• Title/Summary/Keyword: Gutta-percha cone

Search Result 55, Processing Time 0.028 seconds

Influence of CBCT metal artifact reduction on vertical radicular fracture detection

  • Oliveira, Mariana Rodrigues;Sousa, Thiago Oliveira;Caetano, Aline Ferreira;de Paiva, Rogerio Ribeiro;Valladares-Neto, Jose;Yamamoto-Silva, Fernanda Paula;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • Purpose: This study evaluated the influence of a metal artifact reduction (MAR) tool in a cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures (VRFs) in teeth with different root filling materials. Materials and Methods: Forty-five extracted human premolars were classified into three subgroups; 1) no filling; 2) gutta-percha; and 3) metallic post. CBCT images were acquired using an Orthopantomograph 300 unit with and without a MAR tool. Subsequently, the same teeth were fractured, and new CBCT scans were obtained with and without MAR. Two oral radiologists evaluated the images regarding the presence or absence of VRF. Receiver operating characteristic (ROC) curves and diagnostic tests were performed. Results: The overall area under the curve values were 0.695 for CBCT with MAR and 0.789 for CBCT without MAR. The MAR tool negatively influenced the overall diagnosis of VRFs in all tested subgroups, with lower accuracy (0.45-0.72), sensitivity (0.6-0.67), and specificity (0.23-0.8) than were found for the images without MAR. In the latter group, the accuracy, sensitivity, and specificity values were 0.68-0.77, 0.67-083, and 0.53-087, respectively. However, no significant difference was found between images with and without MAR for the no filling and gutta-percha subgroups (P>0.05). In the metallic post subgroup, CBCT showed a significant difference according to MAR use (P<0.05). Conclusion: The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.

Assessment of decontamination of gutta-percha cone and the change of surface texture after rapid chemical disinfection (화학소독제 처리 후 가타파차 콘의 멸균 효과 및 표면 성상의 변화 평가)

  • Pang, Nan-Sim;Jung, Il-Young;Yu, Yoon-Jung;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.133-139
    • /
    • 2006
  • The purposes of this study were firstly to identify the microbial species on gutta-percha (GP) cones exposed at outpatient clinics using polymerase chain reaction, and secondly to evaluate the rapid sterilization effect of two chemical disinfectants at chair side. It also evaluated the alteration of surface texture of GP cones after 5-min soaking into two chemical disinfectants. A total of 100 GP cones from two endodontic departments were randomly selected for microbial detection using PCR assay with universal primer. After inoculation on the sterilized GP cones with the same microorganism identified by PCR assay, they were soaked in two chemical disinfectants: 5% NaOCl and 2% chlorhexidine for 1, 3, 5, and 10 minutes. The sterilization effect was evaluated by turbidity and subculture. The change of surface textures using a scanning electron microscope was also examined after 5 min-soaking in two chemical disinfectants. Results showed that four bacterial species were detected in 17 GP cones, and all the species belonged to the genus Staphylococcus. Two chemical disinfectants were effective in sterilization with just 1 minute soaking. On the SEM picture of NaOCl-soaked GP cone, a cluster of cuboidal crystals was seen on the cone surface. Present data demonstrate that two chemical disinfectants are useful for rapid sterilization of GP cone just before obturation at chair side, while CHX-soaked GP cone has cleaner surface without crystal precipitation than that of NaOCl-treated cone.

