• Title/Summary/Keyword: Group size

Search Result 5,125, Processing Time 0.035 seconds

A Meta-Analysis of the Correlates of Resilience in Korean Nurses (한국 간호사의 회복탄력성과 관련된 변인의 메타분석)

  • Kwon, Hye Kyung;Kim, Sin Hyang;Park, Si Hyun
    • Journal of Korean Clinical Nursing Research
    • /
    • v.23 no.1
    • /
    • pp.100-109
    • /
    • 2017
  • Purpose: Nurses' resilience plays an important role in overcoming the challenges that nurses often encounter at clinic, and many factors have been examined which influence on nurses' resilience levels. Through this study, those factors were systematically searched and quantitatively synthesized. Methods: In order to find relevant studies, both English and Korean academic databases were searched, and, finally, a total of 33 articles were identified and included in this analysis. Results: The effect size on the protective variables was large and that of the risk variables was medium. In the protective variable group, the job variable group showed a larger effect size compared to the organizational variable group. Among the protective variables, compassion satisfaction showed the highest contribution on enhancing the resilience level of nurses. In the risk variable group, the personal variable group showed the highest effect size, which was followed by the organizational and job variables. Among the risk variables, the personal stress response showed the highest contribution to decreasing the level of resilience of nurses. Conclusion: This study provides a meaningful data for future studies in terms of developing evidence-based interventions to enhance the levels of resilience among Korean nurses.

The Difference of Left Atrial Volume Index : Can It Predict the Occurrence of Atrial Fibrillation after Radiofrequency Ablation of Atrial Flutter?

  • Kim, Ung;Kim, Young-Jo;Kang, Sang-Wook;Song, In-Wook;Jo, Jung-Hwan;Lee, Sang-Hee;Hong, Geu-Ru;Park, Jong-Seon;Shin, Dong-Gu
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.197-205
    • /
    • 2007
  • Background : The occurrence of atrial fibrillation after ablation of atrial flutter is clinically important. We investigated variables predicting this evolution in ablated patients without a previous atrial fibrillation history. Materials and Methods : Thirty-six patients (Male=28) who were diagnosed as atrial flutter without previous atrial fibrillation history were enrolled in this study. Group 1 (n=11) was defined as those who developed atrial fibrillation after atrial flutter ablation during 1 year follow-up. Group 2 (n=25) was defined as those who has not occurred atrial fibrillation during same follow-up term. Echocardiogram was performed to all patients. We measured left atrial size, left ventricle end diastolic and systolic dimension, ejection fraction and left atrial volume index before and after ablation of atrial flutter. The differences of each variables were compared and analyzed between two groups. Results : The preablation left ventricular ejection fraction (preLVEF) and postablation left ventricular ejection fraction (postLVEF) are $54{\pm}14%$, $56{\pm}13%$ in group 1 and $47{\pm}16%$, $52{\pm}13%$ in group 2. The differences between each two groups are statistically insignificant ($2.2{\pm}1.5$ in group 1 vs $5.4{\pm}9.8$ in group 2, p=0.53). The preablation left atrial size (preLA) and postablation left atrial size (postLA) are $40{\pm}4mm$, $41{\pm}4mm$ in group1 and $44{\pm}8mm$, $41{\pm}4mm$ in group 2. The atrial sizes of both groups were increased but, the differences of left atrial size between two groups before and after flutter ablation were statistically insignificant ($0.6{\pm}0.9mm$ in group 1 vs $-3.8{\pm}7.4mm$ in group 2, p=0.149). The left atrial volume index before flutter ablation was significantly reduced in group 1 than group 2 ($32{\pm}10mm^3/m^2$, $35{\pm}10mm^3/m^2$ in group 1 and $32{\pm}10mm^3/m^2$, $29{\pm}8mm^3/m^2$ in group 2, p<0.05). Conclusion : The difference between left atrial volume index before and after atrial flutter ablation is the robust predictor of occurrence of atrial fibrillation after atrial flutter ablation without previous atrial fibrillation.

