• 제목/요약/키워드: Ground Water

검색결과 3,611건 처리시간 0.042초

농촌 소유역에서의 지표수와 지하수의 영양물질 농도 비교 (Comparison of the nutrient concentration between surface water and ground water in a rural watershed)

  • 송철민;김진수;오광영;권성일
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.157-161
    • /
    • 2007
  • Nutrients were investigated for surface water, bottom sediment and ground water in a rural watershed from January 2006 to March 2007. The concentrations of TN and $NO_3-N$ in ground water were higher than those in surface water due to fertilization on cabbage upland neighboring a river during March to August, but lower than those in surface water during September to February. However, the concentrations TP and $PO_4-P$ in ground water were lower than those in surface water. The concentrations of TP and $PO_4-P$ in surface water was lower than those in bottom sediment. The TP concentration in the bottom greatly decreased during rainy season. due to flush sediment of bottom, and then gradually increased.

  • PDF

지표수와 지하수의 최적 연계운영 (Optimal Conjunctive Use of Surface and Ground Water)

  • 이재응
    • 한국수자원학회논문집
    • /
    • 제35권4호
    • /
    • pp.367-374
    • /
    • 2002
  • 본 연구에서는 지표수와 지하수를 최적 연계 운영하여 장차 다가올 물 부족에 대응할 수 있는 용수 공급 방안을 검토하였다. 최적 지표수, 지하수 연계운영 모형은 용수공급으로 인한 순편익을 최대화하도록 이산미분동적계획법을 사용하여 개발하였다. 시범유역으로 양양 남대천을 선정하여 모형을 적용한 결과, 지표수만 사용하여 용수를 공급하는 것에 비하여 용수공급 신뢰도가 뛰어남을 확인할 수 있었다.

통계분석을 이용한 지하수위 변동 특성 분류

  • 문상기;우남칠
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.155-159
    • /
    • 2001
  • A study on multivariate statistical classification of ground water hydrographs was conducted. The vast data of national ground water monitoring network (78 sites of alluvium) were used. 6 factors were selected to classify the ground water level change. Factor analysis was proved to be useful tool for classifying vast hydrogeological data.

  • PDF

유역물수지 분석에 의한 지하수 함양량 추정 (Estimation of the Quantity of Ground Water Recharge using the Water Balance)

  • 박찬제;김태철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.265-268
    • /
    • 2002
  • The ground water regime analysis method, numerical analysis method, water budget method, and baseflow analysis method have been used for estimating ground water recharged quantity. This study, adapting water budget concept of unsaturated zone, and saturated zone of the DAWAST model, proposed a new method to estimate ground water recharged quantity.

  • PDF

지하댐 운영시 발생하는 염수침입 저감기법에 관한 연구 (A Study for Reducing Sea Water Intrusion in the Ground Water Dam Operation)

  • 윤상훈;박재현;박창근
    • 한국수자원학회논문집
    • /
    • 제37권2호
    • /
    • pp.97-108
    • /
    • 2004
  • 최근 들어 도서지역이나 해안지역의 제한된 수자원을 보다 효과적으로 사용하기 위하여 지하댐을 이용한 지하수자원 개발 방안이 제시되고 있다. 그러나 해안선에 인접한 지하댐의 경우 과도한 지하수 양수는 대수층의 지하수위를 저하시켜 결국 염수침입이라는 심각한 문제를 발생시키게 된다. 염수침입은 대수층의 지하수위 하강에 기인하므로 본 연구에서는 지하댐 하류에 함양정(Recharging well)을 설치하여 대수층의 지하수위를 상승시킴에 따른 염수침입 저감효과를 분석하였다. 이 방안을 쌍천유역에 적용하였으며, 이를 위해 염분의 이송ㆍ확산을 분석할 수 있는 SUTRA(Saturated-Unsaturated Transport) 수치모형을 적용하였다. 그 결과 지하댐 하류지역에 대한 함양기법이 양수정 염분 저하에 매우 효율적인 방법임이 증명되었고, 염해저감을 위한 함양정 운영시 차수벽으로부터 40∼60m거리에 함양정을 설치하고 함양률을 총 양수량의 6∼7%정도로 하여 운영을 할 때 가장 효율적으로 염해를 저감시킬 수 있다는 결론을 얻을 수 있었다.