Bacterial leakage and micro-computed tomography evaluation in round-shaped canals obturated with bioceramic cone and sealer using matched single cone technique

  • Yanpiset, Kallaya;Banomyong, Danuchit;Chotvorrarak, Kanet;Srisatjaluk, Ratchapin Laovanitch
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.3
    • /
    • pp.30.1-30.12
    • /
    • 2018
  • Objectives: To evaluate sealing ability of root canals obturated with bioceramic-impregnated gutta percha cone (BCC) or gutta percha (GP), with bioceramic sealer (BCS) or AH Plus (AH; Dentsply-Maillefer), in roundly-prepared canals using matched single-cone technique, based on bacterial leakage test, and to analyze obturation quality using micro-computed tomography (CT) analysis. Materials and Methods: Ninety-two distobuccal roots of maxillary molars were prepared using nickel-titanium files to apical size 40/0.06. The roots were divided into 4 groups (n = 20) that were obturated with a master cone and sealer: GP/AH, BCC/AH, GP/BCS, and BCC/BCS. Bacterial leakage model using Enterococcus faecalis was used to evaluate sealing ability for 60-day period. Obturated samples from each group (n = 4) were analyzed using micro-CT. Results: All groups showed bacterial leakage at 20%-45% of samples with mean leakage times of 42-52 days. There were no significant differences in bacterial leakage among the groups. Micro-CT showed minimal gaps and voids in all groups at less than 1%. Conclusions: In roundly-prepared canals, the single cone obturation with BCC/BCS was comparable to GP/AH for bacterial leakage at 60 days.

MICROLEAKAGE OF THE CLASS V CAVITY ACCORDING TO RESTORATION SITE AND CAVITY SIZE USING SEM AND THREE-DIMENSIONAL RECONSTRUCTION TECHNIQUES (SEM과 3차원 재구성법을 이용한 수복면의 위치와 와동 크기에 따른 미세누출도 분석)

  • Yang, In-Seo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.112-120
    • /
    • 2005
  • This study was done to evaluate whether there were any differences in microleakage of class V composite restorations according to restoration site and cavity size. Total sixty-four restorations were made in molar teeth using Esthet-X. Small ($2\;{\times}\;2\;{\times}\;1.5\;mm$) and large ($4{\times}2{\times}1.5\;mm$) restorations were made at the buccal/lingual surface and the proximal surface each. After 1,000 times of thermocycling ($5^{\circ}\;-\;55^{\circ}C$), resin replica was made and the percentage of marginal gap to the whole periphery of the restoration was estimated from SEM evaluation. Thermocycled tooth was dye penetrated with $50\%$ silver nitrate solution. After imbedding in an auto-curing resin, it was serially ground with a thickness of 0.25 mm. Volumetric microleakage was estimated after reconstructing three dimensionally. Two-way ANOVA and independent T-test for dye volume, Mann-Whitney U test for the percentage of marginal gap, Spearman's rho test for the relationship between two techniques were used, The results were as follows : 1. The site and size of the restoration affected on the microleakage of restoration. Namely, much more leakage was seen in the proximal and the large restorations rather than the buccal/lingual and the small restorations. 2. Close relationship was found between two techniques (Correlation coefficient = 0.614/ P = 0.000). Within the limits of this study, it was noted that proximal and the large restorations leaked more than buccal/lingual and the small restorations. Therefore, it should be strictly recommended large exposure of margins should be avoided by reducing unnecessary tooth reduction.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

EVALUATION OF THE APICAL SEAL PRODUCED BY THE SINGLE CONE FILLING AND BY THE LATERAL CONDENSATION (근관충전방법이 근관폐쇄성에 미치는 영향에 관한 실험적 연구)

  • Park, Joon-II;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.9 no.1
    • /
    • pp.51-57
    • /
    • 1983
  • 64 multi-rooted teeth (198 canals) were tested in vitro to evaluate the apical seal produced by the single cone filling and lateral condensation with sealer and without sealer. The obturated teeth were immersed in India ink, decalcified, and cleared. The degree of ink penetrated into the canal provided a measure of the apical seal. The results were as follows: 1. The lateral condensation with sealer provided statically less apical leakage than the other obturating techniques used in this study. 2. The single cone filling provided good apical sealing. 3. The lateral condensation without sealer provided most apical leakage than any other techniques used in this study. 4. The degree of apical leakage was not related to the visual appearence of the adaptation of the gutta percha filling in cleared teeth.