  • PDF

A SEM OBSERVATION ON THE EFFICIENCY PREPARATION OF OVAL CANALS USING HAND AND ENGINE-DRIVEN INSTRUMENTS (수동과 엔진구동형 기구를 이용한 난원형 근관의 형성에 관한 주사전자현미경적 관찰)

  • Song, Uk;Hur, Bock;Lee, Hee-Joo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.141-146
    • /
    • 2004
  • The purpose of this study was to evaluate the efficiency of the preparation of oval canals using hand and engine-driven instruments with SEM observation. Thirty single-rooted teeth with oval canal were used in this study. The teeth were divided into 3 groups. In group A the teeth were instrumented up to a size 35 K-file using RC-prep and irrigated with 5% NaOCl between each file size. In group B. the teeth were instrumented with Profile according to the manufacture's instructions using RC-Prep and irrigated with 5% NaOCl between each file size. In group C. the teeth were instrumented with GT file according to the manufacture's instructions using RC-prep and irrigated with 5% NaOCl between each file size. Then. in all teeth. a final flush of 5ml of distilled water delivered for 30s. Canals were dried with sterile standardized paper points. After preparing the canals, the teeth were sectioned along their mesial and diatal surfaces by using low-speed diamond disc. chisel and mallet. Each root section was then dehydrated in graded concentration of alcohol (70, 80, 90, 100%). mounted on an aluminum stub. sputter-coated with gold-palladium and observed with scanning electron microscope (HITACHI S-4200) in middle and apical area. The results of this study were as follows: 1. In the middle area. group B and group C showed less smear layer than group A and it was statistically significant (p < 0.05). 2. In the middle area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 3. In the apical area, group C showed less smear layer than group A. and it was statistically significant (p < 0.05). 4. In the apical area. group A showed greater smear layer than group B. but it was not statistically significant (p > 0.05). 5. In the apical area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 6. In all groups. the middle area was less smear layer than the apical area. and it was statistically significant (p < 0.05).

Differences in retention of the reduction direction depending on dimensions and design CAD/CAM zirconia abutment for implant (Implant에 사용되는 CAD/CAM 전용 zirconia abutment의 표면적과 디자인에 따른 유지력 차이)

  • Nam, Taeg-Mo;Kim, Han-Gon;Kim, Byung-Sik;Lim, Si-Duk
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.317-325
    • /
    • 2010
  • Purpose: The aim of this study is to make some basic materials to find retention force difference based on the total height of CAD/CAM zirconia abutment used for implant, retention force difference based on how to regulate the height of the abutment, retention force difference based on the size and retention force difference based on the design group. Methods: The retention force was measured by being pulled at the speed of 1mm/min after being combined with zirconia block and abutment using Temp-BOND of Kerr. The experiment was done at the research lab of OSTEM in Busan by useing UNIVERSAL TESTING MACHINE on March 3rd, 2010. Results: After analysing the total height and the retention force, p-value had minor difference by 0.01 statistically. Namely, 3mm, 4mm, 5mm had the retention force difference and we could see retention force difference on 3mm and 5mm at the post test. After analyzing how to regulate the height and retention force, p-value had minor difference by 0.000 statistically. Namely, 1mm and 2mm had the retention difference and we could see that 1mm and 2mm with the total height had retention difference. After analyzing the retention force based on the size, p-value had minor retention force difference by 0.000 statistically. Namely, 7 different size had retention force difference and we could see the size 21.9mm, 32.9mm, 32.9mm, 38.4mm, 48.9mm and 54.9mm had retention force difference. Conclusion: Namely 9 different design group had retention difference and we could see that 9 design group with 5.6.7.8 design group and 9 design group with 1.2.3.4. design group had retention force.

