Browse > Article
http://dx.doi.org/10.5806/AST.2006.19.6.544

Characteristics for VOCs and aldehydes emission rates from architectural flooring  

Jang, Seong-Ki (Indoor Air Quality Division, National Institute of Environmental Research)
Kim, Mi-Hyun (Indoor Air Quality Division, National Institute of Environmental Research)
Seo, Soo-Yun (Indoor Air Quality Division, National Institute of Environmental Research)
Lee, Woo-Suk (Indoor Air Quality Division, National Institute of Environmental Research)
Lim, Jun-Ho (Indoor Air Quality Division, National Institute of Environmental Research)
Lim, Jeong-Yun (Indoor Air Quality Division, National Institute of Environmental Research)
Publication Information
Analytical Science and Technology / v.19, no.6, 2006 , pp. 544-552 More about this Journal
Abstract
Emission tests were carried out to investigate the characteristics of concentration according to flooring sort using small chamber method. The target Volatile Organic Compounds (VOC) included 27 individual compounds of environmental concern, which were determined by adsorption sampling and thermal desorption coupled with GC/MS method and by DNPH cartridge/HPLC method. The emission factor of Total Volatile Organic Compounds (TVOC) and Formaldehyde (HCHO) was detected $0.3mg/m^2{\cdot}h$ and $0.2mg/m^2{\cdot}h$ respectively, and the floorings of 37 (9 PVC Tile, 10 PVC Sheet, 18 Flooring) were satisfied emission standard. TVOC emission factor appeared in order of concentration of PVC Sheet, PVC Tile, and floor flooring, while HCHO was detected very high emission factor (as $0.4mg/m^2{\cdot}h$) at floor flooring above PVC series (as $0.001mg/m^2{\cdot}h$).
Keywords
small chamber method; TVOC; HCHO; toluene; PVC sheet flooring; floor flooring;
Citations & Related Records
연도 인용수 순위
  • Reference
1 환경부, 실내공기질관리법 제정에 대한 공청회 자료 집, 1995
2 ECA, 'European Comission , Guideline for the characterization of volatile organic compounds emitted from indoor materials and products using small test chambers', Report No. 8, 1991
3 WHO, Air quality guidelines for Europe, WHO Pub. European Series No. 23(1987)
4 V.J. Feron, H.P. Til, Flora de Vrijer, and P.J. Bladeren, Indoor Environ., 1, 69-81(1992)   DOI
5 D.R. Patrick, 'Toxic Air Pollution Handbook', Van Nostrand Reinhol, New York, 1994
6 환경부, '실내공기질공정시험방법', 환경부 고시 제 2004-80호, 160-175, 2004
7 A. Hedge, Indoor Environ., 4, 251-253(1995)   DOI
8 R.S. Maria, Indoor Air, 9, 268-272(1999)   DOI   ScienceOn
9 D.W. Dockery and J.P. Spengler, Air Pollut. Control Assoc., 31, 153-159(1981)   DOI   ScienceOn
10 이석조, 장성기, 김미현, 이홍석, 임준호, 장미, 서수 연, 한국분석과학회지, 18(4), 344-354(2005)
11 J.M. Samet and J.D. Spengler, Indoor Air Pollution, Johns Hopkins University Press, London, 1991
12 C.C. Chan, H. Ozkaynak, J.D. Spengler, J.D., and L. Sheldon, Environ. Sci. Technol., 25, 964-972(1991)   DOI
13 ASTM D 5116-97, 'Standard guide for small-scale environmental chamber determinations of organic emissions from indoor materials/products', 1997
14 장성기, 이우석, 김상돈, 서수연, 이홍석, 임준호, 임 정연, '건축자재 오염물질 방출시험 방법 최적화 및 방출특성연구', 1-79, 국립환경과학원, 2005
15 A.T. Hodgson, D. Beal and J.E.R. Mecllvaine, Indoor Air, 12, 235-242(2002)   DOI   ScienceOn