• Title/Summary/Keyword: Groundwater discharge rate

Search Result 67, Processing Time 0.021 seconds

Discharge Characteristics of the Chusan Spring, Ulleung Island (울릉도 추산용출소의 용출 특성)

  • Cho, Byong-Wook;Lee, Byeong-Dae
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.6
    • /
    • pp.37-45
    • /
    • 2018
  • The source of Chusan Spring water in the Ulleungdo is the precipitation in the Nari caldera basin, which permeates in the Trachitic pumice and tuff area and moves downward, outflowing at the lithologic boundary between the trachyte and Nari tuff. It is known that the discharge rate of the Chusan Spring is large enough to be used for the small hydroelectric power generation, but the exact discharge rate and hydrogeologic characteristics have not been known. The discharge rates of the Spring were measured 11 times, which ranged from $15,220m^3/d$ to $36,278m^3/d$. The discharge rates, measured by the automatic level recorder, for two-year period, were $20,000{\sim}38,000m^3/d$. The variation of discharge rates did not coincide with rainfall event, but showed daily increases of $3,000{\sim}5,000m^3/d$. The annual discharge rate excluding the evapotranspiration and the surrounding stream discharge corresponded to 70.6% of the annual precipitation of the recharge area. Therefore, meteorological observations at the Nari basin, rather than the Ulleung-do meteorological station, are more appropriate to properly interpret the discharge characteristics of the Chusam Spring and the recharge rate of the basin.

Clustering Analysis with Spring Discharge Data and Evaluation of Groundwater System in Jeju Island (용천수 유출량 클러스터링 해석을 이용한 제주도 지하수 순환 해석)

  • Kim Tae-Hui;Mun Deok-Cheol;Park Won-Bae;Park Gi-Hwa;Go Gi-Won
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.296-299
    • /
    • 2005
  • Time series of spring discharge data in Jeju island can provide abundant information on the spatial groundwater system. In this study, the classification based on time series of spring discharge was performed with clustering analysis: discharge rate and EC. Peak discharges are mainly observed in august or september. However, double peaks and late peaks of discharge are also observed at a plenty of springs. Based on results of clustering analysis, it can be deduced that GH model is not appropriate for the conceptual model of Groundwater system in Jeju island. EC distributions in dry season are also support the conclusion.

  • PDF

Characterizing Groundwater Discharge and Radon Concentration in Coastal Waters, Busan City (부산 해안지역의 물의 라돈 농도와 지하수 유출 특성)

  • Ok, Soon-Il;Hamm, Se-Yeong;Lee, Yong-Woo;Cha, Eun-Jee;Kim, Sang-Hyun;Kim, In-Soo;Khim, Boo-Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.5
    • /
    • pp.53-66
    • /
    • 2011
  • Groundwater which infiltrated in recharge areas discharges in the forms of evapotranspiration, baseflow to streams, groundwater abstraction and eventually flows into the sea. This study characterized radon-222 concentration and electrical conductivity (EC) in coastal groundwater discharge, well groundwater, Ilkwang Stream water, and seawater in the coastal area of Busan Metropolitan City and subsequently estimated groundwater discharge rate to the sea. The median value of Rn-222 concentration is highest in well groundwater (18.36 Bq/L), and then decreases in the order of coastal groundwater discharge (15.92 Bq/L), Ilkwang Stream water (1.408 Bq/L), and seawater (0.030 Bq/L). The relationship between Rn-222 concentration and EC values is relatively strong in well groundwater and then in seawater. However, the relationship is not visible between coastal groundwater discharge and Ilkwang Stream water. The groundwater discharge rate to the sea is estimated as $3,130m^3$/day by using radon mass budget model and $16,788m^3$/day by using Darcy's law.