A Comparative Study of the Prolonged Effect with Neurectomy & Botox Injection Method on the Gastrocnemius Muscle Hypertrophy (비복근비대의 치료 방법인 신경절단술과 보톡스 주사법의 지속효과 비교에 대한 실험적 연구)

  • Kwan, Sung Tak;Joo, Chun Seung
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.56-61
    • /
    • 2008
  • Purpose: There was no controlled study on botox injection and neurectomy for treatments of muscle hypertrophy. Although many studies have shown the clinical effects of each treatment, it was not able to evaluate and compare the effects of each treatment because there was no comparison of the two treatments under the same experimental condition. Hence, the aim of this study is to com Methods: The study was carried out on 21 rabbits. 9 rabbits received botox injection(botox injection group), and neurectomy was performed to another 9 rabbits (neurectomy group). 3 rabbits did not receive any treatment(control group). To compare and analyze the effects of muscular atrophy, muscle was stained with NADH-TR, and the changes in size of the muscle fiber were examined. And the electromyography was examined. In each group, muscle fiber was stained and electromyography was performed 2, 3, and 6 months after injection or operation. Results: In histological test and electromyography, in the neurectomy group, the size of muscular fiber and amplitude of electromyography decreased until 2 months after neurectomy. And decreased results were maintained with the passage of time. It showed irreversible aspect. On the other hand, in the botox injection group, the decrease in the size of muscular fiber and amplitude of electromyography was observed until 2 months after injection. In 3 months after the injection, it was slowly getting back to original size and had almost recovered by 6 months after the injection. It showed reversible aspect. Conclusion: This study shows researches about clinical effect of botox injection and neurectomy coincide with the results of experiment under the same experimental condition.

Particle Size, Morphology and Color Characteristics of C.I. Pigment Red 57:1 : 2. Effect of Salt Milling Process

  • Seo, Hee Sung;Lee, Hyun Kyung;Yoo, Eui Sang
    • Textile Coloration and Finishing
    • /
    • v.27 no.4
    • /
    • pp.245-260
    • /
    • 2015
  • The effect of salt milling process on the crystal size, morphology, and color characteristics of C.I. Pigment Red 57:1 was studied. The primitive morphology and color properties of the pigment after synthesis were studied in the former series work. The size and morphology of primary particles and the second aggregation features should be considered because they are very important to determine pigment quality. We compared the primary morphology of pigment particles before drying with the secondary aggregated morphology of pigment particles after drying and salt milling process. Morphological properties were investigated by particle size analysis, X-ray diffraction, and scanning electron microscopy and color measurement was carried out. Significant reduction in particle size as well as enhanced crystallite size after salt milling process was observed. This result might give a difference in color of the pigment, turning into brighter and more blue-toned red color. It was revealed that synthesis condition affect the morphology and color of the pigment even after milling. Increase in HCl concentration in the synthesis process enhanced crystal size and quality forming bluer-red pigments but an increase in $CaCl_2$ concentration resulted in more amorphous crystals forming darker-red pigments after salt milling.

Analysis of the Sizing System of Branded Leggings Preferred by Middle-aged Women (중년 여성이 선호하는 브랜드 레깅스 치수체계 분석)

  • Lee, Jeong yim
    • Fashion & Textile Research Journal
    • /
    • v.24 no.5
    • /
    • pp.618-627
    • /
    • 2022
  • This is a basic study to recommend a legging sizing system suitable for middle-aged women. This study aims to explore and analyze the sizing system of branded leggings for middle-aged women. Therefore, 40 pairs of leggings from 20 brands preferred by middle-aged women were first selected to compare their sizing systems. Thus, it was found that the size distribution of legging brands varied significantly, and the number of sizes or the size deviation also varied depending on the brands or products. Second, the adult female age groups were classified as 18-24 years, 25-34 years, 35-44 years, and 45-59 years. Additionally, the distribution of the waist and hip circumferences by age group was compared with the size specifications of the leggings. Leggings with large differences between size specifications and body size distribution were identified in each age group. In the case of women aged 45 to 59, the size distribution suitability of branded leggings was found to be the lowest among the four age groups. Furthermore, it was also found that it is important to reflect the body size distribution, especially the waist circumference, to establish a legging sizing system suitable for women aged 45 to 59 years.

