• 제목/요약/키워드: Ground Plate

검색결과 444건 처리시간 0.023초

Can a Skier Make a Circular Turn without any Active Movement?

  • Youn, Sun-Hyun
    • Journal of the Korean Physical Society
    • /
    • 제73권10호
    • /
    • pp.1410-1419
    • /
    • 2018
  • A skier's motion was analyzed by a simple model consist of point mass m and a single rod connected to a single ski plate. We studied the conditions for the stable ski turn as functions of the linear velocity and the radius of the turn. The solutions for the stable ski turn in our model do not require any extra skier's movement to complete a stable circular turn. The solution may then give the skier the most comfortable skiing method without any active movement to control the ski. The generalized force supporting the point mass from the ski plate was calculated. We obtained the force from the ground (rebound force) without any geometrical structure of the ski plate. Adding an active movement to the direction of the ski plate, the conditions for the stable ski turn were also analyzed. Our result gives some insight for the skier who wants to develop technique.

Analysis of circular tank foundation on multi-layered soil subject to combined vertical and lateral loads

  • Hesham F. Elhuni;Bipin K. Gupta;Dipanjan Basu
    • Geomechanics and Engineering
    • /
    • 제32권6호
    • /
    • pp.553-566
    • /
    • 2023
  • A circular tank foundation resting on the ground and subjected to axisymmetric horizontal and vertical loads and moments is analyzed using the variational principles of mechanics. The circular foundation is assumed to behave as a Kirchhoff plate with in-plane and transverse displacements. The soil beneath the foundation is assumed to be a multi-layered continuum in which the horizontal and vertical displacements are expressed as products of separable functions. The differential equations of plate and soil displacements are obtained by minimizing the total potential energy of the plate-soil system and are solved using the finite element and finite difference methods following an iterative algorithm. Comparisons with the results of equivalent two-dimensional finite element analysis and other researchers establish the accuracy of the method.

Seismic Performance of Gravity-Load Designed Post-Tensioned Flat Plate Frames (중력하중으로 설계된 포스트텐션 플랫플레이트 골조의 내진성능)

  • Han, Sang-Whan;Park, Young-Mi;Rew, Youn-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제14권3호
    • /
    • pp.31-38
    • /
    • 2010
  • The purpose of this study is to evaluate the seismic performance of gravity-designed post tensioned (PT) flat plate frames with and without slab bottom reinforcement passing through the column. In low and moderate seismic regions, buildings are often designed considering only gravity loads. This study focuses on the seismic performance of gravity load designed PT flat plate frames. For this purpose, 3-, 6- and 9-story PT flat plate frames are designed considering only gravity loads. For reinforced concrete flat plate frames, continuous slab bottom reinforcement (integrity reinforcement) passing through the column should be placed to prevent progressive collapse; however, for the PT flat plate frames, the slab bottom reinforcement is often omitted since the requirement for the slab bottom reinforcement for PT flat plates is not clearly specified in ACI 318-08. This study evaluates the seismic performance of the model frames, which was evaluated by conducting nonlinear time history analyses. For conducting nonlinear time history analyses, six sets of ground motions are used as input ground motions, which represent two different hazard levels (return periods of 475 and 2475 years) and three different locations (Boston, Seattle, and L.A.). This study shows that gravity designed PT flat plate frames have some seismic resistance. In addition, the seismic performance of PT flat plate frames is significantly improved by the placement of slab bottom reinforcement passing through the column.

Analyzing Method of Deformation of Model Ground in Plane Strain (평면변형율 상태에 있는 모형지반의 변형해석법)

  • 임종철;주인곤
    • Geotechnical Engineering
    • /
    • 제8권1호
    • /
    • pp.29-40
    • /
    • 1992
  • One of the most important things to analyze model ground test in plane strain is to observe deformation, accurately, In this paper, the analyzing method of ground deformation by using photos of points on membrane attached on transparent acryle plate of side wall of model ground box is described. First order 4-node isoparametric elements are used to calculate strains of ole cents.

  • PDF

Behavior of SCP Improved Ground with Installation of Sheet Pile (Sheet Pile 설치에 따른 SCP개량지반의 거동)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo
    • Journal of Industrial Technology
    • /
    • 제22권B호
    • /
    • pp.211-218
    • /
    • 2002
  • The paper is to show the behavior of composit ground which is installed with sheet pile in soft soil improved by sand compaction pile. The results of load-settlement relationship, earth pressure, stress concentration characteristics, and final water content were obtained by centrifuge model test. Two cases of tests, installation of sheet pile on the corner and both side of the loading plate for the improved SCP ground which was designed twice of the footing width, were performed for the tests under the vertical and horizontal loading and both side of corner. Finite element program(CRISP) for sand compaction pile using elasto-plastic model and numerical analysis for soft soil using modified cam-clay constitutive equation were compared and analized with the results of model tests. The result of analysis show the increased bearing capacity of soil after, SCP and sheet pile was installed.

