A Study on Performance Characteristics Wide Angle Diffuser Using Guide Damper (안내댐퍼를 이용한 광각디퓨저의 성능특성에 관한 연구)

  • Lee, Cheol-Jae;Lim, Jeong-Sun;Cho, Dae-Hwan
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.281-282
    • /
    • 2006
  • In wide angle diffuser, the increasement of cross-sectional area so rapidly cause possibly separate from the diffuser wall and forming areas of backflow. The flow characteristics of wide angle diffuser with guide damper was investigated for three kind of inclined angle($\alpha=7_{\circ},\;10.5_{\circ}\;and\;14_{\circ}$)of guide damper. Judging from the results, guide damper can be used as an effective means of improvement for diffuser performance and inclined angle of $\alpha=10.5^{\circ}$ was through to be the best among three cases.

  • PDF

Hysteretic Behavior of Steel Damper using Guide Plate and Channel (가이드 판과 채널을 사용한 강재 댐퍼의 이력 거동)

  • Lee, Hyun-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2021
  • In this study, a rocking behavior experiment using a guide plate and a guide channel to prevent lateral deformation of a steel damper was planned. For this purpose, strut I-type specimen I-1 and strut S-type specimen S-1 were prepared. The experimental results were compared with the existing experimental results of SI-260 and SS-260 under the same conditions without the details of lateral deformation prevention in order to evaluate the effect of preventing lateral deformation. The damper with lateral deformation prevention detail was evaluated to have superior strength capacity, deformation capacity, and energy dissipation capacity than the damper without it. Therefore, the lateral deformation prevention detail was evaluated to have a good effect in improving the design capability of the steel damper.

Experimental and Numerical Study on Performance Analysis of a Planar Diffuser (평판형 디퓨져의 성능해석에 관한 실험 및 수치해석)

  • 조대환;이철재;배석태;김성동
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.63-68
    • /
    • 2001
  • In wide angle diffuser, the cross-sectional area increases so rapidly that separation can be avoided only by using boundary layer control. In this study, an experimental and numerical study is performed on performance of a diffuser with guide damper. A series of measurements were carried out to investigate the characteristics of diffuser for different divergence angle(${\phi}=7^{\circ}, \;10.5^{\circ}\;and\; 14^{\circ}$) of guide damper and angle of ${\phi}=10.5^{\circ}$ was through to be the best among three cases. Judging from the results, guide damper can be used as an effective means of improvement for diffuser performance.

  • PDF

Cable vibration control with internal and external dampers: Theoretical analysis and field test validation

  • Di, Fangdian;Sun, Limin;Chen, Lin
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.575-589
    • /
    • 2020
  • For vibration control of stay cables in cable-stayed bridges, viscous dampers are frequently used, and they are regularly installed between the cable and the bridge deck. In practice, neoprene rubber bushings (or of other types) are also widely installed inside the cable guide pipe, mainly for reducing the bending stresses of the cable near its anchorages. Therefore, it is important to understand the effect of the bushings on the performance of the external damper. Besides, for long cables, external dampers installed at a single position near a cable end can no longer provide enough damping due to the sag effect and the limited installation distance. It is thus of interest to improve cable damping by additionally installing dampers inside the guide pipe. This paper hence studies the combined effects of an external damper and an internal damper (which can also model the bushings) on a stay cable. The internal damper is assumed to be a High Damping Rubber (HDR) damper, and the external damper is considered to be a viscous damper with intrinsic stiffness, and the cable sag is also considered. Both the cases when the two dampers are installed close to one cable end and respectively close to the two cable ends are studied. Asymptotic design formulas are derived for both cases considering that the dampers are close to the cable ends. It is shown that when the two dampers are placed close to different cable ends, their combined damping effects are approximately the sum of their separate contributions, regardless of small cable sag and damper intrinsic stiffness. When the two dampers are installed close to the same end, maximum damping that can be achieved by the external damper is generally degraded, regardless of properties of the HDR damper. Field tests on an existing cable-stayed bridge have further validated the influence of the internal damper on the performance of the external damper. The results suggest that the HDR is optimally placed in the guide pipe of the cable-pylon anchorage when installing viscous dampers at one position is insufficient. When an HDR damper or the bushing has to be installed near the external damper, their combined damping effects need to be evaluated using the presented methods.

Useful Guide to Solve Herschel-Bulkley Model in a Flow Mode Damper (유동 모드 댐퍼에서의 Herschel-Bulkley 모델의 유용한 해법)

  • 이덕영;박성태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.784-787
    • /
    • 2003
  • Electrorheological(ER) and magnetorheological(MR) fluid-based dampers are typically analyzed using Bingham-plastic shear model under quasi-steady fully developed flow conditions. A Herschel-Bulkley constitutive shear flow relationship is that the linear shear stress vs. strain rate behavior of Bingham model is replaced by a shear stress that is assumed to be proportional to a power law of shear rate. This power is called the flow behavior index. Depending on the value of the flow behavior index number, varying degrees of post-yield shear thickening or thinning behavior can be analyzed. But it is not practical to analyze the damping force in a flow mode damper using Herschel-Bulkley model because it is needed to solve a polynomial equation. A useful guide is suggested to analyze the damping force in a damper using the Herschel-Bulkley model.

