• 제목/요약/키워드: Ground Water

검색결과 3,602건 처리시간 0.032초

Assessment of health risk associated with arsenic exposure from soil, groundwater, polished rice for setting target cleanup level nearby abandoned mines

  • Lee, Ji-Ho;Kim, Won-Il;Jeong, Eun-Jung;Yoo, Ji-Hyock;Kim, Ji-Young;Lee, Je-Bong;Im, Geon-Jae;Hong, Moo-Ki
    • 한국토양비료학회지
    • /
    • 제44권1호
    • /
    • pp.38-47
    • /
    • 2011
  • This study focused on health risk assessment via multi-routes of As exposure to establish a target cleanup level (TCL) in abandoned mines. Soil, ground water, and rice samples were collected near ten abandoned mines in November 2009. The As contaminations measured in all samples were used for determining the probabilistic health risk by Monte-Carlo simulation techniques. The human exposure to As compound was attributed to ground water ingestion. Cancer risk probability (R) via ground water and rice intake exceeded the acceptable risk range of $10^{-6}{\sim}10^{-4}$ in all selected mines. In particular, the MB mine showed the higher R value than other mines. The non-carcinogenic effects, estimated by comparing the average As exposure with corresponding reference dose were determined by hazard quotient (HQ) values, which were less than 1.0 via ground water and rice intake in SD, NS, and MB mines. This implied that the non-carcinogenic toxic effects, due to this exposure pathway had a greater possibility to occur than those in other mines. Besides, hazard index (HI) values, representing overall toxic effects by summed the HQ values were also greater than 1.0 in SD, NS, JA, and IA mines. This revealed that non-carcinogenic toxic effects were generally occurred. The As contaminants in all selected mines exceeded the TCL values for target cancer risk ($10^{-6}$) through ground water ingestion and rice intake. However, the As level in soil was greater than TCL value for target cancer risk via inadvertent soil ingestion pathway, except for KK mine. In TCL values for target hazard quotient (THQ), the As contaminants in soil did not exceed such TCL value. On the contrary, the As levels in ground water and polished rice in SD, NS, IA, and MB mines were also beyond the TCL values via ground water and rice intake. This study concluded that the health risks through ground water and rice intake were greater than those though soil inadvertent ingestion and dermal contact. In addition, it suggests that the abandoned mines to exceed the risk-based TCL values are carefully necessary to monitor for soil remediation.

공동주택에서 지열 냉난방 시스템 적용시 경제성 분석 (Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment)

  • 박용부;박종배;임해식;백성권
    • 한국지반환경공학회 논문집
    • /
    • 제8권3호
    • /
    • pp.11-18
    • /
    • 2007
  • 본 연구에서는 파급효과가 큰 공동주택에서 지열 냉난방 시스템의 경제성을 아파트 분양평형, 운전시간, 냉난방 및 급탕 설치형태별로 구분하여 초기 공사비 증가, 운전비 절감액, 초기 투자비 회수기간등을 산정하였다. 냉난방 및 급탕 운전시간이 많을수록 초기 공사비 증가액에 비해 운전비용 절감액이 커 초기 투자비 회수기간이 단축되었다. 전용면적이 클수록 투자회수 기간이 길었으며 냉난방 및 급탕 설치형태에서는 냉난방을 지열원, 급탕을 폐열회수한 경우가 초기 투자 회수기간이 가장 짧았다. 기존 시스템(패키지 에어콘, LNG 난방 및 급탕)에 비해 냉난방, 급탕을 모두 지열로 이용하는 경우, 냉난방은 지열, 급탕은 폐열을 이용하는 경우, 냉난방은 지열, 급탕은 LNG인 경우에 공사비가 $m^2$당 각각 약 72,000원, 66,900원, 62,300원 정도 증가하였다.

