• 제목/요약/키워드: Grounding condition

검색결과 78건 처리시간 0.03초

국내 배전계통의 가공지선 접지조건에 따른 뇌서지 영향 분석 (Analysis of Effect on Lightning Surge according to the Grounding Condition of Overhead Ground Wire in Distribution System)

  • 한준;김철환;서훈철;최선규;이병성
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.331-337
    • /
    • 2014
  • The Korean distribution system consists of overhead ground wire (OHGW), phase conductors and neutral wire. Especially, OHGW is installed over the phase conductors to protect distribution system from the lightning surge. The flashover rate and the magnitude of lightning overvoltage on distribution system can be affected by grounding condition of OHGW such as grounding resistance and grounding interval. In this paper, we conduct an analysis of lightning overvoltage and flashover rate according to the grounding condition of OHGW. The distribution system and lightning surge are modeled by using ElectroMagnetic Transient Program (EMTP). Also, the Monte Carlo method is applied to consider random characteristics of lightning, and the flashover rate is calculated based on IEEE std. 1410. The simulations are performed by changing the grounding resistance and interval of OHGW and the simulation results are analyzed.

전기철도 시스템의 사고 해석 (Fault Analysis for Electric Railway System)

  • 이한민;장동욱;김길동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.291-295
    • /
    • 2005
  • This paper presents the modeling of grounding system on Korean electric railway system. The system model is composed of the catenary system, the grounding-system, the sub-sectioning post, the fault point, the sectioning post, the autotransformer in the substation, and the electric vehicle. The increment of rail-ground voltage may be thought as an amplifier of danger on human body of equipment insulation. The rail-ground voltage on steady state and on fault condition should be under standard limit voltage. To analyze grounding system for steady state and fault condition on Korean railway, modeling for each railway system is performed by 10-port network model. Modeling and analysis of present grounding-system are important to protect human and electronic equipments. The examinations for systematic grounding-system are investigated.

  • PDF

다층 대지구조에서 수직 접지전극의 임계길이 산정 (Computation of the Critical Lengths of the Vertical Grounding Electrode in Multi-Layered Soil Structures)

  • 김기복;조정현;이복희
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.73-80
    • /
    • 2010
  • 접지임피던스는 접지전극의 크기를 증가시켜도 낮아지지 않고, 토양의 특성과 주파수 조건에 따라 접지 임피던스가 최소값을 보이는 접지전극의 길이가 존재하며, 이 접지전극의 길이를 각 토양 특성과 주파수에 따른 임계길이라 한다. 본 논문에서는 대지구조의 조건을 고려하는 새로운 분포정수회로모델을 제안하였으며, 새로이 제안된 해석모델을 적용하여 MATLAB프로그램으로 수직접지전극의 임계길이와 접지임피던스를 해석하였다. 그 결과, 수직접지전극의 임계길이와 접지임피던스의 주파수의존성에 대한 대지구조의 영향이 크며, 접지시스템의 최적 설계를 위해서는 대지구조를 고려하는 것이 바람직한 것으로 밝혀졌다.

도시철도 통합접지망에서의 위험전압에 따른 연접접지봉의 최적 분기간격에 관한 연구 (A Study on the Optimal Divergence Spacing of the Connecting Grounding Rod to the Dangerous Voltage in the Global Earthing Network of Urban Rail Transit)

  • 정호성;박영;김형철;김진희;김재문;조대훈
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1374-1379
    • /
    • 2012
  • Urban rail transit tends to global grounding system in order to control ground potential rise and potential differences between electric equipments. In addition, global grounding system can discharge the large capacity surge current to the ground safely. Since some railway electric equipments are installed all section of line, the global grounding system connected with the connecting grounding wire is more effectively. However, if the fault occurred in the connecting grounding wire area, some dangerous voltage is generated. So, the installation of additional grounding rod will be required. In this study, the global grounding system is simulated using CDEGS program to analyze the divergence spacing of additional ground rod depending on dangerous electric potential characteristics. Grounding net of the each station is modelled in depending on the size of the platform, and the spacing of the connecting grounding rod are compared 50m, 100m, 250m and 400m. Simulation results considering of earth resistivity and underground condition of the connecting grounding wire, spacing of the connecting grounding rod is that less than 250m to spacing of the ground rod was appropriately confirmed.

