• Title/Summary/Keyword: H-Bridge Inverter

Search Result 279, Processing Time 0.028 seconds

A New Basic Unit for Cascaded Multilevel Inverters with the Capability of Reducing the Number of Switches

  • Laali, Sara;Babaei, Ebrahim;Sharifian, Mohammad Bagher Bannae
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.671-677
    • /
    • 2014
  • In this paper, a new basic unit is proposed. Then, a cascaded multilevel inverter basded on the series connection of n number of these new basic units is proposed. In order to generate all of the voltage levels (even and odd) at the output, three different algorithms to determine the magnitude of the dc voltage source are proposed. Reductions in the number of power switches, driver circuits and dc voltage sources in addition to increases in the numbr of output voltage levels are some of the advantages of the proposed cascaded multilevel inverter. These results are obtained through a comparison of the proposed inverter and its algorithms with an H-bridge cascaded multilevel inverter from the point of view of the number of power electronic devices. Finally, the capability of the proposed topology with its proposed algorithms in generating all of the voltage levels is verified through experimental results on a laboratorary prototype of a 49-level inverter.

Single Phase 5-level Inverter with DC-link Switches (DC링크 스위치를 갖는 단상 5레벨 인버터)

  • Choi, Young-Tae;Sun, Ho-Dong;Park, Min-Young;Kim, Heung-Geun;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.283-292
    • /
    • 2011
  • This paper proposed a new multi-level inverter topology based on a H-bridge with two switches and two diodes connected to the DC-link. The output voltage of the proposed topology is quite closer to a sinusoidal waveform compared with a typical single phase inverter. The proposed multi-level inverter is applicable to a power conditioning system for renewable energy sources, and it can be also used as a building block of a cascaded multi-level inverter for a high voltage application. In case of conventional H-bridge type or NPC type multi-level inverter, 8 controllable switches are used to obtain a 5 level output voltage, but the proposed multi-level inverter requires only 6 controllable switches. Thus the circuit configuration is quite simple, reliable and cost-effective implementation is possible. The efficiency can be improved owing to the reduction of the switching loss. A new PWM method based on POD modulation is suggested which requires only one carrier signal. The switching sequence to make the capacitor voltage balanced is also considered. The feasibility is studied through simulation and experiment.

A Fault Diagnosis Method in Cascaded H-bridge Multilevel Inverter Using Output Current Analysis

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2278-2288
    • /
    • 2017
  • Multilevel converter topologies are widely used in many applications. The cascaded H-bridge multilevel inverter (CHBMI), which is one of many multilevel converter topologies, has been introduced as a useful topology in high and medium power. However, it has a drawback to require a lot of switches. Therefore, the reliability of CHBMI is important factor for analyzing the performance. This paper presents a simple switch fault diagnosis method for single-phase CHBMI. There are two types of switch faults: open-fault and short-fault. In the open-fault, the body diode of faulty switch provides a freewheeling current path. However, when the short-fault occurs, the distortion of output current is different from that of the open-fault because it has an unavailable freewheeling current flow path due to a disconnection of fuse. The fault diagnosis method is based on the zero current time analysis according to zero-voltage switching states. Using the proposed method, it is possible to detect the location of faulty switch accurately. The PSIM simulation and experimental results show the effectiveness of proposed switch fault diagnosis method.

A Flyback-Assisted Single-Sourced Photovoltaic Power Conditioning System Using an Asymmetric Cascaded Multilevel Inverter

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2272-2283
    • /
    • 2016
  • This paper proposes a power conditioning system (PCS) for distributed photovoltaic (PV) applications using an asymmetric cascaded multilevel inverter with a single PV source. One of the main disadvantages of the cascaded multilevel inverters in PV systems is the requirement of multiple isolated DC sources. Using multiple PV strings leads to a compromise in either the voltage balance of individual H-bridge cells or the maximum power point tracking (MPPT) operation due to localized variations in atmospheric conditions. The proposed PCS uses a single PV source with a flyback DC-DC converter to facilitate a reduction of the required DC sources and to maintain the voltage balance during MPPT operation. The flyback converter is used to provide input for low-voltage H-bridge cells which processes only 20% of the total power. This helps to minimize the losses occurring in the proposed PCS. Furthermore, transient analyses and controller design for the proposed PCS in both the stand-alone mode and the grid-connection mode are presented. The feasibility of the proposed PCS and its control scheme have been tested using a 1kW hardware prototype and the obtained results are presented.

Switching pattern for decreasing switching loss in cascaded H-bridge multilevel PWM inverter controlled by sinusoidal pulse width modulation with multi-carrier waves (다중 반송파 정현 펄스폭 변조방식으로 제어되는 Cascaded H-bridge 멀티레벨 PWM 인버터의 스위칭 손실 저감을 위한 스위칭 패턴)

  • Choi, Jin-sung;Kim, Ki-du;Jung, Bo-chang;Kang, Feel-soon
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.61-62
    • /
    • 2012
  • 본 논문에서는 다중 반송파 정현 펄스폭 변조방식으로 제어되는 Cascaded H-bridge 멀티레벨 PWM 인버터의 스위칭 손실 저감을 위한 스위칭 패턴을 제안한다. 부하 담당 전력이 상대적으로 큰 H-bridge 모듈의 스위치는 저주파의 기본 출력 전압 레벨을 형성하도록 동작시키며, 부하 담당 전력이 상대적으로 작은 H-bridge 모듈의 스위치는 고주파의 PWM 파형을 기본파에 가감하여 출력전압 파형이 사인파에 가까워지도록 스위칭 패턴을 형성한다. 본 논문에서는 제안된 스위칭 패턴을 PD, APOD 방식의 다중 반송파 정현 펄스폭 변조방식으로 구현하여 Cascaded H-bridge 멀티레벨 PWM 인버터에 적용시키고 실험을 통해 기존의 스위칭 패턴에 비해 스위칭 손실이 개선됨을 증명한다.