  • PDF

음용수질 기준과 관리방안 (Recent Development of Drinking Water Quality Standard and its Application)

  • 권숙표
    • 환경위생공학
    • /
    • 제7권2호
    • /
    • pp.83-94
    • /
    • 1992
  • Recently water demand is increasing as the industry prospers. The increase of water demand is followed by the increase of wastewater discharge which pollutes rivers and ground water extensively. These rivers, reservoirs and ground water are sources for drinking water and their contamination affects the quality of water supply and other potable water. In Korea there are 776 water treatment plants which supply drinking water from main rivers or reservoirs. Rivers are the biggest water source for drinking water is being contaminated, the innovation of treatment process is needed. The construction and operation of water supply facilities is under the control of the Ministry of Construction and the water supply offices of cities and provinces. However, drinking water quality is under the control of the bureau of sanitation in the Ministry of Health and Social Affairs. There are 33 items in drinking water quality standards of Korea. Trihalomethanes, Selenium, Diazinone and other three of pesticides have been included lately, The Ministry of Health and Social Affairs is planning to enhance. the level of $VOC_S$(Vola-tile Organic Compounds) standard. Drinking water quality standard is the goal to protect the quality of supply water and ground water. In order to protect the source water from domestic or industrial water, technological improvement and adequate investment should be urgently made. The ultimate goal of drinking water quality is safety and health of consumers. The more stringent the standard are, the better the water quality will be. As the drinking water quality standards become more stringent this year, various and positive solutions by the authorities concerned must be prepared.

  • PDF

여과수열원 히트펌프를 이용한 온실난방기술 개발 (Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump)

  • 문종필;이성현;강연구;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

나노섬유를 이용한 동전기 지반개량에 관한 특성 (Characteristics on Electroosmosis Ground Improvement Using Nano-geosynthetics)

  • 안광국;정구식;이준대
    • 한국지반환경공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.59-63
    • /
    • 2009
  • 본 연구는 지반개량공법에 사용되는 동전기 공법에서 나노섬유를 전극재로 사용하여 지반개량효과 및 나노섬유에 대한 전극재로서의 대체가능성을 확인하였다. 이를 위해 Electrokinetic cell을 제작하여 나노섬유를 PBD에 삽입 후 교반된 Kaolin clay에 전기삼투를 적용한 후 실험전후의 침하량, 함수비, 압밀배수량, 전단강도에 대한 지반개량효과를 비교 분석하였다. 또한 전기삼투실험은 전극거리와 전압경사를 변화시키면서 실험을 수행하였으며, 그 결과로 전압경사증가 및 전극거리가 감소할수록 침하량, 전단강도, 압밀배수량은 증가하였고 함수비는 감소하는 것으로 나타났다. 이는 지반개량을 위한 동전기 적용시 사용되는 전극재의 소재로 나노섬유가 충분한 가능성이 있는 것으로 판단된다.

  • PDF

낙동강 하구 염습지의 갈대서식 환경 특성 (Environmetal Characteristics of Reed Habitat in Nakdong Estuary Saltmarsh)

  • 류성훈;김경회;이인철
    • 해양환경안전학회지
    • /
    • 제22권2호
    • /
    • pp.187-194
    • /
    • 2016
  • 본 연구에서는 하구 염습지 생태계 복원 및 조성을 위한 기초적 연구로서, 낙동강 하구 사주섬인 진우도에 서식하는 갈대의 서식환경 특성을 파악하기 위하여 저질의 함수량, 입도분포, pH, 영양염 농도($NH_4-N$, $PO_4-P$), 지하수위, 지반고, 갈대 개체수 및 최대 높이 등의 조사를 실시하였다. 조사결과 연구대상 지역의 저질 입경 및 함수량이 갈대 서식환경에 미치는 영향은 적은 것으로 나타났으며, pH는 식생대와 비식생대 정점의 차이가 없었고, $NH_4-N$$PO_4-P$ 농도도 정점별 차이가 없었다. 식생대 영역에서 해안선 쪽으로 갈수록 지반고가 낮으며 개체수는 감소하였고, 지하수위는 높게 나타났다. 따라서 낙동강 하구 염습지의 갈대서식 환경에 영향을 미치는 주요인자는 지반고와 지하수위가 크게 기여하는 것으로 나타났다.