구조체접지극 활용을 위한 모형블록의 저항률 분석 (Resistivity Analysis of Model Block for Using of Structure Grounding Electrode)

  • 김성삼;정만길;최종규;고희석
    • 조명전기설비학회논문지
    • /
    • 제21권2호
    • /
    • pp.40-45
    • /
    • 2007
  • 건축물의 기초를 구조체접지 및 대용접지극으로 활용하기 위한 기초실험으로 모형블록의 저항률 특성에 관해 검토하였다. 콘크리트와 몰탈의 모형블록을 제작 후 상온과 함수 상태에서 저항률을 측정하였으며, 저항률을 저감시키기 위해 접지저항 저감제를 혼합한 블록을 제작 하여 비교 하였다. 블록의 저항 값은 블록 저항률에 의해 가장 많은 영향을 받으며, 블록 저항률이 동일하거나 유사한 값일 때 대지저항률 값의 차이만큼 접지저항 값의 차이가 발생하였다.

서울메트로 PSD장비 탄소접지모듈 설치 사례 (The example of the Carbon Grounding Modules installation for PSD systems at a subway station, Seoulmetro)

  • 정용기;현용섭;송병권;김용협
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.292-298
    • /
    • 2008
  • Seoul Metro and Seoul Metropolitan Rapid Transit Corp. have started installing screen doors at subway platforms to improve the environment of subways and prevent passengers' accidents since 2006. They are still installing screen doors at subway platforms and Metropolitan Rapid Transit Corporations in other areas are also proceeding with installment of screen doors or making preparations for it. Grounding is necessary for installing PSD systems. In case that PSD grounding is connected with existing electrical equipment grounding system, it was decided to install separate grounding for safe operation of PSD system and passenger safety. However, it's very difficult to install new grounding at the subway station compound. A way to improve this condition is that we proceed with grounding by composing grounding station by carbon grounding rod. This paper will mainly deal with how to design and construct carbon ground rod, which has been applied to PSD system grounding since 2006, including its experimental examples. In this paper, ways to secure ground resistance below 5 ohms, which is resistance necessary for PSD grounding, and to compose grounding system were also discussed. Furthermore, a ground test to check the ability to fulfill a role of PSD grounding system was conducted. As a result of applying carbon grounding module, PSD system is being operated without any problem and the installment of PSD system will be continuously expanded in the future. It's also thought that a way to integrate grounding of each functional room which has been installed at the subway station compound and to arrange equipotential grounding should be reviewed and performed promptly.

  • PDF

직선형 접지전극의 임계길이의 산정 (Computation of Critical Length for Linear Grounding Electrodes)

  • 김기복;이복희;조정현
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.67-74
    • /
    • 2009
  • 뇌전류와 같이 고주파성분을 함유한 서지전류나 전자통신기기의 전자기장해를 유발하는 고주파 이상전류에 대하여 접지전각은 주파수에 의존적인 상당히 복합적인 입피던스의 특성을 보인다. 접지전극의 접지임피던스는 접지전극의 크기를 증가시켜도 낮아지지 않고, 대지의 특성과 주파수 조건에 따라 접지임피던스가 최소값을 보이는 접지전극의 길이가 존재하며, 이 접지전극의 길이를 대지의 특성과 주파수 조건에 대한 임계길이라 정의한다. 본 논문에서는 분포정수회로모델을 이용하여 수직접지전극과 수평접지전극의 임계길이를 산정하였으며, 실험결과와의 비교를 통해 타당성을 확인하였다.

수직접지전극의 임계길이 산정 (Computation of Critical Length for Vertical Grounding Electrode and Counterpoise)

  • 이복희;조정현;이봉;김종호;이승주;이강수;김기복;김태기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1491_1492
    • /
    • 2009
  • The impedance of a vertical grounding electrode is not lowered by expanding the dimension of the grounding electrode, and the length of thr vertical grounding electrode which shows the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical length. In this paper, the critical lengths for the vertical grounding electrodes are calculated by using the distributed parameter circuit model. The adequacy of the simulations has been confirmed by comparing the simulated results with the measured results.

  • PDF

봉상접지극의 과도임피던스 특성 (Transient Impedance Characteristics of Grounding Rods)

  • 김일권;김점식;송재용;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

지중송배전계통에서 과도상태시 공통접지의 영향 분석 (Analysis of Common Grounding Effect during the Transient State in Underground Transmission and Distribution Systems)

  • 임광식;이종범
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.191-197
    • /
    • 2008
  • This paper describes the effect of transient state in underground transmission and distribution lines installed together in the same tunnel. Two systems installed in the same tunnel are operated by the common grounding. This paper analyzed that how much one of the two kinds of systems influences the other systems during the transient state by EMTP/ATPDraw. Single line-to-ground fault and lightning surge were selected in transient state condition. These cases were simulated variously according to the variation of common grounding magnitude, fault location and lightning surge magnitude. It is evaluated that the analyzed results will be used for establishment and operating materials of common grounding in the same tunnel.