• Title/Summary/Keyword: Grounding method

Search Result 293, Processing Time 0.024 seconds

Design of US PCS Duplexer for wireless systems (무선 시스템용 US PCS FBAR Duplexer 설계)

  • Lee, Eun-Kyu;Choi, Hyung-Rim
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.210-211
    • /
    • 2009
  • In this study, we propose characteristics improvement methods according to via hole plating method for FBAR Duplexer with US PCS($T_x$:1850MHz~1910MHz, $R_x$:1930MHz~1990MHz) bandwidth which is used for wireless systems. Also, we designed and fabricated 3.8*3.8*1.8mm size microminiature FBAR Duplexer based on this proposal. First of all, in this study, we fabricated pentagon shape resonators by different size to make filter combination, and their quality factor(Q) are 687 with 6.6% of $k_{eff}^2$. Using this resonators, designed 3*2Type $T_x$ filter and 3*4Type $R_x$ filter. The transmission line, which works as phase shifter, is designed with $210{\mu}m$ in width and 18mm in length Stripline type. Inductor, which is used for matching component, is designed with width of $75{\mu}m$, a technically achievable minimum width. And adopted plating method of filling via hole with conductive epoxy for improved grounding and thermal conductivity. Using these configuration with all of the matching component values, we found Duplexer characteristics of -1.57dB ~ -1.73dB in insertion loss, -56dB in attenuation at 1850MHz~1910MHz of $T_x$ band. Also, found -2.71 dB ~ -3.23dB in insertion loss, -58dB in attenuation at 1930MHz~1990MHz of $R_x$ band.

  • PDF

Transient Overvoltages of Communication Equipment Depending on the Grounding Method of SPD (SPD 접지방식에 따른 통신기기의 과도위험전압)

  • Eom, Ju-Hong;Lee, Tae-Hyung;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.130-138
    • /
    • 2008
  • The tendency of lightning surge to propagate is a eared variously depend on the power system and subject equipment of protection. However, looking into the subject equipment with the lightning surge, the invasion route of lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the route of lightning surge incoming from between the communication lines, the communication line and the ground in addition to the power lines. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground and bypass arrester ground for safety improvement in power lines.

A Study on Improvement of FBAR Duplexer for Wireless Systems (무선 시스템용 FBAR 듀플렉서 특성 개선 연구)

  • Lee, Eun-Kyu;Choi, Hyung-Rim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.388-396
    • /
    • 2010
  • In this study, we propose characteristics improvement methods according to via hole plating method for FBAR Duplexer with bandwidth($T_x4: 1850 MHz ~ 1910 MHz, $R_x$:1930 MHz ~ 1990 MHz) which is used for wireless systems. Also, we designed and fabricated $3.8{\times}3.8{\times}1.8mm$ size microminiature FBAR Duplexer based on this proposal. First of all, in this study, we fabricated pentagon shape resonators by different size to make filter combination, and their quality factor(Q) are 687 with 6.6% of ${k_{eff}}^2$. Using this resonators, we designed $3{\times}2$ Type $T_x$ filter and $3{\times}4$ Type $R_x$ filter. The transmission line, which works as phase shifter, is designed with 210 ${\mu}m$ in width and 18 mm in length Stripline type. Inductor, which is used for matching component, is designed with width of 75 ${\mu}m$, a technically achievable minimum width. And adopted plating method of filling via hole with conductive epoxy for improved grounding and thermal conductivity. Using these configuration with all of the matching component values, we found Duplexer characteristics of -1.57 dB ~ -1.73 dB in insertion loss, -56 dB in attenuation at 1850 MHz ~ 1910 MHz of $T_x$ band. Also, found -2.71 dB ~ -3.23 dB in insertion loss, -58 dB in attenuation at 1930 MHz ~ 1990 MHz of $R_x$ band.

Electromagnetic Interference Suppression Method of Motor Assembly for Aircraft Application (항공용 모터 조립체의 전자기 간섭 감쇠 방안)

  • Kim, Jee-Heung;Ryu, Hong-Kyun;Park, Beom-Jun;Park, Young-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.351-358
    • /
    • 2018
  • In this study, we propose a method of suppressing the leakage noise signal of motor assembly through the test. The motor assembly is mounted on outside of the aircraft to rotate an antenna and must satisfy RE102 requirement on MIL-STD-461F in terms of electromagnetic interference. It is confirmed by RE102 test result hat the leakage noise signal of the equipment occurs due to external influx through the power and control cable and rotation of the motor. And it is ascertained that the part where internal/external physical shielding is difficult to rotate is the leakage path. To reduce the leakage noise signal, the electrical ground reinforcement and the electric shielding structure considering the operation of the equipment is applied and it is verified that the requirement is satisfied. Finally, we verified that required specification are met by applying circular corrugated choke with interlocking shapes and conductive grease to the noise leakage path.

Relative Error Analysis for Measuring Value of Ground Resistance according to Position Variation of Potential Probe) (전위보조전극의 위치변화에 따른 접지저항 측정값의 상대오차분석)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.96-102
    • /
    • 2009
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error for measuring value of ground resistance due to the position of the potential probe, ground resistance were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from l0[m] to 50[m]. Also, the potential probe was located at 30[$^{\circ}$], 45[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$] and 180[$^{\circ}$]. As a consequence, relative error decreased with increasing the distance of potential probe and decreasing the angle between current probe and potential probe. The results could be help to determine the position of potential probe when the ground resistance was measured at grounding system.