Identification of the Minimum Legible Text Size for Group-View Display of the Main Control Room in Radioactive Waste Facility

  • Jung, Kihyo;Lee, Baekhee;Chang, Yoon;Jung, Ilho;You, Heecheon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.213-219
    • /
    • 2017
  • Objective: The present study identified the minimum legible text size by an experiment for eight combinations of background and text colors, which will be used in designing visual information on group-view display (GVD). Background: Information on minimum legible text size is needed to design the visual information presented on GVD in a radioactive waste control room. Method: The experiment was conducted for 22 male participants (age: mean = 37, SD = 6.7; visual acuity: over 0.8) who were recruited by considering demographic characteristics of current control room operators. Eight combinations of background and text colors were considered and the minimum legible text size was determined for each combination by applying the method of limits, one of psychophysical methods. Results: The minimum legible text size was significantly different in accordance with the combination of background and text colors. Statistical analysis results showed that luminance contrast and color contrast between background and text influenced the minimum legible text sizes. Conclusion: This study concluded that the minimum legible text size is 8 minute of arc for various combinations of background and text colors. Application: The minimum legible text size identified in the present study can be utilized in designing visual information on GVD at the main control room in a radioactive waste facility.

A Meta-Analysis on Effects of Singing Activities for Children (유아대상 동요활동의 효과에 대한 메타분석)

  • Moon, Dong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.218-228
    • /
    • 2017
  • This study covers an investigation using meta-analysis of the factors related to the effects of singing activities for children, focusing on the dissertations conducted for master and doctor degrees and the studies published in academic journals over the past 16 years. Ameta-regression analysis was conducted to examine the changes of the factors in each published year. The analysis results were as follows: Both the entire effect size and the groups of singing activity related factors were revealed to have significant effect sizes. While the group of social factors and the group of cultural & artistic factors showed large effect sizes, the group of psychological & emotional factors appeared to have an intermediate effect size. The sub-factors of the group of social factors were shown to have significantly larger effect sizes than the others, except for the factor of capability of recognizing others. Among the sub-factors, naturally friendly behavior showed relatively larger effect size than the others. In the sub-factors of the group of psychological & emotional factors, self-expression capability and self-control capability showed large effect sizes and stress suppression and emotional intelligence showed intermediate effect sizes. Among the sub-factors of the group of cultural & artistic factors, except for creative capability which showed an intermediate effect size, all of the sub-factors showed large effect sizes. According to the results of the analysis of the trend of the effect size changes in each published year, the trends of the entire effect size and the effect size of each factor, such as the groups of social factors, psychological & emotional factors and cultural & artistic factors, showed that the activity effects increase as the publication year comes closer to the most recent year.

Effects of Tungsten Particle Size and Nickel Addition in DC arc Resistance of Cu-W Electrode

  • Kim, Bong-Seo;Jeong, Hyun-Uk;Lee, Hee-Woong
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.68-72
    • /
    • 2004
  • The performance of copper-tungsten for electrodes used in an ultra high voltage interruption system was evaluated by means of an interruption test, which requires a large-scale apparatus and high cost. In this study, prior to the interruption test, the characteristics of a Cu-W electrode were estimated through the DC arc test, which is a simple, low cost procedure. The DC arc characteristics of a 20wt%Cu-80wt%W electrode were investigated with the change of tungsten powder size distribution and the addition of nickel. In specimens containing a high volume fraction of large sized tungsten particles, the relative density and hardness of sintered Cu-W electrodes increased while the electrical conductivity and the DC arc resistance decreased. Furthermore, the relative density became enhanced with the increase of the amount of nickel while the hardness and electrical conductivity diminished and the DC arc resistance worsened.