  • PDF

Performance Test of a Tuned Liquid Mass Damper installed in a Real-Scaled Structure (실물크기 구조물에 설치된 동조액체질량감쇠기의 성능실험)

  • Heo, Jae-Sung;Park, Eun-Churn;Lee, Sung-Kyung;Lee, Sang-Hyun;Kim, Hong-Jin;Jo, Ji-Seong;Cho, Bong-Ho;Joo, Seok-Jun;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.2
    • /
    • pp.161-168
    • /
    • 2008
  • In this paper, a tuned liquid mass damper(TLMD) was proposed and experimentally investigated on its control performance, which can control bi-axial responses of building structures by using only one device. The proposed TLMD controls the structural response in a specific one direction by using a liquid sloshing of TLCD. Also, the TLMD reduces the response of structures in the other orthogonal direction by behaving as a TMD that uses mass of the container itself and liquid within container of TLCD installed on linear motion guides. Force-vibration tests on a real-sized structure installed with the TLMD were performed to verify its independent behavior in two orthogonal directions. Test results showed that the responses of a structure were considerably reduced by using the proposed TLMD and its usefulness for structural control in two orthogonal directions.

Influence on the Torsional Vibration of Input Shaft and the Vibration of Vehicle by Damper Clutch in Auto-Transmission (자동변속기의 댐퍼 클러치가 Input Shaft 의 비틀림 진동 및 차체 진동에 미치는 영향 연구)

  • Jung, Byung-Hwan;Hwang, Seon-Yang;Kang, Koo-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.344-350
    • /
    • 2009
  • According to torsional vibration characteristic of a damper clutch in auto-transmission, the input shaft system have occurred breakdown for the duration cycle and over-vibration happened on vehicle at specific condition. This paper describes the improvement of the torsional vibration of input shaft and the vehicle vibration by tuning of the damper clutch and suggests to the guide line about torsion characteristic on the design of damper clutch.

  • PDF

Analysis of Structure and Endurance for Cylinder-type Door Closer (실린더타입 도어클로저의 구조 및 내구해석)

  • 김민건;정구현;박찬원
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.3
    • /
    • pp.91-97
    • /
    • 2004
  • The door closer is a typical system which consists of spring and damper. The door closer is a device to close the door more slowly. The virtual prototypes of cylinder-type door closer are developed. The simulations of virtual prototype are performed to obtain the load history of the guide pin. The structural strength assessment of the guide pin is performed to verify a design safety. The fatigue life and damage of the guide pin are predicted using a FEMFAT 4.3h based on the finite element analysis.

용접구조물의 제작시 발생되는 변형사례 모음

  • 배강열;권봉재;김희진
    • Journal of Welding and Joining
    • /
    • v.6 no.1
    • /
    • pp.11-20
    • /
    • 1988
  • 이 글에서는 Butt joint에서 발생되는 가로수축, 각변형 그리고 bowing의 관찰을 통해 mechanism을 서술하였고, box beam, damper blade, bulk head, ball tank, 그리고 cylindrical column 등 실구조물의 변형문제에 접근하여 변형예측, 측정 data제시, 그리고 그 해석을 통해 구조물의 변형 크기를 인식케 하고, 동일한 구조물의 제작에 guide가 되고자 하였다. 변형에 대해서는 일률적인 방지방법이 없기 때문에 우선은 구조물의 제작시마다 변형의 크기와 향상에 대한 예측과 함께 변형계측이 계속되어 data가 축적된다면 차후 그 이용 및 응용 효과는 지대할 것이다.

  • PDF

Functionally upgraded passive devices for seismic response reduction

  • Chen, Genda;Lu, Lyan-Ywan
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.741-757
    • /
    • 2008
  • The research field of structural control has evolved from the development of passive devices since 1970s, through the intensive investigation on active systems in 1980s, to the recent studies of semi-active control systems in 1990s. Currently semi-active control is considered most promising in civil engineering applications. However, actual implementation of semi-active devices is still limited due mainly to their system maintenance and associated long-term reliability as a result of power requirement. In this paper, the concept of functionally upgraded passive devices is introduced to streamline some of the state-of-the-art researches and guide the development of new passive devices that can mimic the function of their corresponding semi-active control devices for various applications. The general characteristics of this special group of passive devices are discussed and representative examples are summarized. Their superior performances are illustrated with cyclic and shake table tests of two example devices: mass-variable tuned liquid damper and friction-pendulum bearing with a variable sliding surface curvature.