A Study on Residual Strength Assessment of Damaged Oil Tanker by Smith Method (Smith법에 의한 손상 유조선의 잔류강도 평가 연구)

  • Ahn, Hyung-Joon;Baek, Deok-Pyo;Lee, Tak-Kee
    • Journal of Navigation and Port Research
    • /
    • v.35 no.10
    • /
    • pp.823-827
    • /
    • 2011
  • The present Common Structural Rules for double hull oil tanker is not included the residual strength, which is one of the functional requirements in design part of Goal-based new ship construction standards (GBS). The GBS will be enforced after July 1, 2016. The requirement related residual strength has the goal to build safe ship even if she has the specified damages due to marine accidents including collision and grounding. In order to assess the residual strength based on risk for structural damages according to GBS, tons of nonlinear FE analysis work taking into account various types of damage will be needed. The Smith's method, a kind of simplified method for the strength analysis is very useful for this purpose. In this paper, the residual strength assessments based on ultimate strength using Smith's method were carried out. The objected ship is VLCC with stranding damage in bottom structures. Also, the results were compared with that of nonlinear FE analysis using three cargo hold model.

An Analysis of Influence Between the Power Feeding Line Insulation and Negative Rail Potential for the DC Ground Fault Protection in the Rubber Wheel System (고무차륜시스템에서의 지락보호를 위한 급전선로 절연과 부극전위와의 영향 분석)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Young;Cho, Sanghoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.577-583
    • /
    • 2013
  • We have analyzed influence of potential rise in negative bus, which caused by decrease of power feeding line insulation, upon protecting method of DC ground protection device which detecting potential rise between negative bus and ground in order to detect ground fault in the rubber wheel system. For this purpose, we proposed negative potential equation between negative bus and ground and calculated negative potential according to system condition changes by estimating power feeding line insulation changes in steel wheel system and rubber wheel system, and equalizing DC power feeding system when ground fault occurred. Also, in order to estimate negative potential of real system, we modeled the rubber wheel system, and simulated normal status, grounding fault occurrence and power feeding line insulation changes. In normal status, negative potential did not rise significantly regardless of vehicle operation. When ground fault occurred, negative potential rose up over 300V regardless of fault resistance. However, we also observed that negative potential rose when power feeding line insulation dropped down under $1M{\Omega}$. In conclusion, our result shows that in case of rubber wheel system unlike steel wheel system, relay will be prevented maloperation and insulation status observation can be ensured when ground over voltage relay will be set 200V ~ 300V.

Analysis of Workload of the Domestic Coastal Ship Duty Officer to Prevent Marine Accidents (해양사고 예방을 위한 국내 연안선 항해당직자의 업무 부하 분석)

  • Yang, Young Hoon;Kim, Hongtae;Jang, Junhyuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.579-587
    • /
    • 2017
  • Objective: The purpose of this study is to measure the workload of Korea coastal ship crew members, to investigate whether they are following work-break time regulations and to identify the main causes of their workload. Background: According to the US Coast Guard, about 33% of human casualties are reported to be due to fatigue, and 30% of marine casualties reported by the British Marine Accident Investigation Agency (MAIB) are attributed to crew fatigue. But the coastal ship are not managed for business hours and breaks despite the harsh environment. Method: The workload of duty crew members on the 100 domestic coastal vessels was measured. It was also investigated whether they are following domestic and international work-break time regulations. Finally, the marine accidents resulted from the fatigue of the crew was analyzed. Results: As a result of workload analysis, the workload on the 42~62% of the vessels exceeded the standard of working time on the related regulation. The workload increased with the number of inbound and outbound ports. Especially, in the system where there are two seafarers, the workload exceeded the working time requirement. As a result of the marine accidents analysis on 100 vessels, it was found that collision and grounding occurred due to fatigue, workload and drowsiness in 7 marine accidents out of 30 marine accidents. Conclusion: It is necessary for the shipping companies to introduce an operation management manual for the management of the crews' workload and reasonable crew arrangement. It is also required for crew members to easily record work times and for shipping companies to manage the record. It would be possible to prevent many marine accidents by providing adequate rest to the crews and flexibly adjusting their working hours. Application: The results of this study can be used as fundamental data to manage crews' fatigue and to make job management manuals.

Verification of Reliability by the Induced Voltage of a Downscaled and Simulated 22.9kV-Y Distribution Line (축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증)

  • Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.26-31
    • /
    • 2015
  • The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at $10{\Omega}$. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.

Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD (중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석)

  • Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.141-149
    • /
    • 2009
  • In this paper, quasi-static FDTD method is implemented by FORTRAN programming, and it is used for analysis of body induced current in middle frequencies. The quasi-static FDTD program is validated by comparing the calculation result with analytic solution of the test model, to which it is difficult to apply conventional FDTD. It is confirmed that the time-step is reduced by $5.68{\times}10^6$ times. Using validated numerical technique, body induced current distribution in high resolution 3-D human model is calculated for 20[kHz] magnetic field exposure and 1[MHz] electric field exposure. Also, the effect of grounding condition of both feet on the distribution and amplitude of the induced current is analyzed. It is expected that this research can be applied to various fields including safety assessment of body induced current and development of diagnosis devices using bio-electricity.