용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성 (Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate)

  • 조찬용;최종민
    • 신재생에너지
    • /
    • 제7권4호
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

통계적 분석을 이용한 간이급수시설의 오염원에 관한 연구 (A Study on the Pollution Sources of Simple water Supply Piped System using Statistical Analysis)

  • 이홍근;김현용;백도현;김지영;이태호
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.56-67
    • /
    • 1999
  • This study was performed to suggest the basic data and plans for the establishment of safe water supply plans in simple water supply piped system in the rural areas. In 4 different places, 24 points of water sources 36 points of taps from water sources were sampled. Of the whole 60 points, 55 points were ground water and 5 points were surface water. 14 items were measured for the analysis of water quality on each samples. The measured items were analyzed again by statistical method ; cluster analysis and principle components analysis. The results of this study are as followed. 1) In water quality analysis on water sources, 4 items, bacteria, E.coli, NH3-N and Fe exceed the standard. Of 24 points, 20 points(83%) on bacteria, 1 point(4%) on NH3-N and Fe exceed the standard. 2) In water quality analysis on near and remote taps, 4 items, bacteria, E.coli, NH3-N and Fe , exceed the standard. Of 36 points, 20 points (81%) on bactria, 1 pint(3%) on NH3-N and Fe exceed the standard. 3)Cluster analysis on water quality shows the differences by the kinds of water sources, geographical characteristics and distance from water sources. 4) Principle components analysis on ground water shows that Factor 1 and Factor 3 are natural fluctuation by the content of soil. Also, Factor 2 and Factor 4 are penetration of pollutants to underground. Therefore, it is needed to take deeper ground water in order to prevent from pollution in the areas which have ground water as water source . 5) Principle components analysis on surface water shows that Factor 1 is penetration of vacteria from surface to water source when rainfalls. Also, Factor 2 is fluctuation of water quality by the geographical characteristics. Therefore, the counterplans against non-point pollution source must be taken. Filtration and disinfection facilities are needed in the areas which have surface water as water source.

  • PDF

지반함몰 방지를 위한 지하수 재주입 실험적 연구 (An Experimental Study on Recharge Well Technology for Prevention of Ground Collapse)

  • 신은철;박춘성
    • 한국지반환경공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.35-43
    • /
    • 2017
  • 지하수위 저하를 방지하기 위한 방법으로 지반 굴착에 따라 배출된 지하수를 대상 지반에 다시 재주입함으로써 흙막이 벽체 배면의 지반함몰 및 침하를 방지하는 방법에 관한 연구이다. 지하수 재주입에 따른 흙막이 벽체 배면의 지반함몰 및 침하를 분석하기 위해 지하수 재주입 여부와 흙막이 벽체 배면으로부터 거리 등 조건을 달리하며 재주입정 위치별 효과를 확인할 수 있는 실내모형실험을 수행하였다. 실험을 통해 지하수위에 영향을 미치는 인자와 흙막이 벽체 배면의 지반함몰 및 침하경향을 분석하고, 지하수 재주입에 따른 지반함몰 방지효과에 대한 연구를 수행하였다. 지하수위의 영향을 고려한 침하분석 결과, 흙막이 전면을 굴착할 때 지하수위 저하에 따라 지표면 침하가 발생, 흙막이 벽체 배면에서 최대가 된다. 또한 흙막이 길이를 기준으로 흙막이 벽체 배면으로부터 재주입정 위치별 거리 비에 따라 침하량이 달라지는 것으로 분석되었다. 지하수의 영향에 의한 지반함몰 및 침하를 방지하기 위한 방법으로 흙막이 벽체 배면으로부터 가까운 위치에 지하수를 재주입 할 때 지반함몰 및 침하 방지 효과가 크고 최대 침하영향거리도 감소하는 것으로 분석되어 지하수 재주입정 공법의 지반함몰 방지효과를 확인하였다.