  • PDF

Seismicity of Peninsular Malaysia due to intraplate and far field sources

  • Loi, Daniel W.;Raghunandan, Mavinakere E.;Swamy, Varghese
    • Earthquakes and Structures
    • /
    • 제10권6호
    • /
    • pp.1391-1404
    • /
    • 2016
  • Peninsular Malaysia lying on the stable Sunda Plate has traditionally been considered safe with low to moderate seismicity. However, far field Sumatran mega-earthquakes have been shown to be capable of triggering ground motions felt in high rise structures in the major Malaysian cities while seismic impact from local earthquakes of moment magnitude 3.8 have reportedly induced nominal structural damages to nearby buildings. This paper presents an overview of the recent seismic activities in and around Peninsular Malaysia with reference to prominent earthquakes generated by far field interplate and local intraplate sources. Records of ground motion data and seismic hazard assessment (SHA) results available in the literature have been analyzed and discussed. The peak ground acceleration (PGA) values from historical records for few local intraplate events were observed to be higher than those for the events from Sumatran Subduction Zone. This clearly points to the need for a detailed and comprehensive SHA incorporating both far field and local sources. Such an analysis would contribute the knowledge required for secure and reliable infrastructure design and safeguard the Malaysian people and economy.

The Field of Power/Ground Planes influenced by the HPEM Source, and its Damage Reduction

  • Kahng, Sung-Tek;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.406-410
    • /
    • 2012
  • This paper looks into the field inside the wide rectangular box structure that is excited by the High Power Electromagnetic(HPEM) source as a potential threat to electric grid and communication networks causing malfunction or destruction. The rectangular box is assumed power/ground planes and its internal field is calculated by the cavity model with the lightning strike excitation as an HPEM pulse. The accuracy of the calculation method employed here is validated through a $156mm{\times}106mm{\times}508{\mu}m$ parallel metallic plate case which is manufactured and tested, and is applied to the size of a building. With the help of the cavity model that takes into account loading, the level of the electric field is shown to decrease when a metal pillar is loaded between the power and ground planes.

A Case Study on the Analysis of Soft Ground Consolidation by the Measurement of Surface Settlement Plate (지표침하판계측을 통한 연약지반 침하분석 사례연구)

  • Kim, Joon-Seok
    • Journal of Urban Science
    • /
    • 제9권2호
    • /
    • pp.51-56
    • /
    • 2020
  • The installation of soft ground instruments and the performance of measurement and management of the measurement shall be carried out in order to ensure the safety of the construction work and to improve the quality of the construction work. The purpose of the pressure density deposition calculation is to determine the stability of the foundation ground and the formulation by measuring and calculating the density conditions generated on the soil through the period of neglect after completion of the soil at each stage. In practice, it is judged that the analysis by the hyperbolic method can be applied to the safety side.

An Analysis of the Farm Silo Supported by Ground (지반과 구조물 사이의 상호작용을 고려한 농업용 사이로의 해석에 관한 연구 (III) - 제3보 상대강성의 영향 -)

  • 조진구;조형영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제29권2호
    • /
    • pp.39-52
    • /
    • 1987
  • This study was to investigate the effects of soil-structure relative stiffness on the structural characteristics of the cylindrical tank supported by soil. A standard example model of the farm silo rested on the Winkler's subsoil model was used for the analysis of soil-structure coupled system. In this paper, Winkler's constants 4,15 and l00kg/cm$^2$/cm were considered and the bottom plate thicknesses of the farm silo 20, 30, 50,100 and 150cm were adopted. For the given model the effects of bottom plate thickness were the most conspicuous at weakest Winkler's constant 4kg/ cm$^2$/cm. While when Winkler's constant is l00kg/cm$^2$/cm, the effect of the bottom plate thickness is almost negligible. On the other hand, when the bottom plate thickness is more than 100cm, the effects of elastic foundation were aknost disappeared. In design practice, it is hoped that the thicknesses of bottom plate should be determined reasonably because of it's considerable effect on the structural characteristics as the lOOcm thickness of bottom plate will not be practical value in usual sites.

  • PDF