 제조가 가능할 것으로 예상된다. 그러나 MDF제조에 있어 닭털의 사용은 현재 상황에서 목섬유와 비교하여 원료 확보의 어려움과 높은 단가로 경제성이 낮은 것으로 조사되었다. 경제성 향상을 위하여 중소형 도계장에서 발생하는 닭털을 이용하거나, 동물성 사료의 금지에 대한 대비책 및 인플루엔자 감염 조류에 대한 환경적 처리 방안으로 닭털의 섬유판 원료에 대한 부분적 대체화 기술은 향후 사용 가능성이 충분할 것으로 판단된다.

포름알데히드 상온산화 촉매의 상용화를 위한 촉매 제조 및 공정 운전조건 최적화 연구 (A Study on the Optimization of Process Operation & Catalyst Preparing for Commercialization of Formaldehyde Room Temperature Oxidation Catalyst)

  • 이상현;박인출;김성수
    • 한국지반환경공학회 논문집
    • /
    • 제17권10호
    • /
    • pp.5-11
    • /
    • 2016
  • 본 연구에서는 포름알데히드를 상온산화시켜 제거하는 $Pt/TiO_2$ 촉매의 상용화 인자들이 조사되었다. 활성 귀금속 함량 최적화를 위해 촉매의 백금(Pt) 담지량을 변화시켜 제조 후 성능을 평가하였으며, 그 결과 1wt% 함량이 가장 이상적인 함량임을 확인하였다. 또한 활성금속인 Pt를 환원하여 제조한 환원 촉매가 상온에서 우수한 포름알데히드 산화 능력을 나타내었다. 이를 통해 활성금속의 산화가에 따라 성능이 변화될 수 있으며, 백금의 경우 metallic Pt($Pt^0$)로 존재할수록 포름알데히드 상온산화 성능이 증진될 수 있음을 확인하였다. 촉매의 운전인자를 도출하기 위한 공간속도 영향 평가 결과 공간속도가 낮을수록 촉매량 증가에 의해 포름알데히드 전환율이 증진되는 결과를 나타내었다. 또한 공기 내 반드시 존재하는 물질인 수분의 공기 내 공존 시 영향 평가를 실시하였으며, 그 결과 수분이 공존할 때 포름알데히드 산화반응이 수분이 존재하지 않은 조건에서의 활성보다 증진되었다. 상기 결과들을 통해 어떤 추가 에너지원 없이도 포름알데히드를 제거 할 수 있는 상온산화 촉매 상용화를 위한 핵심인자들을 확인하였다.