강변여과수 취수에 따른 지하수위의 계절적인 변동 특성

  • Jeong Jae-Yeol;Ham Se-Yeong;Lee Jeong-Hwan;Kim Hyeong-Su;Ryu Sang-Hon;Kim Tae-Won;Kim Mun-Su
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.68-71
    • /
    • 2006
  • Seasonal fluctuation of groundwater level by pumping amount and stream discharge at the riverbank filtrate site adjacent to the Nakdong River in Daesan-Myeon was characterized. Groundwater level fluctuation shows increase in wet season (June, July, August and September) and decrease in dry season (the other months). Seasonal variation of pumping amount shows similar trend to the groundwater fluctuation due to higher consumption of potable water in summer. The relation of specific capacity, Nakdong River and pumping quantity was analyzed. The logarithmic relationship between specific capacity and the stream discharge gives high correlation coefficient, 0.96. This fact indicates that the increase of stream discharge rate reduces the rate of drawdown in the pumping area in wet season.

  • PDF

Estimating Groundwater Level Change Associated with River Stage and Pumping using Time Series Analyses at a Riverbank Filtration Site in Korea

  • Cheong, Jae-Yeol;Hamm, Se-Yeong;Kim, Hyoung-Soo;Lee, Soo-Hyoung;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.26 no.10
    • /
    • pp.1135-1146
    • /
    • 2017
  • At riverbank filtration sites, groundwater levels of alluvial aquifers near rivers are sensitive to variation in river discharge and pumping quantities. In this study, the groundwater level fluctuation, pumping quantity, and streamflow rate at the site of a riverbank filtration plant, which produces drinking water, in the lower Nakdong River basin, South Korea were interrelated. The relationship between drawdown ratio and river discharge was very strong with a correlation coefficient of 0.96, showing a greater drawdown ratio in the wet season than in the dry season. Autocorrelation and cross-correlation were carried out to characterize groundwater level fluctuation. Autoregressive model analysis of groundwater water level fluctuation led to efficient estimation and prediction of pumping for riverbank filtration in relation to river discharge rates, using simple inputs of river discharge and pumping data, without the need for numerical models that require data regarding several aquifer properties and hydrologic parameters.

Groundwater Recharge and Discharge in the Urban-rural Composite Area (도농복합지역 지하수 함양과 배출에 대한 연구)

  • Lee, Byung-Sun;Hong, Sung-Woo;Kang, Hee-Jun;Lee, Ji-Seong;Yun, Seong-Taek;Nam, Kyoung-Phile
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.2
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

Discharge characteristics of the Seodo Mulgol Spring, Dokdo (독도 서도 물골 지하수의 유출특성)

  • Cho, Byong-Wook;Yun, Uk;Lee, Byeong-Dae;Song, Won-Kyong;Hwan, Jae-Hong;Choo, Chang-Oh
    • The Journal of Engineering Geology
    • /
    • v.21 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • The discharge characteristics of the Seodo Mulgol Spring-the only groundwater-producing area in Dokdo-were evaluated by measurements of discharge rate and electrical conductivity (EC) on five occasions. The Seodo Mulgol Spring is fed by rainfall in upstream areas of the Mulgol cave, and the rainwater of the area moves down along cooling joints developed in trachyandesite II and trachyte, finally discharging at the Mulgol cave. The discharge rate of the Seodo Mulgol Spring varied from 1.12 to 7.02 $m^3/d$ during the study period and EC varied from 2,650 to 3,390 ${\mu}S/cm$, showing a sharp increase during heavy rainfall. The observed variations in discharge rate and EC at the Seodo Mulgol Spring are attributed to the relatively short distance between the recharge area and the Mulgol cave, and to the rapid movement of groundwater through columnar joints developed in trachyandesite II and trachyte. Additional discharge measurements, combined with precise rainfall data, are required at Dokdo to elucidate the discharge characteristics of the Seodo Mulgol Spring.

