Browse > Article
http://dx.doi.org/10.14481/jkges.2017.18.5.35

An Experimental Study on Recharge Well Technology for Prevention of Ground Collapse  

Shin, Eunchul (Department of Civil and Environmental Engineering, College of Urban Sciences, Incheon National University)
Park, Chunsung (Department of Civil and Environmental Engineering, College of Urban Sciences, Incheon National University)
Publication Information
Journal of the Korean GEO-environmental Society / v.18, no.5, 2017 , pp. 35-43 More about this Journal
Abstract
It is a method of suppressing back ground subsidence by re-injecting groundwater back to the target ground and recovering the underground water level. In order to analyze the subsidence of the back ground due to maintaining the underground water level, indoor model experiments were conducted. Through this study, the factors influencing on the groundwater and the tendency of subsidence back ground by experiments were analyzed and the effect of ground subsidence by reinfusion of groundwater was also investigated. As a result of the subsidence analysis with considering only the influence of the underground water level, the settlement of the ground occurs as the underground water level at the time of ground excavation goes down. The closer to the back of the retaining wall, the maximum settlement occurred. Moreover, it was analyzed that the influence distance where subsidence occurs from retaining wall to the point of about 1.8 H on the basis of the ground collapse. The most effective location of water reinjection is the closet location to the back of braced-cut wall for reducing the groundwater down and also minimizing the ground settlement.
Keywords
Ground collapse; Recharge well technology; Underground water level; Ground settlement;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김윤승 (2015), 싱크홀 방지를 위한 환경영향평가 개선 방안 연구, 한국환경정책.평가연구원.
2 김창룡 (2012), 대심도 지하도로 설계기준 제정 연구, 한국건설기술연구원.
3 이송 (1999), "국내 적용되고있는 흙막이 구조물의 관리기준치에 대한 신뢰도 분석", 대한토목학회논문집 제19권, pp. 479-487.
4 Gabr, M. A., Williamson, A., Sabodish, M. and Bowders, J. J. (1999), BTEX extraction from clay soil using prefabricated vertical drains, Journal of Geotechnical and Geoenvironmental Engineering, 125(3), pp. 615-618.   DOI
5 Maliva, R. G., Coulibaly, K., Guo, W. and Missimer, T. (2011), Confined aquifer loading implications for ground water management, Ground water, 49(3) pp. 302-304.   DOI
6 Shen., Shui-Long. and XU Ye-Shuang. (2011), Numerical evaluation of land subsidence induced by groundwater pumping in Shanghai, Canadian Geotechnical Journal, Vol. 48.9, pp. 1378-1392.   DOI
7 Zhang, X. S., Wang, J. X., Wong, H., Leo, C. J., Liu, Q., Tang, Y. Q., Yan, X. L., Sun, W. H., Huang, Z. Q. and Hao, X. H. (2013), Land subsidence caused by internal soil erosion owing to pumping confined aquifer groundwater during the deep foundation construction in Shanghai, Natural hazards, Vol. 69.1, pp. 473-489.   DOI