  • PDF

An assessment of maxillary sinus and alveolar bone in cross-sectional linear tomogram of panorama (파노라마촬영장치의 협설선형단층상에 의한 상악동과 치조골 평가)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.137-141
    • /
    • 2003
  • Purpose: To evaluate the precision of measurements taken of dental implants in bucco-lingually sectioned views of the maxilla by linear tomograms of the panorama and to assess the visibility of the inferior wall of the maxillary sinus. Materials and Methods : Eighty sites prepared with implants of gutta percha cone in the sockets of the upper premolars and molars of 10 dry skulls were radiographically examined using linear tomograms of panorama, and scanned coronally and axially by computed tomography. The differences in mm between the measurements in bucco-lingually sectioned images of maxillary alveolar bone and the true length and width of the implanted gutta percha cones were compared as mean values (mean) and standard deviations (SD) for each radiographic technique. Linear tomography of panorama was compared with computed tomography for visualization of the relationship between the inferior wall of maxillary sinus and the end of each implant. Results: The deviations between the actual implant length and the measured values taken from the linear tomograms (0.44±0.39 mm) was significantly less than the measured values from the multiplanar reconstructed images of the axially scanned computed tomogram (1.21 ± 0.90 mm). There was statistically significant difference (p < 0.05) between two techniques in the differences between the measurements and true implant length. The relationship of the inferior border of maxillary sinus with end of implant was worse identified with the linear tomogram of panorama (68%) than the multiplanar reconstructed image of axially scanned computed tomogram (99%). Conclusion: We could not find any differences in the accuracy of length measurement between the linear tomogram of panorama and computed tomogram, but computed tomogram allowed for a better visualization of the inferior wall of the maxillary sinus than the linear tomogram.

  • PDF

Use of cone-beam computed tomography and three-dimensional modeling for assessment of anomalous pulp canal configuration: a case report

  • Sinanoglu, Alper;Helvacioglu-Yigit, Dilek;Mutlu, Ibrahim
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.161-165
    • /
    • 2015
  • Three-dimensional (3D) reconstruction of cone-beam computed tomography (CBCT) scans appears to be a valuable method for assessing pulp canal configuration. The aim of this report is to describe endodontic treatment of a mandibular second premolar with aberrant pulp canal morphology detected by CBCT and confirmed by 3D modeling. An accessory canal was suspected during endodontic treatment of the mandibular left second premolar in a 21 year old woman with a chief complaint of pulsating pain. Axial cross-sectional CBCT scans revealed that the pulp canal divided into mesiobuccal, lingual, and buccal canals in the middle third and ended as four separate foramina. 3D modeling confirmed the anomalous configuration of the fused root with a deep lingual groove. Endodontic treatment of the tooth was completed in two appointments. The root canals were obturated using lateral compaction of gutta-percha and root canal sealer. The tooth remained asymptomatic and did not develop periapical pathology until 12 months postoperatively. CBCT and 3D modeling enable preoperative evaluation of aberrant root canal systems and facilitate endodontic treatment.

CLINICAL STUDY ON THE EFFECT OF VITAPEX UPON THE PERIAPICAL TISSUE (Vitapex가 치근단 조직에 미치는 영향에 관한 임상적 연구)

  • Kim, Min-Kyum;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.463-468
    • /
    • 1993
  • The purpose of this study was to evaluate the effects of Vitapex on the periapical lesions. Thirteen single-rooted teeth from ten patients who visited the SNU hospital were endodontically treated with Vitapex and Gutta percha cone, and radiographically and clinically evaluated for a period of 1 to 6 months. The results were as follows : 1. The loss of clinical symtoms was observed in all 13 teeth. 2. The reduction of size of periapical lesions in radiographs was observed in 10 teeth. The periapical lesions of remaining 3 teeth also look better in the radiographs. 3. All 13 teeth showed the reduction of radiolucency. 4. The gradual resorption of Vitapex over the root apex was observed.

  • PDF