열교환방식에 따른 지열히트펌프의 난방특성에 관한 연구 (A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods)

  • 차동안;권오경;박차식
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2012
  • The objective of this study is to investigate the influence on the heating performance for a water-to-water 10RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The heating capacity and COP of the heat pump increased with increasing ground heat source temperature. As a result, compared to a refrigerant switching method, the water switching method with counter flow improves the heating capacity and COP by approximately 5% in average, respectively.

지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구 (An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System)

  • 임효재;권정태;김창업;공형진;박성구
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

지상과 수중에서 뇌졸중 환자의 호흡기능 변화 (Changes in the Respiratory Function of Stroke Patients on the Ground and Immersed under Water)

  • 김주승;박민철
    • PNF and Movement
    • /
    • 제16권3호
    • /
    • pp.389-395
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate whether the respiratory function of patients with stroke was different on the ground and under water. Methods: We recruited 14 adults who had experienced a stroke (12 male, 2 female) for our study. We measured forced vital capacity, forced expiratory volume at one second, maximum inspiratory pressure, and maximum expiratory pressure when the participants breathed on the ground and under water. On the ground, the participants were safely supported using a table and chair and were measured in a standing posture. For measuring under water, the participants were immersed in water in a standing position to clavicle height. The participants were measured while standing, and the assistant supported them when they needed help. The collected data were analyzed by a paired t-test. Results: Forced vital capacity and forced expiratory volume at one second were significantly lower in water than on the ground when breathing at maximum. Maximum inspiratory pressure was not significantly different when standing on the ground or in water, but maximum expiratory pressure was significantly higher in water than on the ground. Conclusion: It has been confirmed that the hydrostatic pressure affecting stroke patients immersed in water affects the forced expiratory volume at one second while reducing the forced vital capacity and increasing the maximum expiratory pressure.

Comparative assessment of surface and ground water quality using geoinformatics

  • Giridhar, M.V.S.S.;Mohan, Shyama;Kumar, D. Ajay
    • Advances in environmental research
    • /
    • 제9권3호
    • /
    • pp.151-160
    • /
    • 2020
  • Water quality demonstrates physical, chemical and biological characteristics of water. The quality of surface and groundwater is currently an important concern with population growth and industrialization. Over exploitation of water resources due to demand is causing the deterioration of surface water and ground water. Periodic water quality testing must be carried out to protect our water resources. The present research analyses the spatial variation of surface water and groundwater in and around the lakes of Hyderabad. Twenty-Seven lakes and their neighboring bore water samples are obtained for water quality monitoring. Samples are evaluated for specific physico-chemical parameters such as pH, Total Dissolved Solids (TDS), Cl, SO4, Na, K, Ca, Mg, and Total Hardness (TH). The spatial variation of water quality parameters for the 27 lakes and groundwater were analysed. Correlation and multiple regression analysis were carried out to determine comparative study of lake and ground water. The study found that most of the lakes were polluted and this had an impact on surrounding ground water.

주거용 건물 지열원 멀티 히트펌프시스템의 지열순환펌프 가변유량제어에 관한 실증연구 (An Experimental Study on Variable-Speed Control of an Ground-Water Circulation Pump for a Ground Source Multi-Heat Pump System)

  • 송수원
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.443-449
    • /
    • 2013
  • The purpose of this study is to propose an enhanced variable-speed control method of ground-water circulation pumps using inlet and outlet ground-water temperature difference and analyze its effect for the ground source multi-heat pump system installed in a single-family house. As a result, it has shown to significantly reduce the electricity use of ground-water circulation pump and improve overall system Coefficient of Performance (COP) due to the proposed variable-speed control under partial load conditions after oversized and inefficient single-speed pump retrofit.