Analyses of Hydrology and Groundwater Level Fluctuation in Granite Aquifer with Tunnel Excavation (터널 굴착에 의한 화강암 대수층의 수리 수문 및 지하수위변동 분석)

  • Chung, Sang-Yong;Kim, Byung-Woo;Kang, Dong-Hwan;Shim, Byoung-Ohan;Cheong, Sang-Won
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.643-653
    • /
    • 2007
  • Average hydraulic conductivity was $2.64{\times}10^{-8}m/sec$ average RQD was 78%, average porosity was 0.51%, and range of groundwater level was $77.06{\sim}125.97m$ by measured in 8 boreholes at the Surak Mt. tunnel area. Groundwater level of two peaks in the Surak Mt. tunnel area were estimated through linear regression analysis for groundwater level versus elevation. And, average horizontal hydraulic gradient in the Surak Mt. tunnel area was calculated 0.267. Minimum, maximum, and average hydraulic conductivities that estimated by field tests were $5.56{\times}10^{-9}m/sec,\;6.12{\times}10^{-8}m/sec,\;and\;2.64{\times}10^{-8}m/sec$, respectively. Groundwater discharge rates per 1 meter that estimated using minimum, maximum, and average hydraulic conductivities and average horizontal hydraulic gradient were $0.00585m^2/day,\;0.06434m^2/day,\;and\;0.02775m^2/day$, respectively. Pure groundwater recharge rate per unit recharge area was calculated 223.96 mm/yr through water balance analysis. Prediction simulation of groundwater level fluctuation with minimum, maximum, and average hydraulic conductivities were conducted. Discharge rate into the Surak Mt. tunnel for minimum hydraulic conductivity was small, but groundwaer drawdown was highly. Discharge rate into the Surak Mt. tunnel for maximum hydraulic conductivity was higher, but groundwaer level was recovered quickly.

유성지역 소유역에서 추적자(Cl)를 이용한 강우사상에 따른 지표수로부터 기저유출의 분리

  • Jo Seong-Hyeon;Ha Gyu-Cheol;Go Dong-Chan;Jo Min-Jo;Song Mu-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.352-358
    • /
    • 2005
  • This study aims to separate hydrograph into baseflow and event water to calculate baseflow rate during a rainfall in small catchments, Yuseong, Daejeon, The hydrograph of stream during a period with no excess rainfall will decay. The discharge is composed entirely of groundwater contributions. During the period, the Cl concentration of the stream water can be regarded as being in equilibrium with that of the groundwater. Using Cl as a conservative tracer, two-component hydrograph separations were performed from end point of the period to next end point. The required data were obtained by monitoring of the surface water table, along with discharge rate of stream. Cl concentration of rainfall, surface water were measured and recorded. Hydrograph separation, a mixing model using chemical tracer is applied to chemical hydrograph separation technique. These results show that baseflow rates are 31.6% of rainfall in the catchments during study period.

  • PDF

Temporal Variations of Submarine Groundwater Discharge (SGD) and SGD-driven Nutrient Inputs in the Coastal Ocean of Jeju Island (제주도 연안에서 해저 지하수 및 지하수 기원 영양염류 유입량의 시간적 변화)

  • Hwang, Dong-Woon;Koh, Byoung-Seol
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.4
    • /
    • pp.252-261
    • /
    • 2012
  • To determine the temporal variations of submarine groundwater discharge (SGD) and SGD-driven nutrients inputs, we measured the seepage rate and the nutrient concentrations of pore water/groundwater in Bangdu Bay of Jeju Island at two and three month intervals from September 2009 to September 2010. The seepage rate of groundwater ranged from 0 to 330 cm/day (average ~170 cm/day) during the five sampling periods, which increased sharply from high tide to low tide due to changes in hydraulic pressure gradient between water table in land and water sea level in the coastal ocean by the tidal cycles. The submarine inputs of groundwater were also relatively higher in summer than in winter. The nutrient fluxes from SGD were about 90~100%, 70~95%, and 65~100% of the total input (except from open ocean waters) for dissolved inorganic nitrogen (DIN), phosphorus (DIP), and silicate (DSi), respectively, potentially supporting about 0.9~33 g $carbon/m^2/day$ of new primary production in Baugdu Bay. Thus, our study suggests that SGD-driven nutrients may play an important role in the eutrophication and biological production in the coastal ocean of Jeju Island.