  • PDF

Single input source driving of cascaded H-bridge multilevel inverter by using forward converter (포워드 컨버터를 응용한 Cascaded H-Bridge 멀티레벨 인버터의 단일 입력전원 구동)

  • Kim, Sun-Pil;Kang, Feel-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1161-1162
    • /
    • 2011
  • 본 논문에서는 독립된 DC 입력전원을 요구하는 Cascaded H-bridge 멀티레벨 인버터를 단일 입력전원으로 구동시키기 위한 회로 구조를 제안한다. 변압기 포화를 방지하기 위해 채용되는 리센 권선을 가지는 포워드 컨버터의 구조를 변경한 것으로 리셋 권선에 의해 전원으로 회생되는 에너지가 출력단으로 전달되도록 변경된다. 제안된 회로 구조의 입출력전압과 스위치의 도통비와의 관계를 이론적으로 분석하고 시뮬레이션을 통해 타당성을 검증한다.

  • PDF

Novel Level-Shift PWM for Power and Loss Distribution of Cascaded NPC/H-bridge Multi Level Inverter (Cascaded NPC/H-bridge 멀티 레벨 인버터의 전력 및 손실 분배를 위한 새로운 Level-Shift PWM 기법)

  • Ha, Jae-Ok;Kang, Jin-Wook;Hyun, Seung-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.270-271
    • /
    • 2017
  • Cascaded NPC/H-bridge 인버터의 기존 Level-Shift PWM에서는 한 stack에서 전력 및 손실 불균형이 발생하게 된다. 이에 따라 손실 불균형을 개선하기 위해 새로운 Level Shift PWM을 개발하였고, PSIM 9.14를 통해 기존의 PWM 기법들과 비교 분석 하였다.

  • PDF

A Study on the Development of Induction Heating System for Using Full-Bridge High-Frequency Resonant Inverter (Full-Bridge 고주파 공진형 인버터를 이용한 유도가열시스템의 개발에 관한 연구)

  • Kwon H.M.;Kim S.H.;Shln D.C,;Kim Y.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.19-22
    • /
    • 2003
  • In this paper are described the indirect induction heated boiler and induction heated hot air producer using the voltage-fed series resonant high-frequency inverter which can operate in the frequency range from 20 [kHz] to 50 [kHz]. A specially designed induction heater, which is composed of laminated stainless assembly with many tiny holes and interconnected spot welding points between stainless plates, is inserted into the ceramic type vessel with external working coil. This working coil is connected to the inverter and turbulence fluid through this induction heater to moving fluid generates in the vessel. The operating performances of this unique appliance in next generation and its effectiveness are evaluated and discussed from a practical point of view.

  • PDF

Design and Verification of Improved Cascaded Multilevel Inverter Topology with Asymmetric DC Sources

  • Tarmizi, Tarmizi;Taib, Soib;Desa, M.K. Mat
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1074-1086
    • /
    • 2019
  • This paper presents the design and implementation of an improved cascaded multilevel inverter topology with asymmetric DC sources. This experimental inverter topology is a stand-alone system with simulations and experiments performed using resistance loads. The topology uses four asymmetric binary DC sources that are independent from each other and one H-bridge. The topology was simulated using PSIM software before an actual prototype circuit was tested. The proposed topology was shown to be very efficient. It was able to generate a smooth output waveform up to 31 levels with only eight switches. The obtained simulation and experimental results are almost identical. In a 1,200W ($48.3{\Omega}$) resistive load application, the THDv and efficiency of the topology were found to be 1.7% and 97%, respectively. In inductive load applications, the THDv values were 1.1% and 1.3% for an inductive load ($R=54{\Omega}$ dan L=146mH) and a 36W fluorescent lamp load with a capacitor connected at the dc bus.

Multilevel Inverter using Two 5-level Inverters Connected in Series (두 대의 5-레벨 인버터의 직렬결합을 이용한 멀티레벨인버터)

  • Choi, Won-Kyun;Kwon, Cheol-Soon;Hong, Un-Taek;Kang, Feel-Soon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.376-380
    • /
    • 2010
  • This paper presents a circuit configuration of multilevel inverter to increase the number of output voltage levels by using conventional 5-level inverters connected in series. Most of all it can maximize the number of output voltage levels by employing input voltage sources, which have the power of five. When it synthesizes the same number of output voltage levels, the proposed inverter can save the number of switching devices compared with the conventional cascaded H-bridge cell inverter. So it can reduce the size, cost, power consumption of the system. We implemented computer-aided simulation and experiments for a 25-level inverter employing two 5-level inverters.